Abstract
Ocular microtremor (OMT) is the smallest of three involuntary fixational micro eye movements, which has led to it being under researched in comparison. The link between OMT and brain function generates a strong rationale for further study as there is potential for its use as a biomarker in populations with neurological injury and disease. This structured review focused on populations previously studied, instrumentation used for measurement, commonly reported OMT outcomes, and recommendations concerning protocol design and future studies. Current methods of quantifying OMT will be reviewed to analyze their efficacy and efficiency and guide potential development and understanding of novel techniques. Electronic databases were systematically searched and compared with predetermined inclusion criteria. 216 articles were identified in the search and screened by two reviewers. 16 articles were included for review. Findings showed that piezoelectric probe is the most common method of measuring OMT, with fewer studies involving non-invasive approaches, such as contact lenses and laser imaging. OMT frequency was seen to be reduced during general anesthesia at loss of consciousness and in neurologically impaired participants when compared to healthy adults. We identified the need for a non-invasive technique for measuring OMT and highlight its potential in clinical applications as an objective biomarker for neurological assessments. We highlight the need for further research on the clinical validation of OMT to establish its potential to identify or predict a meaningful clinical or functional state, specifically, regarding accuracy, precision, and reliability of OMT.
Similar content being viewed by others
Introduction
Eye-tracking can provide insights into underlying cognitive mechanisms, such as attentional processing (Moran et al. 2018). Eye-tracking is utilized in various fields, such as medicine (Anderson and MacAskill 2013; Molitor et al. 2015), psychology (Hannula et al. 2010), sports (Discombe and Cotterill 2015; Kredel et al. 2017), and consumer behavior (Al-Azawai 2019; Bialkova et al. 2020). Examination of eye movements can provide an objective measure within neurological assessment, as specific eye movements can be attributed to specific brain regions and their functions (Stuart et al. 2019a; Hikosaka et al. 2000). Eye movements have been primarily categorized as saccades (rapid, jerk-like movements from one point of fixation to the next (Wade et al. 2003)), and fixations (time spent with eyes fixed on a visual target). Decline in ocular motor function has been linked to both neurological injury and disease, highlighting the potential in understanding, diagnosis, treatment, and prognosis of such impairments (Anderson and MacAskill 2013; Molitor et al. 2015; Mucha et al. 2014). Measurement of eye movements in neurological injury and disease is currently subjective, depending on clinical opinion providing potential for misdiagnosis (Baumann 2012; Tolosa et al. 2006). However, with advances in technology, objective measurement alternatives are becoming more readily available.
Ocular microtremor (OMT) may provide an objective measure for clinical use. First described in 1934, OMT is one of three involuntary eye movements that are present even when the eye appears still (Adler and Fliegelman 1934). OMT is considered a fixational movement and is a constant small amplitude, high-frequency tremor of both eyes (Robertson and Timmons 2007). OMT has been linked to the constant activity of the extra-ocular muscles stimulated by impulses from oculomotor neurons found in the brainstem (Robertson and Timmons 2007; Sheahan et al. 1993; Bolger et al. 1999; Shakhnovich 2012; Bojanic et al. 2001). Changes seen in OMT frequency occur because oculomotor neurons are embedded within the reticular formation of the brainstem (Robertson and Timmons 2007). The frequency of OMT ranges from 70 to 130 Hz in healthy individuals (Bolger et al. 1999a). Significantly lower OMT frequency has been recorded in patients under anesthesia (Bojanic et al. 2001) and a lack of OMT frequency has been recorded in individuals diagnosed with brainstem death (Bolger et al. 1999). Thus, OMT may provide a clinical tool for assessing brain stem function (Bolger et al. 1999a, 1999b; Coakley and Thomas 1977). Previous work has illustrated that OMT frequency changes with age, with significantly lower OMT frequency in those over the age of 60 (Bolger et al. 2001). Neurological diseases, such as Parkinson’s disease (PD) and multiple sclerosis (MS), have also shown decreased OMT frequency when compared to healthy controls (Bolger et al. 1999, 2000).
