Skip to main content
Log in

Atlantoaxial fusion using anterior transarticular screw fixation of C1–C2: technical innovation and biomechanical study

  • Technical Innovation
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

This study is an attempt to describe a new technique for anterior transarticular screw fixation of the atlantoaxial joints, and to compare the stability of this construct to posterior transarticular screw fixation with and without laminar cerclage wiring. Nine human cadaveric specimens were included in this study. The C1–C2 motion segment was instrumented using either anterior transarticular screws (group 1), posterior transarticular screws alone (group 2), or posterior screws with interlaminar cerclage wires (group 3). Using an unconstrained mechanical testing machine, the specimens were tested in rotation, lateral bending, and flexion-extension using nondestructive loads of ±2 N m. The specimens were also tested in translation using nondestructive loads of ±100 N. All values for the three groups with regards to anterior-posterior displacement, rotation, and lateral bending were similar as determined using a Kruskal–Wallis rank sum test with a significance level of p<0.05. The only significant difference was registered in flexion-extension where the cerclage wire added some strength to the construct. Anterior transarticular screw fixation of the atlantoaxial spine has several advantages over posterior fixation techniques, and is as stable as posterior transarticular fixation in all clinically significant planes of motion. The addition of posterior interlaminar cerclage wiring further improves resistance to flexion-extension forces. Anterior transarticular screw fixation of the atlantoaxial joint is a useful technique for achieving C1–C2 stabilization.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Aebi M, Etter C, Coscia M (1989) Fractures of the odontoid process: treatment with anterior screw fixation. Spine 14:1065–1070

    Google Scholar 

  2. Aldrich EF, Weber PB (1993) Halifax interlaminar clamp for posterior cervical fusion: a long term follow-up review. J Neurosurg 74:185–189

    Google Scholar 

  3. Alexander E Jr, Forsyth HF, Davis CH Jr., Nashold BS (1958) Dislocation of the atlas and axis, the value of early fusion of C1, C2, and C3. J Neurosurg 15:353–371

    Google Scholar 

  4. Brooks AL, Jenkins EB (1978) Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 60:279–284

    Google Scholar 

  5. Clark CR, Devon GD, Menezes AH (1989) Arthrodesis of the cervical spine in rheumatoid arthritis. J Bone Joint Surg Am 71:381–392

    Google Scholar 

  6. Coyne TJ, Fehlings MG, Wallace MC, Bernstein M, Tator C (1995) C1-C2 posterior cervical fusion: long-term evaluation of results and efficacy. Neurosurgery 37(4):688–693

    Google Scholar 

  7. Dunbar HS, Ray BS (1961) Chronic atlanto-axial dislocations with late neurologic manifestations. Surg Gynec Obstet 113:757–762

    Google Scholar 

  8. Dvorak M, Sekeramayi F, Zhu Q, Hoekema J, Fisher C, Boyd M, Goertzen D, Oxland T (2003) Anterior occiput to axis screw fixation, part II: a biomechanical comparison with posterior fixation techniques. Spine 28:239–245

    Article  Google Scholar 

  9. Etter C, Coscia M, Jaberg H, Aebi M (1991) Direct anterior fixation of Dens fractures with a cannulated screw system. Spine 16[Suppl]:S25–S32

    Google Scholar 

  10. Farey ID, Nadkarni S, Smith N (1999) Modified Gallie technique versus transarticular screw fixation in C1-C2 fusion. Clin Orthop 359:126–35

    Google Scholar 

  11. Fielding JW, Hawkins RJ, Ratzan SA (1976) Spine fusion for atlanto-axial instability. J Bone Joint Surg Am 58:400–407

    CAS  PubMed  Google Scholar 

  12. Fried LC (1973) Atlanto-axial fracture dislocations. J Bone Joint Surg Br 55:490–496

    Google Scholar 

  13. Gallie WE (1939) Fractures and dislocations of the cervical spine. Am J Surg 46:495–499

    Article  Google Scholar 

  14. Griswold DM, Albright JA, Schiffman E, Johnson R, Southwick SO (1992) Atlanto-axial fusion for instability. J Bone Joint Surg Am 60:285–292

    Google Scholar 

  15. Grob D, Jeanneret B, Aebi M, Markwalder T-M (1991) Atlantoaxial fusion with transarticular screw fixation. J Bone Joint Surg Br 73:972–976

    Google Scholar 

  16. Grob D, Crisco JJ, Panjabi MM, Wang P, Dvorak J (1992) Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine 17(5):480–490

    CAS  PubMed  Google Scholar 

  17. Guiot B, Fessler RG (1999) Complex atlantoaxial fractures. J Neurosurg: Spine 91:139–143

    Google Scholar 

  18. Hanson PB, Pasquale MX, Sharkey NA, Rauschning W (1991) Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability. Spine 16:1141–1145

