Entry zone of iliac screw fixation to maintain proper entry width and screw length

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Purpose

To evaluate the entry zone of iliac screw fixation to maintain proper entry width and screw length.

Methods

Computed tomography images of pelvic bones from 90 human cadavers were reconstructed into 3-dimensional models. In each model, a sectional image crossing the posterior superior iliac spine (PSIS) and anterior inferior iliac spine (AIIS) and consecutive sectional images up to 20 mm superiorly and inferiorly from the PSIS with 1-mm intervals aiming the AIIS were obtained. One virtual iliac screw with 10-mm diameter was introduced onto the PSIS at the middle and at the lateral and medial 1/4 points on the prominence of the posterior iliac spine. The entry width of the bony prominence and the corresponding maximal screw length available were evaluated for each entry point.

Results

The entry width was smallest on the inferior 20 mm (4.7 ± 3.0 mm) and gradually increased up to the superior 10 mm (19.1 ± 3.9 mm) sectional images. The maximal screw length was smallest on the superior 20 mm (76.7 ± 39.7 mm) and gradually increased down to the inferior 10 mm (112.3 ± 15.1 mm) sectional images. The maximal screw lengths were significantly greatest at the most medial point and smallest at the most lateral point on the superior 20- and 10-mm sectional images and at the PSIS.

Conclusions

The iliac screw fixation entry zone to maintain proper screw length and entry width is outlined from 20 mm superiorly to 10 mm inferiorly from the PSIS and is located more medially from the prominence of the posterior iliac spine.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Kasten MD, Rao LA, Priest B (2010) Long-term results of iliac wing fixation below extensive fusions in ambulatory adult patients with spinal disorders. J Spinal Disord Tech 23:e37–e42. doi:10.1097/BSD.0b013e3181cc8e7f

    Article  PubMed  Google Scholar 

  2. Harrop JS, Jeyamohan SB, Sharan A, Ratliff J, Vaccaro AR (2009) Iliac bolt fixation: an anatomic approach. J Spinal Disord Tech 22:541–544. doi:10.1097/BSD.0b013e31818da3e2

    Article  PubMed  Google Scholar 

  3. O’Shaughnessy BA, Lenke LG, Bridwell KH, Cho W, Zebala LP, Chang MS, Auerbach JD, Crawford CH, Koester LA (2012) Should symptomatic iliac screws be electively removed in adult spinal deformity patients fused to the sacrum? Spine 37:1175–1181. doi:10.1097/Brs.0b013e3182426970

    Article  PubMed  Google Scholar 

  4. Shen FH, Mason JR, Shimer AL, Arlet VM (2013) Pelvic fixation for adult scoliosis. Eur Spine J 22(Suppl 2):S265–S275. doi:10.1007/s00586-012-2525-3

    Article  PubMed  Google Scholar 

  5. Schildhauer TA, McCulloch P, Chapman JR, Mann FA (2002) Anatomic and radiographic considerations for placement of transiliac screws in lumbopelvic fixations. J Spinal Disord Tech 15:199–205 (discussion 205)

    Article  PubMed  Google Scholar 

  6. O’Brien JR, Matteini L, Yu WD, Kebaish KM (2010) Feasibility of minimally invasive sacropelvic fixation: percutaneous S2 alar iliac fixation. Spine (Phila Pa 1976) 35:460–464. doi:10.1097/BRS.0b013e3181b95dca

    Article  Google Scholar 

  7. Tian X, Li J, Sheng W, Qu D, Ouyang J, Xu D, Chen S, Ding Z (2010) Morphometry of iliac anchorage for transiliac screws: a cadaver and CT study of the Eastern population. Surg Radiol Anat 32:455–462. doi:10.1007/s00276-009-0589-5

    Article  PubMed  Google Scholar 

  8. Wang MY, Williams S, Mummaneni PV, Sherman JD (2012) Minimally invasive percutaneous iliac screws: initial 24 case experience with CT confirmation. J Spinal Disord Tech. doi:10.1097/BSD.0b013e3182733c43

    PubMed Central  Google Scholar 

  9. Wang MY (2012) Percutaneous iliac screws for minimally invasive spinal deformity surgery. Minim Invasive Surg 2012:173685. doi:10.1155/2012/173685

    PubMed Central  PubMed  Google Scholar 

  10. Schünke M, Schulte E, Schumacher U (2014) Thieme atlas of anatomy. General anatomy and musculoskeletal system. Thieme Medical Publishers Inc, New York

    Google Scholar 

  11. Chapman JR, Harrington RM, Lee KM, Anderson PA, Tencer AF, Kowalski D (1996) Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 118:391–398

    Article  CAS  PubMed  Google Scholar 

  12. Cunningham BW, Lewis SJ, Long J, Dmitriev AE, Linville DA, Bridwell KH (2002) Biomechanical evaluation of lumbosacral reconstruction techniques for spondylolisthesis: an in vitro porcine model. Spine 27:2321–2327. doi:10.1097/01.BRS.0000030852.79881.F1

    Article  PubMed  Google Scholar 

  13. Tis JE, Helgeson M, Lehman RA, Dmitriev AE (2009) A biomechanical comparison of different types of lumbopelvic fixation. Spine 34:E866–E872. doi:10.1097/BRS.0b013e3181bf94f0

    Article  PubMed  Google Scholar 

  14. Chen H, Yu BS, Zheng ZM, Lu Y, Zhang KB, Liu H, Li FB (2008) Biomechanical effect of the iliac screw insertion depth on lumbo-iliac fixation construct. Zhonghua wai ke za zhi [Chin J Surg] 46:1179–1182

    Google Scholar 

  15. Zheng ZM, Yu BS, Chen H, Aladin DM, Zhang KB, Zhang JF, Liu H, Luk KD, Lu WW (2009) Effect of iliac screw insertion depth on the stability and strength of lumbo-iliac fixation constructs: an anatomical and biomechanical study. Spine 34:E565–E572. doi:10.1097/BRS.0b013e3181ac8fc4

    Article  PubMed  Google Scholar 

  16. Dayer R, Ouellet JA, Saran N (2012) Pelvic fixation for neuromuscular scoliosis deformity correction. Curr Rev Musculoskelet Med 5:91–101. doi:10.1007/s12178-012-9122-2

    Article  PubMed Central  PubMed  Google Scholar 

  17. Yu BS, Zhuang XM, Zheng ZM, Li ZM, Wang TP, Lu WW (2010) Biomechanical advantages of dual over single iliac screws in lumbo-iliac fixation construct. Eur Spine J 19:1121–1128. doi:10.1007/s00586-010-1343-8

    Article  PubMed Central  PubMed  Google Scholar 

  18. Schildhauer TA, McCulloch P, Chapman JR, Mann FA (2002) Anatomic and radiographic considerations for placement of transiliac screws in lumbopelvic fixations. J Spinal Disord Tech 15:199–205 (discussion 205)

    Article  PubMed  Google Scholar 

  19. Day AC, Stott PM, Boden RA (2007) The accuracy of computer-assisted percutaneous iliosacral screw placement. Clin Orthop Relat Res 463:179–186

    PubMed  Google Scholar 

Download references

Acknowledgments

This research was partially supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (NRF-2013R1A1A1009600).

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dai-Soon Kwak.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Park, SA., Kwak, DS. & You, SL. Entry zone of iliac screw fixation to maintain proper entry width and screw length. Eur Spine J 24, 2573–2579 (2015). https://doi.org/10.1007/s00586-015-4042-7

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-015-4042-7

Keywords

Navigation