There is no gold standard technique for OMT measurement and methods range from invasive (e.g., piezoelectric techniques) to modern non-invasive technological assessment with eye-tracking devices (McCamy et al. 2013; Bengi and Thomas 1968; Kenny et al. 2013, 2014; Torre et al. 2016). Due to the lack of gold standard, the application of these OMT measurement protocols varies, which limits generalizability and interpretation of underlying deficits. Investigators who wish to measure and study OMT are left with a choice of measurement techniques and protocols that differ in many respects. In the process of developing robust and feasible protocols for clinical research, it is helpful to have evidence-based guidance. We therefore aimed to systematically review and summarize the current literature on OMT measurement and outcomes to aid the progression of future research.
We focused this review on the following: (1) the populations previously studied with OMT; (2) instrumentation used to measure OMT; (3) commonly reported OMT outcomes; and (4) recommendations concerning protocol design and future studies.
Methods
Search protocol
Four electronic databases were searched: PubMed, SCOPUS, Science Direct, and Web of Science. The key search terms in this review were “ocular microtremor” and “ocular micro tremor”. The search was limited to papers published between 1990 and April 2023 full journal articles only and articles written in English language to eliminate the potential for translational errors creating confusion due to complex language used. Studies were considered relevant if they incorporated terminology which contained the search term “ocular microtremor” in the title, abstract, or keywords. Findings were then screened, and any duplicates were removed. The remaining articles were then reviewed with consideration of the predetermined inclusion and exclusion criteria. These studies were then included in the review shown in Table 1.
Inclusion and exclusion criteria
Table 2 provides inclusion and exclusion criteria for papers, alongside the rationale for each criterion. Papers were only included if they demonstrated an objective measurement of OMT.
Data extraction and synthesis
Studies that met the inclusion and exclusion criteria were reviewed, and data pertaining to OMT were scrutinized by the reviewer (LG). Article titles and abstracts were also reviewed by a second reviewer (JD), and any discrepancies were resolved by an additional reviewer (RM). Data were extracted and synthesized into table format which were again confirmed by the second reviewer (JD). Key information was extracted from the articles, including demographics, sample size, control samples, and methods used. Study inclusion and exclusion criteria were also analyzed.
Results
Ocular microtremor data extraction
Figure 1 provides a flow chart with information regarding the different phases of the search process. A total of 216 articles were obtained from the search, 68 duplicate articles were identified, and then removed leaving 148 to be screened via literature review software. A further 28 duplicates were removed, leaving 120 to be screened. Of the remaining articles, 35 were inaccessible. Where a paper could not be accessed, attempts were made to source the paper or contact the authors, but where no response was given, the paper was excluded from the review. Titles and abstracts of the remaining 92 articles were screened against the predetermined inclusion and exclusion criteria in the review software. Additional 25 were removed as OMT was not the outcome measure, four were removed for not using human participants, and seven were removed as they were nonsense citations. A further three were removed for being comments, and two contents removed. This left 16 articles which remained and underwent full-text screening. Articles included in the review are presented in Table 2.
Sample populations
The reviewed articles (n = 16) investigated healthy individuals (n = 8) (Bolger et al.1999a, 1999b, 1992, Kenny et al. 2014; Sheahan et al. 1994; Spauschus et al. 1999; McCamy et al. 2013; Ryle et al. 2015), (Bolger et al. 1999), individuals scheduled for surgery under general anesthesia (propofol/sevoflurane) (n = 3) (Bojanic et al. 2001; Kevin et al. 2002; Heaney et al. 2004), individuals with multiple sclerosis (n = 2) (Brown 1998; Bolger et al. 2000), individuals with Parkinson’s Disease (n = 1) (Bolger et al. 1999), suspected brain stem death (n = 1) (Bolger et al. 1999), and oculomotor nerve palsy (n = 1) (Bolger et al. 1999). Table 2 presents full details of all studies in chronological order. The sample size in the studies ranged from n = 5 to n = 214 participants (average n = 40). The participants included in the reviewed studies were male dominant, (174 males out of 262 participants were reported–4 studies did not specify) with participants ranging from 17 to 88 years old.
