Skip to main content
Log in

Initial experience of EVAHEART explantation after continuous-flow LVAD off test with percutaneous occlusion balloon

  • Case Report
  • Artificial Heart (Clinical)
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

In contrast to a pulsatile-flow left ventricular assist device (LVAD), an LVAD off test for evaluation of cardiac recovery with a continuous-flow device is difficult because of intra-circuit backflow from the outflow graft when a device is stopped. We report a case of reliable evaluation of cardiac recovery using balloon occlusion of the outflow graft, followed by successful removal of a continuous-flow EVAHEART LVAD using a minimally invasive approach.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Kato TS, Chokshi A, Singh P, Khawaja T, Cheema F, Akashi H, et al. Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling. Circ Heart Fail. 2011;4(5):546–53.

    Article  PubMed Central  PubMed  Google Scholar 

  2. Yoshioka D, Toda K, Sakaguchi T, Miyagawa S, Nishi H, Yoshikawa Y, Fukushima S, et al. Initial report of bridge to recovery in a patient with DuraHeart LVAD. J Artif Organs. 2013;16(3):386–8.

    Article  PubMed  Google Scholar 

  3. Ando M, Nishimura T, Takewa Y, Ogawa D, Yamazaki K, Kashiwa K, et al. What is the ideal off-test trial for continuous-flow ventricular-assist-device explantation? Intracircuit back-flow analysis in a mock circulation model. J Artif Organs. 2011;14:70–3.

    Article  PubMed  Google Scholar 

  4. Potapov EV, Schweiger M, Krabatsch T. Percutaneous balloon occlusion of a left ventricular assist device outflow cannula to facilitate evaluation of myocardial recovery. J Heart Lung Transplant. 2011;30(11):1300–1.

    Article  PubMed  Google Scholar 

  5. Haj-Yahia S, Birks EJ, Dreyfus G, Khaghani A. Limited surgical approach for explanting the HeartMate II left ventricular assist device after myocardial recovery. J Thorac Cardiovasc Surg. 2008;135:453–4.

    Article  CAS  PubMed  Google Scholar 

Download references

Conflict of interest

The authors have no conflict of interest to declare.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoshiki Sawa.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kashiyama, N., Toda, K., Miyagawa, S. et al. Initial experience of EVAHEART explantation after continuous-flow LVAD off test with percutaneous occlusion balloon. J Artif Organs 17, 366–369 (2014). https://doi.org/10.1007/s10047-014-0784-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-014-0784-y

Keywords

Navigation