Skip to main content
Log in

Development of a Radiotherapy System Based on 6 MeV Linac and Cone-Beam Computer Tomograph

  • Published:
Atomic Energy Aims and scope

A Correction to this article was published on 01 September 2019

This article has been updated

A system currently under development for remote radiotherapy based on a 6 MeV linac and cone-beam computer tomograph is presented. Its distinguishing design features and solutions are described: compact 5-cm wavelength electron accelerator, solid-state modulator, visualization in the bremsstrahlung beam with low nominal energy 2.5 MeV, bremsstrahlung beam without a compensating filter, cone-beam computer tomography, multi-leaf collimator, adaptive radiotherapy, and a therapeutic table with six degrees of freedom. The system is compared with foreign analogs.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Change history

  • 08 November 2019

    The 15th author’s name should read I. A. Gulidov.

    The caption for Fig. 3 on page 336 should read

References

  1. E. V. Khmelevskii and A. D. Kaprin, “Status of radiotherapeutic work in Russia: comparative analysis and prospects for development,” Onkologiya. Zh. im. Gertsena, 6, No. 4, 38–41 (2017), https://doi.org/10.17116/onkolog.20176438-41.

    Article  Google Scholar 

  2. L. Yu. Ovchinnikova and V. I. Shvedunov, “Design of C-band electron linear accelerator for a complex of radiation therapy,” in: 29th Linear Accelerator Conf. LINAC18, TUPO097 China, Beijing, http://linac2018.vrws.de/papers/tupo097.pdf.

  3. D. S. Yurov, L. Yu. Ovchinnikova, A. S. Alimov, et al., “Beam parameters measurement of C-band 6 MeV linear electron accelerator,” ibid., http://linac2018.vrws.de/papers/ mopo061.pdf.

  4. A. N. Ermakov, A. S. Alimov, L. Yu. Ovchinnikova, et al., “Linacs for industry, cargo inspection and medicine designed by Moscow University,” ibid., http://linac2018.vrws.de/papers/mopo060.pdf.

  5. UNIQUE . The Complete Radiation Oncology Solution. Specifications, VEO OS 1050I, Varian Med. Syst. Int. AG, Cham, Switzerland (2016).

  6. Elekta Compact TM. Product Data, Art. No. 4513 371 0755, Elekta AB, Stockholm, Sweden.

  7. Elekta Compact TM. Site Planning Guide, No. 1005521 03, Elekta AB, Stockholm, Sweden, 11/2010.

Download references

Author information

Authors and Affiliations

Authors

Additional information

Translated from Atomnaya Énergiya, Vol. 125, No. 5, pp. 292–295, November, 2018.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Rod’ko, I.I., Sarychev, G.A., Balakirev, P.V. et al. Development of a Radiotherapy System Based on 6 MeV Linac and Cone-Beam Computer Tomograph. At Energy 125, 333–337 (2019). https://doi.org/10.1007/s10512-019-00490-9

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10512-019-00490-9

Navigation