Inclusion and exclusion criteria
Inclusion and exclusion criteria were not specified in several of the studies (n = 10). When they were included, history of neurological trauma or ocular disease was frequently identified as a source for exclusion (n = 6), as was presence of medication which might affect brain stem function (n = 2). Age was also identified as a limiting criteria (n = 4) with two restricting the research to 18 + years old (Kevin et al. 2002; Heaney et al. 2004) and two studies to 21 + years (Bolger et al. 1999, 2001) due to concern regarding informed consent. Pertaining to concern with informed consent, a cognitive score on the mini-mental state examination (MMSE) of 28 + was required in one study (Bolger et al. 1999).
Instruments and Procedures
Studies used a variety of techniques to measure OMT (see Table 2). Piezoelectric-based techniques were mostly used across the literature (n = 12) (Bolger et al.1992;1999; 1999a;1999b;2000; Sheahan et al. 1994; Bojanic et al. 2001; McCamy et al. 2013), two of which involved closed eye recordings (Kevin et al. 2002; Heaney et al. 2004). Other methods, such as contact lens-mounted accelerometers (n = 1) (Spauschus et al. 1999), non-contact far field method (n = 1) (Ryle et al. 2015), eyelid mounted accelerometers (n = 1) (Brown 1998), and laser speckle metrology (n = 1) (Kenny et al. 2014), were also utilized.
Table 2 shows equipment utilized to measure OMT in the literature. Most investigators administered local anesthetic for the scleral surface (n = 11). These were all piezoelectric studies apart from one which used contact lens-mounted accelerometers (Spauschus et al. 1999). To hold eyelids open, surgical tape was frequently used (n = 10). Eye retractors were also reported (n = 1). In some studies, head movement was anticipated as a source of noise and so to eliminate this, a headrest or a bite bar was used (n = 5). Recordings were taken over various time periods with some studies taking serial readings and some taking continuous recordings for up to 1 min. Where reported, OMT measurement was collected monocularly. If both eyes were tested, this was done independently.
Outcome measure: OMT characteristics
In all studies, the only reported outcome measure was OMT frequency. In healthy participants, the reported frequency ranged from 78.27 Hz (± 3.9 Hz) (Kenny et al. 2014) to 89.6 Hz (± 6 Hz) (Bolger et al. 1999b). OMT frequency was also observed in conscious and unconscious populations with the use of anesthesia. In the conscious, awake states, OMT frequency was reported as 80.6 Hz (SD = 5.9 Hz) (Bojanic et al. 2001) and 85 Hz (Kevin et al. 2002). This significantly reduced at the point of loss of consciousness to 43.8 Hz (SD = 7.3) (Bojanic et al. 2001) and 48 Hz (Kevin et al. 2002). Reviewed studies that looked at neurologically impaired populations reported OMT frequency was significantly reduced when compared to healthy individuals. In MS, OMT frequency was reported to be 71.3 Hz (SD = 10.5 Hz) and in those with MS and brain stem or cerebellar disease, 67.1 Hz (SD = 8.9 Hz) (Bolger et al. 2000). In PD, OMT frequency was 67.68 Hz (SD = 10.75) and in one participant, OMT was measured ON and OFF medication. There was a considerable difference between ON and OFF states with OMT frequency with ON being 73.8 Hz (SD = 5.6 Hz) which dropped to 58.9 Hz (SD = 10.6 Hz) when OFF (Bolger et al. 1999). It was also reported that there is no difference between OMT frequencies for each eye. However, frequency varied when measured on different days (Sheahan et al. 1994). In a sample of individuals with ocular nerve palsy, the normal, unaffected eye possessed an OMT frequency of 84.4 Hz (SD = 16.9), whereas the affected eye possessed a significantly lower frequency of 59 Hz (SD = 8.6) (Bolger et al. 1999). In another study, a significant negative correlation exists between OMT frequency and age (Bolger et al. 2001).
