Abstract
Purpose
The aim of this study was to follow a group of skeletally immature patients who received arthroscopy-assisted fixation of the displaced tibial eminence fractures with suture anchors and evaluate the clinical results.
Methods
Twenty-one pediatric patients with displaced tibial eminence fractures were enrolled in this retrospectively study. They received arthroscopy-assisted reduction and fixation using suture anchors. All cases were followed up for 40–47 months with a mean of 43.4 months. Follow-up examinations included radiographic assessment, Lysholm score, Tegner score, International Knee Documentation Committee (IKDC) rating scale and KT-1000 test.
Result
Twenty patients were available for our final evaluations. They improved significantly at the final follow-up compared with preoperative examinational results with respect to the results of radiographic assessment, Lysholm score, Tegner score, IKDC rating scale and KT-1000 test.
Conclusion
Arthroscopy-assisted reduction and fixation of the displaced tibial eminence fractures using suture anchors is a simple and reliable technique and is suitable for skeletally immature patients.
Similar content being viewed by others
References
Shin YW, Uppstrom TJ, Haskel JD et al (2015) The tibial eminence fracture in skeletally immature patients[J]. Curr Opin Pediatr 27(1):50–57
Kocher MS, Mandiga R, Klingele K et al (2004) Anterior cruciate ligament injury versus tibial spine fracture in the skeletally immature knee: a comparison of skeletal maturation and notch width index[J]. J Pediatr Orthop 24(2):185–188
Reynders P, Reynders K, Broos P (2002) Pediatric and adolescent tibial eminence fractures: arthroscopic cannulated screw fixation[J]. J Trauma Acute Care Surg 53(1):49–54
Meyers MH, McKEEVER FM (1970) Fracture of the intercondylar eminence of the tibia[J]. J Bone Jt Surg Am 52(8):1677–1684
Zaricznyj B (1977) Avulsion fracture of the tibial eminence: treatment by open reduction and pinning[J]. J Bone Jt Surg Am 59(8):1111–1114
Osti L, Buda M, Soldati F et al (2016) Arthroscopic treatment of tibial eminence fracture: a systematic review of different fixation methods[J]. Br Med Bull 118(1):73–90
Delcogliano A, Chiossi S, Caporaso A et al (2003) Tibial intercondylar eminence fractures in adults: arthroscopic treatment[J]. Knee Surg Sports Traumatol Arthrosc 11(4):255–259
Tudisco C, Giovarruscio R, Febo A et al (2010) Intercondylar eminence avulsion fracture in children: long-term follow-up of 14 cases at the end of skeletal growth[J]. J Pediatr Orthopaed B 19(5):403–408
Vander Have KL, Ganley TJ, Kocher MS et al (2010) Arthrofibrosis after surgical fixation of tibial eminence fractures in children and adolescents[J]. Am J Sports Med 38(2):298–301
Coyle C, Jagernauth S, Ramachandran M (2014) Tibial eminence fractures in the paediatric population: a systematic review[J]. J Child Orthop 8(2):149–159
Hapa O, Barber FA, Süner G et al (2012) Biomechanical comparison of tibial eminence fracture fixation with high-strength suture, EndoButton, and suture anchor[J]. Arthrosc J Arthrosc Relat Surg 28(5):681–687
Lysholm J, Gillquist J (1982) Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale[J]. Am J Sports Med 10(3):150–154
Tegner Y, Lysholm J (1985) Rating systems in the evaluation of knee ligament injuries[J]. Clin Orthop Relat Res 198:42–49
Hefti E, Müller W, Jakob RP et al (1993) Evaluation of knee ligament injuries with the IKDC form[J]. Knee Surg Sports Traumatol Arthrosc 1(3–4):226–234
