Na18F accumulates on the compressive side of peri-implant bone under immediate loading

  • Original Article
  • Published:
Odontology Aims and scope Submit manuscript

Abstract

This study aimed to examine the dynamic change in bone metabolism by immediate loading in several sites around implants using high-resolution Na18F-PET scan. Two titanium implants (Ø 1.2 mm) were inserted parallel to each other in the right tibiae of Wistar rats (n = 4). The left tibia was set as control side. One day after insertion, closed coil springs of 4.0 N were attached to the expose superior portions of the implants to apply a continuous mechanical stress. The rats with fluorine-18 (18F) ion (5 mCi/rat) intravenously injected were scanned by PET scanner at 4, 7, 14, 28 days after load application. Round region of interests (ROIs) were set around the distal implant of the right tibia (loaded side) and same site (control) of the left tibia. Furthermore, four rectangular ROIs were set at the superior and inferior parts of traction side (mesial) and opposite side (distal) of the distal implant. Longitudinal dynamic changes in bone metabolism were evaluated by examination of the accumulation count of 18F ion at each ROI. The uptake values of ROIs (loaded side) initially increased until 7 days, and they gradually decreased from the peak level to the pre-loading level despite a static force being applied to the implants. In cancellous bone, the uptake values at the superior part of traction side and inferior part of opposite side showed significantly high value compared with those at other parts. In conclusion, immediate loading to the implant initially enhanced bone metabolism around it, especially at the part with compressive stress. Peri-implant bone metabolism varies according to different loading conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Weber HP, Morton D, Galluci GO, Roccuzzo M, Cordaro L, Grutter L. Consensus statements and recommended clinical procedures regarding loading protocols. Int J Oral Maxillofac Implants. 2009;24:180–3.

    PubMed  Google Scholar 

  2. Esposito M, Grusovin MG, Maghaireh H, Worthington HV. Interventions for replacing missing teeth: different times for loading dental implants. Cochrane Database Syst Rev. 2013;28(3):CD003878.

    Google Scholar 

  3. Alsabeeha N, Atieh M, Payne AG. Loading protocols for mandibular implant overdentures: a systematic review with meta-analysis. Clin Implant Dent Relat Res. 2010;12:e28–38.

    Article  PubMed  Google Scholar 

  4. Javed F, Romanos GE. The role of primary stability for successful immediate loading of dental implants. A literature review J Dent. 2010;38:612–20.

    PubMed  Google Scholar 

  5. Yoda N, Zheng K, Chen J, Li W, Swain M, Sasaki K, Li Q. Bone morphological effects on post-implantation remodeling of maxillary anterior buccal bone: a clinical and biomechanical study. J Prosthodont Res. 2017;61(4):393–402. https://doi.org/10.1016/j.jpor.2016.12.010.

    Article  PubMed  Google Scholar 

  6. Ogawa T, Zhang X, Naert I, Vermaelen P, Deroose CM, Sasaki K, et al. The effect of whole-body vibration on peri-implant bone healing in rats. Clin Oral Implants Res. 2011;22:302–7.

    Article  PubMed  Google Scholar 

  7. Hoh CK, Hawkins RA, Dahlbom M, Glaspy JA, Seeger LL, Choi Y, et al. Whole body skeletal imaging with [18F] fluoride ion and PET. J Comput Assist Tomogr. 1993;17:34–41.

    Article  PubMed  Google Scholar 

  8. Blau M, Ganatra R, Bender MA. 18F-fluoride for bone imaging. Semin Nucl Med. 1972;2:31–7.

    Article  PubMed  Google Scholar 

  9. Grant FD, Fahey FH, Packard AB, Davis RT, Alavi A, Treves ST. Skeletal PET with 18F-fluoride: applying new technology to an old tracer. J Nucl Med. 2008;49:68–78.

    Article  PubMed  Google Scholar 

  10. Ishii K, Kikuchi Y, Matsuyama S, Kanai Y, Kotani K, Ito T, et al. First achievement of less than 1 mm FWHM resolution in practical semiconductor animal PET scanner. Nucl Instrum Methods Phys Res A. 2007;576:435–40.

    Article  Google Scholar 

  11. Matsuo Y, Ogawa T, Yamamoto M, Shibamoto A, Sáenz JR, Yokoyama M, et al. Evaluation of peri-implant bone metabolism under immediate loading using high-resolution Na18F-PET. Clin Oral Investig. 2017;21:2029–37.

    Article  PubMed  Google Scholar 

  12. Yamamoto M, Ogawa T, Tokoyama M, Koyama S, Sasaki K. Influence of immediate and early loading on bone metabolic activity around dental implants in rat tibiae. Clin Oral Impl Res. 2014;25:1084–90.

    Article  Google Scholar 

  13. Gentleman E, Stevens MM, Hill RG, Brauer DS. Surface properties and ion release from fluoride-containing bioactive glasses promote osteoblast differentiation and mineralization in vitro. Acta Biomater. 2013;9:5771–9.

    Article  PubMed  Google Scholar 

  14. Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging. 1982;1:113–22.

    Article  PubMed  Google Scholar 

  15. Bambini F, Memè L, Procaccini M, Rossi B, LO Muzio L. Bone scintigraphy and SPECT in the evaluation of the osseointegrative response to immediate prosthetic loading of endosseous implants: a pilot study. Int J Oral Maxillofac Implants. 2004;19:80–6.

    PubMed  Google Scholar 

  16. Yokohama M, Atsumi T, Tsuchiya M, Koyama S, Sasaki K. Dynamic changes in bone metabolism in the rat temporomandibular joint after molar extraction using bone scintigraphy. Eur J Oral Sci. 2009;117:374–9.

    Article  Google Scholar 

  17. Suenaga H, Yokohama M, Yamaguchi K, Sasaki K. Bone metabolism of residual ridge beneath the denture base of an RPD observed using NaF-PET/CT. J Prosthodont Res. 2012;56:42–6.

    Article  PubMed  Google Scholar 

  18. Temmerman OP, Raijmakers PG, Heyligers IC, Comans EF, Lubberink M, Teule GJ, et al. Bone metabolism after total hip revision surgery with impacted grafting: evaluation using H 152 O and [18F] fluoride PET; a pilot study. Mol Imaging Biol. 2008;10:288–93.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Sasaki H, Koyama S, Yokoyama M, Yamaguchi K, Itoh M, Sasaki K. Bone metabolic activity around dental implants under loading observed using bone scintigraphy. Int J Oral Maxillofac Implants. 2008;23:827–34.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Toru Ogawa.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Funding

This work was partially supported by Grants-in-Aid for Scientific Research (B) (Grant no. 24390428), Grant-in-Aid for Young Scientists (B) (Grant no. 24792130, 26861620) from the Ministry of Education, Culture, Sports, Science and Technology, Japan.

Ethical approval

This article does not contain any studies with human participants. Ethical approval (2012CrA-4) was provided by the Institutional Animal Use and Care Committee of Tohoku University.

Informed consent

For this type of study, formal consent is not required.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yamamoto, M., Ogawa, T., Yokoyama, M. et al. Na18F accumulates on the compressive side of peri-implant bone under immediate loading. Odontology 106, 232–237 (2018). https://doi.org/10.1007/s10266-017-0327-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10266-017-0327-0

Keywords

Navigation