Discussion
To the authors’ knowledge, this review presents the first systematic synthesis of the literature examining OMT. A total of 16 studies met the inclusion criteria and were examined based on their methods, participants, and findings. We focused this review on the following: (1) the populations previously studied with OMT; (2) instrumentation used to measure OMT; (3) commonly reported OMT outcomes; and (4) recommendations concerning protocol design and future studies. Current methods of quantifying OMT were reviewed to analyze the efficiency and reliability of OMT as a measure. This review found that OMT frequency differs between different populations and possesses major clinical potential. However, the current methodologies are highly invasive and limit the clinical applicability of OMT measurement.
Sample populations
Sample size hugely varied across the reviewed studies (i.e., n = 8–214). Reviewed studies with larger samples involved healthy participants, those under general anesthesia or brainstem death. Smaller sample sizes were seen for neurological cohorts, such as PD and MS, which will impact reported data and reduce results generalizability. PD and MS are heterogeneous conditions and therefore larger sample sizes are required to reflect the populations adequately. For example, some participants experienced blepharospasm (a painful spasm of the eyelids) when the eyes were held open with tape or instruments (Sheahan et al. 1994). No visual function or ability features were used for inclusion or exclusion criteria, and many studies did not commonly collect demographic data or information regarding habits/activities (e.g., hours of sleep, screen time, etc.). These may account for intra-subject variability and would be interesting to investigate in future work. Other eye-tracking studies typically require visual function to be normal or near normal to ensure accurate performance that is not impacted by visual function impairment (Stuart et al. 2019). While OMT should be present in all individuals, regardless of visual function, it may influence ability to follow instructions that involve visual function (i.e., look ahead at visual target). Generally, outcomes from small cohorts may not accurately reflect or represent that of the general population of interest and furthermore create a lack of statistical power that could lead to inconsistency in findings. Therefore, more work is required in PD, MS, and other clinical populations to study the efficacy of this outcome.
Instruments and procedures
There was no consistent method of OMT measurement, but most reviewed studies used the piezoelectric method. This, however, possesses low clinical accessibility. First described by Bengi and Thomas in 1968 (Bengi and Thomas 1968), the piezoelectric technique for measuring OMT involves lowering a rubber probe onto the scleral surface while the eye is held open with an eyelid retractor or surgical tape (Bolger et al. 1999, 1999b). The piezoelectric element acts as a transducer and measures scleral displacement (Sheahan et al. 1994). While it is an accurate measure, it is outdated, and the invasive limitations outweigh the benefits, i.e., the need for the eye to be anesthetized (Bolger et al. 1999, 1992, 2000, 1999; Sheahan et al. 1994; Spauschus et al. 1999; Bojanic et al. 2001), inter-observer variability, requirement of a highly trained operator, and the fact that recording time is limited to reduce discomfort and eye dryness (Sheahan et al. 1994). Overall, this method is limited as an objective biomarker in clinical populations. Another potentially limiting factor of the piezoelectric method is the fact that it relies on constant uninterrupted contact with the sclera and there is an unknown loading effect of the probe. More recently, Ryle et al. (Ryle et al. 2015) demonstrated that a non-contact method was able to record OMT without causing a mechanical loading effect. This non-contact far field method described (Ryle et al. 2015) utilizes spatially incoherent illumination from a light-emitting diode (LED) and an ultra-fast, high-resolution black and white camera to capture eye movements. This method allows both horizontal and vertical fixational motions to be captured simultaneously without coming into contact with the eye itself. The relative frame-to-frame displacement could be calculated without having to tape eyelids open or probe the eyes surface. It is obvious that the piezoelectric method is outdated and is not clinically viable, thus limiting OMT as a potential clinical biomarker for neurological function or impairment.