Watts CD, Larson AN, Milbrandt TA (2016) Open versus arthroscopic reduction for tibial eminence fracture fixation in children[J]. J Pediatr Orthopaed 36(5):437–439
Matthews DE, Geissler WB (1994) Arthroscopic suture fixation of displaced tibial eminence fractures[J]. Arthrosc J Arthrosc Relat Surg 10(4):418–423
Seon JK, Park SJ, Lee KB et al (2009) A clinical comparison of screw and suture fixation of anterior cruciate ligament tibial avulsion fractures[J]. Am J Sports Med 37(12):2334–2339
Lubowitz JH, Elson WS, Guttmann D (2005) Part II: arthroscopic treatment of tibial plateau fractures: intercondylar eminence avulsion fractures[J]. Arthrosc J Arthrosc Relat Surg 21(1):86–92
Bong MR, Romero A, Kubiak E et al (2005) Suture versus screw fixation of displaced tibial eminence fractures: a biomechanical comparison[J]. Arthrosc J Arthrosc Relat Surg 21(10):1172–1176
Hunter RE, Willis JA (2004) Arthroscopic fixation of avulsion fractures of the tibial eminence: technique and outcome[J]. Arthrosc J Arthrosc Relat Surg 20(2):113–121
Hirschmann MT, Mayer RR, Kentsch A et al (2009) Physeal sparing arthroscopic fixation of displaced tibial eminence fractures: a new surgical technique[J]. Knee Surg Sports Traumatol Arthrosc 17(7):741–747
Fabricant PD, Osbahr DC, Green DW (2011) Management of a rare complication after screw fixation of a pediatric tibial spine avulsion fracture: a case report with follow-up to skeletal maturity[J]. J Orthop Trauma 25(12):e115–e119
Bale RS, Banks AJ (1995) Arthroscopically guided Kirschner wire fixation for fractures of the intercondylar eminence of the tibia[J]. J R Coll Surg Edinb 40(4):260–262
Boutsiadis A, Karataglis D, Agathangelidis F et al (2014) Arthroscopic 4-point suture fixation of anterior cruciate ligament tibial avulsion fractures[J]. Arthrosc Tech 3(6):e683–e687
Verdano MA, Pellegrini A, Lunini E et al (2014) Arthroscopic absorbable suture fixation for tibial spine fractures[J]. Arthrosc Tech 3(1):e45–e48
Lu XW, Hu XP, Jin C et al (2010) Reduction and fixation of the avulsion fracture of the tibial eminence using mini-open technique[J]. Knee Surg Sports Traumatol Arthrosc 18(11):1476–1480
In Y, Kim JM, Woo YK et al (2008) Arthroscopic fixation of anterior cruciate ligament tibial avulsion fractures using bioabsorbable suture anchors[J]. Knee Surg Sports Traumatol Arthrosc 16(3):286–289
Vega JR, Irribarra LA, Baar AK et al (2008) Arthroscopic fixation of displaced tibial eminence fractures: a new growth plate–sparing method[J]. Arthrosc J Arthrosc Relat Surg 24(11):1239–1243
Ying Z, Lin T, Yan S (2014) Arthroscopic single-row versus double-row technique for repairing rotator cuff tears: a systematic review and meta-analysis[J]. Orthopaed Surg 6(4):300–312
Kiliçoğlu Ö, Türker M, Yildız F et al (2014) Suture anchor tenodesis in repair of distal Achilles tendon injuries[J]. Eur J Orthop Surg Traumatol 24(1):117–122
Harris JD, Abrams GD, Yanke AB et al (2014) Suture anchor repair of quadriceps tendon rupture[J]. Orthopedics 37(3):183–186
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Funding
There is no funding source.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Rights and permissions
About this article
Cite this article
Xu, X., Liu, Z., Wen, H. et al. Arthroscopic fixation of pediatric tibial eminence fractures using suture anchors: a mid-term follow-up. Arch Orthop Trauma Surg 137, 1409–1416 (2017). https://doi.org/10.1007/s00402-017-2770-3
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-017-2770-3