    Google Scholar 

  19. Hoppenfeld S, deBoer P (1994) Surgical exposures in orthopaedics. Lippincott, Philadelphia

    Google Scholar 

  20. Kandziora F, Kerschbaumer F, Starker M, Nittlmeier T (2000) Biomechanical assessment of transoral plate fixation for atlantoaxial Instability. Spine 25: 1555–1561

    Article  CAS  PubMed  Google Scholar 

  21. Lesoin F, Autrique A, Franz K, Villette L, Jomin M (1987) Transcervical approach and screw fixation for upper cervical spine pathology. Surg Neurol 27:459–465

    Article  Google Scholar 

  22. Madawi AA, Solanki G, Casey AT, Crockard HA (1997) Variation of the groove in the axis vertebra for the vertebral artery: implications for instrumentation. J Bone Joint Surg Br 79:820–823

    Article  PubMed  Google Scholar 

  23. Magerl F, Seeman PS (1986) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A (eds) Cervical spine. Springer, Berlin Heidelberg New York, pp 322–327

    Google Scholar 

  24. Mandel IM, Kambach BJ, Petersilge CA, Johnstone B, Yoo JU (2000) Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws. Spine 25:1542–1547

    Article  Google Scholar 

  25. McGuire RA, Harkey HL (1995) Modification of technique and results of atlantoaxial transfacet stabilization. Orthopedics 18:1029–1032

    Google Scholar 

  26. Mitchell TC, Sadasivan KK, Ogden AL, Mayeux RH, Mukherjee DP, Albright JA (1999) Biomechanical study of atlantoaxial arthrodesis: transarticular screw fixation versus modified Brooks posterior wiring. J Orthop Trauma 13:483–489

    Article  Google Scholar 

  27. Montesano PX, Juach EC, Anderson PA, Benson DR, Hanson PB (1991) Biomechanics of cervical spine internal fixation. Spine 16[Suppl]:s10–s16

    Google Scholar 

  28. Naderi S, Crawford NR, Song GS, Sonntag VKH, Dickman CA (1998) Biomechanical comparisons of C1-C2 posterior fixations. Spine 23:1946–1956

    Article  Google Scholar 

  29. Panjabi MM, Abumi K, Duranceau J, Crisco JJ (1988) Biomechanical evaluation of spinal fixation devices, II: stability provided by eight internal fixation devices. Spine 13:1135–1140

    Google Scholar 

  30. Paramore CG, Dickman CA, Sonntag VK (1996) The anatomic suitability of the C1-C2 complex for transarticular screw fixation. J Neurosurg 85:221–224

    Google Scholar 

  31. Reindl R, Sen M, Aebi M (2003) Anterior instrumentation for traumatic C1-C2 instability. Spine 28:E329–E333

    Article  Google Scholar 

  32. Schlesinger EB, Taveras JM (1958) Lesions of the odontoid and their management. Am J Surg 95:641–648

    Article  Google Scholar 

  33. Sherk HH, Snyder B (1978) Posterior fusions of the upper cervical spine: indications, techniques, and prognosis. Orthop Clin North Am 9:1091–1099

    CAS  PubMed  Google Scholar 

  34. Simmons EH, Dutoit G (1978) Lateral atlantoaxial arthrodesis. Orthop Clin North Am 9:1101–1114

    Google Scholar 

  35. Statham P, O’Sullivan M, Russell T (1993) The halifax interlaminar clamp for posterior cervical fusion: initial experience in the United Kingdom. Neurosurgery 32:396–399

    Google Scholar 

  36. Stillerman CB, Wilson JA (1993) Altanto-axial stabilization with posterior transarticular screw fixation: technical description and report of 22 cases. Neurosurgery 32:948–955

    Google Scholar 

  37. Vaccaro AR, Lehman AP, Ahlgren BD, Garfin SR (1999) Anterior C1-C2 screw fixation and bony fusion through an anterior retropharyngeal approach. Orthopedics 22:1165–1170

    Google Scholar 

  38. White A, Panjabi MM (1990) Clinical biomechanics of the spine. Lippincott, Philadelphia

    Google Scholar 

  39. Wilke HJ, Fischer K, Kugler A, Magerl F, Claes L, Worsdorfer O (1992) In vitro investigations of internal fixation systems of the upper cervical spine, II: stability of posterior atlanto-axial fixation techniques. Eur Spine J 1:191–199

    Article  Google Scholar 

  40. Wright NM, Lauryssen C (1998) Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. J Neurosurg 88:634–640

    Google Scholar 

  41. Yang K, Steffen T (2000) Harvesting the intact cadaveric cervical spine. Spine 25:1447–1449

    Article  Google Scholar 

Download references

Acknowledgements

Tara Swanson for technical assistance; Synthes Canada for supplying implants.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Milan K. Sen.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sen, M.K., Steffen, T., Beckman, L. et al. Atlantoaxial fusion using anterior transarticular screw fixation of C1–C2: technical innovation and biomechanical study. Eur Spine J 14, 512–518 (2005). https://doi.org/10.1007/s00586-004-0823-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-004-0823-0

Keywords

Navigation