A less-invasive technique described in the reviewed articles was the use of accelerometers, both contact lens-mounted accelerometers (Spauschus et al. 1999) and eyelid mounted accelerometers (Brown 1998). These techniques enabled changes in eye acceleration to be recorded during eye movements. The accelerometers weighed 0.5 g each and therefore are much more tolerable than the piezoelectric probe and having eyes held open. The accelerometer technique has a response range of up to 500 Hz—well above the expected range for OMT—and the response to acceleration in a plane other than the target direction is less than 3% suggesting that there is little noise interference (Brown and Day 1997). An additional accelerometer was also placed on the forehead to eliminate noise from head movements. This method allowed simultaneous recordings of both eyes. However, results in the reviewed articles showed little to no discrepancies between the two eyes in healthy subjects (Sheahan et al. 1994). Ratliff & Riggs (Ratliff and Riggs 1950) suggest that the reason this method did not gain widespread clinical acceptance is that they may not adhere to the eye adequately. However, this research was carried out in 1950 and as a result is likely outdated.
To ensure OMT provides an objective and clinically accessible biomarker, a non-invasive technique is required. In addition to the method used by Ryle et al. (2015), Kenny et al. (2014) also demonstrated that OMT could also be accurately measured non-invasively using laser speckle metrology (Kenny et al. 2014). Laser speckle metrology is the most recent method presented, and uses laser technology to create a speckle pattern of light and dark spots caused by interference (Kenny et al. 2013). This method offers a high-resolution non-invasive, compact, and portable technique for obtaining OMT data. It has been proven to be feasible and overcomes many of the current limitations associated with other more-invasive techniques (Al-Kalbani et al. 2009). This solution shows promise for non-invasive measurement of OMT; however, there is a need for more evidence using non-invasive devices for objective OMT measurement to provide clear understanding and allow accurate interpretation for clinical use.
Outcome measure: OMT characteristics and implications
This review has found that OMT frequency differs between healthy individuals and clinical groups, specifically those under anesthesia, brain stem death, and those with neurological impairments (PD, MS). Overall, regardless of group the OMT frequencies range between 70 and 150 Hz, in line with previous reports (Bolger et al. 1999). OMT frequency was reduced compared to healthy controls in those under anesthesia and was not present in brain stem death. Similarly, OMT frequency was found to be able to differentiate neurological populations from healthy controls, which is similar to wider eye-tracking literature. Eye movements are controlled by the extraocular muscles, which interconnect via a tract in the brainstem (Bae et al. 2013). Basal ganglia (BG) and cerebellum modulate the neural system for saccade generation, duration, and amplitude. Considering such a substantial area of the brain is involved in eye movements, it is no surprise that abnormalities in eye movements are useful for understanding brain activity and neurological disorders (Lal and Truong 2019). This is highlighted by Bolger et al. (1999) (Bolger et al. 1999) whose work in ocular palsy supports the notion that OMT has a neurogenic origin. The drop in OMT frequency also seen with anesthesia at loss of consciousness is particularly interesting in highlighting the link between OMT and neural activity as it is essential for patients to be unconscious during surgery, so a reduction in brain activity corroborates this. Moreover, eye-tracking is invaluable in enabling clinicians to discern brain dysfunction from patterns of abnormality and attributes this to different neurological states or neurological disorders (Terao et al. 2017). This knowledge signifies the importance of research on OMT and its possibilities. Specifically, OMT is a constant, involuntary eye movement, so its characteristics could provide insights into neurological functions without the need for extensive eye-tracking or cognitive tests that require relatively intact ability to follow instructions (which is lost with neurodegeneration or neurological impairment). Based on the findings in this review, Table 3 highlights recommendations for future research into OMT.
Conclusion
This is the first review of OMT measurement that has shown that protocols vary between studies and that very few studies have examined clinical cohorts. OMT is a quantifiable involuntary eye tremor that can be measured with various technologies, with more recent devices being non-invasive. OMT is generally reduced in those under anesthesia, or with neurological conditions, and is absent in those with brain stem death. Further quantification of OMT is needed to determine the effect of specific clinical conditions on its frequency, and aid in the development of further OMT outcome measures. Moreover, further research on the clinical validation of OMT is required to establish its potential to acceptably identify or predict a meaningful clinical or functional state, specifically regarding accuracy, precision, reliability, and validity of OMT.
