Abstract
Odontoid fracture fixation allows for early mobilisation out of orthosis. Both anterior and posterior fixation techniques have been described but anterior surgery has less post-operative morbidity through the use of natural cleavage planes. We described the use of anterior transarticular stabilisation as a salvage procedure following a failed odontoid screw fixation.
Similar content being viewed by others
References
Huybregts JG, Jacobs WC, Vleggeert-Lankamp CL (2013) The optimal treatment of type II and III odontoid fractures in the elderly: a systematic review. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc 22(1):1–13 (Epub 2012/09/04)
Anderson LD, D’Alonzo RT (1974) Fractures of the odontoid process of the axis. J Bone Joint Surg Am Vol 56(8):1663–1674 (Epub 1974/12/01)
Grauer JN, Shafi B, Hilibrand AS, Harrop JS, Kwon BK, Beiner JM et al (2005) Proposal of a modified, treatment-oriented classification of odontoid fractures. Spine J Off J N Am Spine Soc 5(2):123–129 (Epub 2005/03/08)
Pal D, Sell P, Grevitt M (2011) Type II odontoid fractures in the elderly: an evidence-based narrative review of management. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc 20(2):195–204 (Epub 2010/09/14)
Gallie WE (1937) Skeletal traction in the treatment of fractures and dislocations of the cervical spine. Ann Surg 106(4):770–776 (Epub 1937/10/01)
Magerl F, Seeman PS (1986) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A (eds) Cervical spine. Springer, Wien, pp 267–278
Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129(1–2):47–53 (Epub 1994/01/01)
Harms J, Melcher RP (2001) Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine 26(22):2467–2471 (Epub 2001/11/15)
Bohler J (1982) Anterior stabilization for acute fractures and non-unions of the dens. J Bone Jt Surg Am Vol 64(1):18–27 (Epub 1982/01/01)
Sasso R, Doherty BJ, Crawford MJ, Heggeness MH (1993) Biomechanics of odontoid fracture fixation. Comparison of the one- and two-screw technique. Spine 18(14):1950–1953 (Epub 1993/10/15)
McBride AD, Mukherjee DP, Kruse RN, Albright JA (1995) Anterior screw fixation of type II odontoid fractures. A biomechanical study. Spine 20(17):1855–1859 (discussion 9–60) (Epub 1995/09/01)
Jenkins JD, Coric D, Branch CL Jr (1998) A clinical comparison of one- and two-screw odontoid fixation. J Neurosurg 89(3):366–370 (Epub 1998/09/02)
Chapman J, Smith JS, Kopjar B, Vaccaro AR, Arnold P, Shaffrey CI et al (2013) The AOSpine North America Geriatric Odontoid Fracture Mortality Study: a retrospective review of mortality outcomes for operative versus nonoperative treatment of 322 patients with long-term follow-up. Spine. 38(13):1098–1104 (Epub 2013/01/29)
Andersson S, Rodrigues M, Olerud C (2000) Odontoid fractures: high complication rate associated with anterior screw fixation in the elderly. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc 9(1):56–59 (Epub 2000/04/15)
Sen MK, Steffen T, Beckman L, Tsantrizos A, Reindl R, Aebi M (2005) Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc 14(5):512–518 (Epub 2005/01/26)
Josten C, Jarvers J, Riesner H, Franck A, Glasmacher S, Schmidt C (2012) 3 year results of the anterior transarticular c1-2 fusion in atlanto-axial instabilities of elder patients. J Bone Joint Surg Br 94-B(SUPP XXXVII):386
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Salem, K.M.I., Collins, I. & Boszczyk, B.M. Salvage of failed odontoid fixation through anterior C1/C2 transarticular screws. Eur Spine J 24, 609–614 (2015). https://doi.org/10.1007/s00586-015-3756-x
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00586-015-3756-x