Data availability
This is a review article of already available, published data. The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
Adler FH, Fliegelman M (1934) Influence of fixation on the visual acuity. Arch Ophthalmol 12(4):475–483
Al-Azawai M (2019) The application of eye-tracking in consumer behaviour. Int J Eng Technol. 8(12):83–86
Al-Kalbani M, Mihaylova E, Collins N, Toal V, Coakley D, Boyle G (2009) Ocular microtremor laser speckle metrology, vol 7176. SPIE, SPIE BiOS
Anderson TJ, MacAskill MR (2013) Eye movements in patients with neurodegenerative disorders. Nat Rev Neurol 9(2):74–85. https://doi.org/10.1038/nrneurol.2012.273
Bae YJ, Kim JH, Choi BS, Jung C, Kim E (2013) Brainstem pathways for horizontal eye movement: pathologic correlation with MR imaging. Radiographics 33(1):47–59. https://doi.org/10.1148/rg.331125033
Baumann CR (2012) Epidemiology, diagnosis and differential diagnosis in Parkinson’s disease tremor. Park Rel Dis. 18:S90–S92. https://doi.org/10.1016/S1353-8020(11)70029-3
Bengi H, Thomas JG (1968) Three electronic methods for recording ocular tremor. Med Bio Eng. 6(2):171–179. https://doi.org/10.1007/BF02474271
Bialkova S, Grunert KG, van Trijp H (2020) From desktop to supermarket shelf: Eye-tracking exploration on consumer attention and choice. Food Qual Pref 81:103839. https://doi.org/10.1016/j.foodqual.2019.103839
Bojanic S, Simpson T, Bolger C (2001) Ocular microtremor: a tool for measuring depth of anaesthesia? Br J Anaesth 86(4):519–522. https://doi.org/10.1093/bja/86.4.519
Bojanic S, Simpson T, Bolger C (2001) Ocular microtremor: a tool for measuring depth of anaesthesia? Article Brit J Anaesth 86(4):519–522. https://doi.org/10.1093/bja/86.4.519
Bolger C, Sheahan N, Coakley D, Malone J (1992) High frequency eye tremor: reliability of measurement. Clin Phys Physiol Meas 13(2):151–159. https://doi.org/10.1088/0143-0815/13/2/007
Bolger C, Bojanic S, Sheahan NF, Coakley D, Malone JF (1999a) Ocular microtremor in oculomotor palsy. J Neuroophthalmol 19(1):42–45
Bolger C, Bojanic S, Sheahan NF, Coakley D, Malone JF (1999b) Dominant frequency content of ocular microtremor from normal subjects. Vision Res 39(11):1911–1915. https://doi.org/10.1016/s0042-6989(98)00322-8
Bolger C, Phillips J, Bojanic S, Sheahan N, Coakley D, James M (1999c) Ocular microtremor in brain stem death. Neurosurgery 44(6):1201–1206. https://doi.org/10.1097/00006123-199906000-00024
Bolger C, Bojanic S, Sheahan NF, Coakley D, Malone JF (1999d) Ocular microtremor in patients with idiopathic Parkinson’s disease. J Neurol Neurosurg Psychiatry 66(4):528–531. https://doi.org/10.1136/jnnp.66.4.528
Bolger C, Bojanic S, Sheahan NF, Coakley D, Malone JF (1999e) Ocular microtremor in patients with idiopathic Parkinson’s disease. Art. J Neurol Neurosurg Psychiat. 66(4):528–531. https://doi.org/10.1136/jnnp.66.4.528
Bolger C, Bojanic S, Sheahan NF, Coakley D, Malone JF (1999f) Dominant frequency content of ocular microtremor from normal subjects. Article Vision Res 39(11):1911–1915. https://doi.org/10.1016/S0042-6989(98)00322-8
Bolger C, Bojanic S, Phillips J, Sheahan N, Coakley D, Malone J (1999g) Ocular microtremor in brain stem death. Article Neurosurg 44(6):1201–1206. https://doi.org/10.1097/00006123-199906000-00024
Bolger C, Bojanic S, Sheahan N, Malone J, Hutchinson M, Coakley D (2000) Ocular microtremor (OMT): a new neurophysiological approach to multiple sclerosis. J Neurol Neurosurg Psychiatry 68(5):639–642. https://doi.org/10.1136/jnnp.68.5.639
Bolger C, Bojanic S, Sheahan NF, Coakley D, Malone JF (2001) Effect of age on ocular microtremor activity. J Gerontol: Series A 56(6):M386–M390. https://doi.org/10.1093/gerona/56.6.M386
Brown P (1998) A new clinical technique for demonstrating changes in eye acceleration during horizontal saccades in patients with partial internuclear ophthalmoplegias. J Neuroophthalmol 18(1):36–39
Brown P, Day BL (1997) Eye acceleration during large horizontal saccades in man. Exper Brain Res. 113(1):153. https://doi.org/10.1007/BF02454151
Coakley D, Thomas JG (1977) The ocular microtremor record and the prognosis of the unconscious patient. Lancet 1(8010):512–515. https://doi.org/10.1016/s0140-6736(77)91374-5
De la Torre IM, Hernández Montes MDS, Flores-Moreno JM, Santoyo FM (2016) Laser speckle based digital optical methods in structural mechanics: a review. Opt Las Eng. 87:32–58. https://doi.org/10.1016/j.optlaseng.2016.02.008
Discombe RM, Cotterill ST (2015) Eye tracking in sport: A guide for new and aspiring researchers. Sport Exer Psychol Rev 11(2):49–58
Hannula DE, Althoff RR, Warren DE, Riggs L, Cohen NJ, Ryan JD (2010) Worth a glance: using eye movements to investigate the cognitive neuroscience of memory. Front Hum Neurosci 4:166–166. https://doi.org/10.3389/fnhum.2010.00166
Heaney M, Kevin LG, Manara AR et al (2004) Ocular microtremor during general anesthesia: results of a multicenter trial using automated signal analysis. Anesth Analg 99(3):775–780. https://doi.org/10.1213/01.Ane.0000133145.98702.C0
Hikosaka O, Takikawa Y, Kawagoe R (2000) Role of the Basal Ganglia in the Control of Purposive Saccadic Eye Movements. Physiol Rev 80(3):953–978. https://doi.org/10.1152/physrev.2000.80.3.953
Kenny E, Coakley D, Boyle G (2013) Ocular microtremor measurement using laser-speckle metrology. J Biomed Opt 18(1):16010. https://doi.org/10.1117/1.Jbo.18.1.016010
Kenny E, Coakley D, Boyle G (2013) Biospeckle in the human sclera and impact on laser speckle correlation measurement of eye tremor. J Biomed Opt. https://doi.org/10.1117/1.JBO.18.9.097009
Kenny E, Coakley D, Boyle G (2014) Non-contact in vivo measurement of ocular microtremor using laser speckle correlation metrology. Physiol Meas 35(7):1229–1243. https://doi.org/10.1088/0967-3334/35/7/1229
Kevin LG, Cunningham AJ, Bolger C (2002) Comparison of ocular microtremor and bispectral index during sevoflurane anaesthesia. Br J Anaesth 89(4):551–555. https://doi.org/10.1093/bja/aef225
Kredel R, Vater C, Klostermann A, Hossner E-J (2017) Eye-tracking technology and the dynamics of natural gaze behavior in sports: A systematic review of 40 years of research. Front Psychol 8:1845
Lal V, Truong D (2019) Eye movement abnormalities in movement disorders. Clin Parkin Rel Disord. 1:54–63. https://doi.org/10.1016/j.prdoa.2019.08.004
McCamy MB, Collins N, Otero-Millan J et al (2013) Simultaneous recordings of ocular microtremor and microsaccades with a piezoelectric sensor and a video-oculography system. PEER J. 1:14
Molitor RJ, Ko PC, Ally BA (2015) Eye movements in Alzheimer’s disease. J Alzheimers Dis 44(1):1–12
Moran A, Campbell M, Ranieri D (2018) Implications of eye tracking technology for applied sport psychology. J Sport Psychol Act. 9(4):249–259. https://doi.org/10.1080/21520704.2018.1511660
Mucha A, Collins MW, Elbin R et al (2014) A brief vestibular/ocular motor screening (VOMS) assessment to evaluate concussions: preliminary findings. Am J Sports Med 42(10):2479–2486
Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD et al (2021) The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 372:n71. https://doi.org/10.1136/bmj.n71
Ratliff F, Riggs LA (1950) Involuntary motions of the eye during monocular fixation. J Exp Psychol 40(6):687–701. https://doi.org/10.1037/h0057754
Robertson J, Timmons S (2007) Non-invasive brainstem monitoring: The ocular microtremor. Art Neurol Res 29(7):709–711. https://doi.org/10.1179/016164107X240198
Ryle JP, Vohnsen B, Sheridan JT (2015) Simultaneous drift, microsaccades, and ocular microtremor measurement from a single noncontact far-field optical sensor. J Biomed Opt 20(2):27004. https://doi.org/10.1117/1.Jbo.20.2.027004
Shakhnovich A (2012) The brain and regulation of eye movement. Springer Science & Business Media.
Sheahan NF, Coakley D, Hegarty F, Bolger C, Malone J (1993) Ocular microtremor measurement system: Design and performance. Med Biol Eng Comp 31(3):205–212. https://doi.org/10.1007/BF02458038
Sheahan NF, Coakley D, Bolger C et al (1994) Sources of variance in ocular microtremor. Physiol Meas 15(1):101–106. https://doi.org/10.1088/0967-3334/15/1/009
Spauschus A, Marsden J, Halliday DM, Rosenberg JR, Brown P (1999) The origin of ocular microtremor in man. Exp Brain Res 126(4):556–562. https://doi.org/10.1007/s002210050764
Stuart S, Hickey A, Vitorio R et al (2019) Eye-tracker algorithms to detect saccades during static and dynamic tasks: a structured review. Physiol Meas 40(2):02. https://doi.org/10.1088/1361-6579/ab02ab
Stuart S, Lawson RA, Yarnall AJ et al (2019a) Pro-saccades predict cognitive decline in Parkinson’s disease: ICICLE-PD. Mov Disord 34(11):1690–1698
Terao Y, Fukuda H, Hikosaka O (2017) What do eye movements tell us about patients with neurological disorders? An introduction to saccade recording in the clinical setting. Proce Japan Acad, Series B 93(10):772–801. https://doi.org/10.2183/pjab.93.049
Tolosa E, Wenning G, Poewe W (2006) The diagnosis of Parkinson’s disease. Lanc Neurol 5(1):75–86. https://doi.org/10.1016/S1474-4422(05)70285-4
Wade NJ, Tatler BW, Heller D (2003) Dodge-ing the issue: Dodge, Javal, Hering, and the measurement of saccades in eye-movement research. Perception 32(7):793–804
Funding
This research was supported by a collaborative PhD studentship between Northumbria University and Head Diagnostics to Lisa Graham (PIs: Dr Morris and Dr Stuart). Additional funding was received via a research grant from Private Physiotherapy Educational Foundation (PPEF—#368; PI: Dr Stuart). Dr Stuart is funded in part by a Parkinson’s Foundation postdoctoral fellowship for basic scientists (PF-FBS-1898) and a Parkinson’s Foundation clinical research award (PF-CRA-2073).
Author information
Authors and Affiliations
Contributions
LG, RM, and SS conceived the project and review. Initial first draft write up of the manuscript was performed by LG, RM, and SS. LG, JD, and RM performed the strategic structured literature search. LG, JD, RV, AG, RM, and SS commented on previous versions of the manuscript, and all approved the final version.
Corresponding author
Ethics declarations
Conflict of interest
The authors report no conflicts of interest.
Ethical and consent
Not applicable.
Consent for publication
Not applicable.
Additional information
Communicated by Winston D. Byblow.
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Graham, L., Das, J., Vitorio, R. et al. Ocular microtremor: a structured review. Exp Brain Res 241, 2191–2203 (2023). https://doi.org/10.1007/s00221-023-06691-w
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00221-023-06691-w