Abstract
Pesticides such as organothiophosphates (OTPs) are neurotoxically active and enter the aquatic environment. Bioassays, using acetylcholinesterase (AChE), a suitable substrate and reactant, can be applied for the photometric detection of AChE-inhibiton (AChE-I) effects. The oxidized forms of OTPs, so-called oxons, have higher inhibition potentials for AChE. Therefore, a higher sensitivity is achieved for application of oxidized samples to the AChE assay. In this study, the oxidation of malathion, parathion, and chlorpyrifos by n-bromosuccinimide (NBS) was investigated in an approach combining high-performance thin-layer chromatography (HPTLC) with an AChE-I assay. Two AChE application approaches, immersion and spraying, were compared regarding sensitivity, precision, and general feasibility of the OTP effect detection. The oxidation by NBS led to an activation of the OTPs and a strong increase in sensitivity similar to the oxons tested. The sensitivity and precision of the two application techniques were similar, although the spray method was slightly more sensitive to the oxidized OTPs. The 10% inhibition concentrations (IC10) for the spray approach were 0.26, 0.75, and 0.35 ng/spot for activated malathion, parathion, and chlorpyrifos, respectively. AChE-I effect recoveries in samples from a stormwater retention basin and receiving stream were between 69 and 92% for malathion, parathion, and chlorpyrifos. The overall workflow, including sample enrichment by solid-phase extraction, HPTLC, oxidation of OTPs, and AChE-I assay, was demonstrated to be suitable for the detection of AChE-I effects in native water samples. An effect of unknown origin was found in a sample from a stormwater retention basin.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
The worldwide use of pesticides has caused a contamination of the environment in all compartments such as water bodies, soil, and air. Pesticides and biocides can harm and alter organisms, populations, and entire food webs in several ways. Some compounds are suspected of being carcinogenic or influencing hormone balance, so that residues in food and ground and drinking water can also pose a risk for humans [1]. Pesticides and biocides are introduced into the aquatic environment via runoff from agricultural areas, discharges from combined or separate sewer systems and wastewater treatment plants [2,3,4,5]. Biocides used in non-agricultural sectors can enter the environment, for example, when they evaporate or leach from facade painting [6, 7]. In addition, pesticide residues are found in food [8].
Organophosphates and carbamates are two widespread pesticide groups and have been analyzed in different matrices all the way from plants and soils to the aquatic system [9, 10]. These two groups of pesticides inhibit acetylcholinesterase (AChE), which occurs in the nervous system of mammals, birds, fish, reptiles, and insects [11,12,13]. Enzyme-based biosensors were used for neurotoxicity testing of pesticides in the environment [14]. The AChE activity can be measured by well-established AChE assays [15,16,17,18]. The combination of high-performance thin-layer chromatography (HPTLC) with AChE-I assays has been successfully demonstrated and used for effect-directed analysis (EDA) of environmental, food, and plant samples [19,20,21,22,23,24,25,26,27,28]. Organothiophosphates (OTPs), such as chlorpyrifos and malathion, become stronger AChE inhibitors when the sulfur atom in the phosphorus-sulfur bond is replaced biologically (metabolic or microbiological actions) or chemically (chemical or photo-oxidation) by an oxygen atom [11,12,13, 18, 19, 29]. The OTPs are not always completely oxidized to the respective oxons, but other products or a further transformation may take place [30, 31]. Higher inhibition sensitivities can be achieved by a pre-oxidation of OTPs whereby bromine is used by several authors before applying an AChE-I assay on HPTLC plates [19, 32, 33]. Other studies presented a biological activation of OTPs [34,35,36]. OTPs in lower inhibition concentrations are detectable and most important the metabolic OTP activation in organisms can be simulated in this way. N-Bromosuccinimide (NBS) is an alternative bromine containing oxidizing agent that is used in AChE-I assays and has proven to be suitable for a complete oxidation of OTPs in water samples [37, 38].
Two methods, immersion and spraying, for the application of biosensors on HPTLC plates have been used in a study by Azadniya and Morlock [39]. Mendoza et al. [20] and Stütz et al. [23] used, as in this study, indoxyl acetate as an esterase substrate but each of them employed a different method to apply the esterase solution on thin-layer plates: immersion or spraying. In a previous work, an immersion and a spray method for application of yeast suspension on HPTLC plates were compared whereas a similar sensitivity and a better precision of the spraying approach were observed [40]. Schoenborn et al. [41] sprayed yeast cells onto HPTLC plates and observed an unprecedented sensitivity of the planar yeast estrogen screen compared to immersion.
This study aims to demonstrate that oxidation of OTPs by NBS is successful not only in an AChE-I microtiter assay but also in a combination of HPTLC, oxidation, and AChE-I assay (HPTLC-Ox-AChE-I). An expected increase in sensitivity will be demonstrated by investigating dose–response relations of malathion, parathion, chlorpyrifos, and related oxons either with or without oxidation by NBS after chromatographic separation. Moreover, it is interesting to ask whether differences in sensitivity, precision, and general feasibility can be observed in an HPTLC-Ox-AChE-I approach when the enzyme is sprayed onto the HPTLC plates or the plates were immersed into the enzyme solution. As a proof of concept, native water samples from a stream and connected stormwater retention basin were investigated with the HPTLC-Ox-AChE-I method after enrichment by solid-phase extraction (SPE).
Material and methods
Chemicals
The pesticides parathion, chlorpyrifos, and malathion as well as the oxons paraoxon and malaoxon were purchased from Sigma-Aldrich GmbH (Steinheim, Germany). Chlorpyrifos-oxon was purchased from LGC standards GmbH (Wesel, Germany). All standards had a purity of > 95%. AChE from electric eel (Electrophorus electricus), acetylthiocholine (ATCL), NBS, 5,5′-dithiobis(2-nitrobenzoic acid) (DTNB), ascorbic acid, and bovine serum albumin (BSA) were purchased from Sigma-Aldrich GmbH (Steinheim, Germany). Tris(hydroxymethyl)aminomethane (TRIS) was purchased from Carl Roth GmbH + Co. KG (Karlsruhe, Germany). HCl was purchased from Merck (Darmstadt, Germany). Indoxyl acetate was purchased from Thermo Fisher Scientific (Geel, Belgium). Methanol (LC–MS grade), acetone (LC–MS grade), dichloromethane (LC–MS grade), and water (LC–MS grade) were all purchased from Th. Geyer GmbH & Co. KG (Renningen, Germany). Cyclohexane (LC–MS grade) was purchased from LGC Standards GmbH (Wesel, Germany).
AChE-inhibition microtiter assay
Stock solutions (1 mg/mL) of NBS and ascorbic acid were each freshly prepared before the test and then diluted to 10 µg/mL and 100 µg/mL, respectively. The assay was performed with modifications according to Ellman’s method [15]. OTPs, oxons, water, and methanol blanks (15 µL) were each mixed with 15 µL of NBS (10 µg/mL) in a 96-well plate. After an incubation at room temperature for 5 min, the reaction was stopped by adding 15 µL ascorbic acid (100 µg/mL). For the test setup without oxidation, OTPs, oxons, water, and methanol blanks (15 µL) were mixed with 30 µL water per well. Subsequently, 200 µL of a DTNB solution (0.15 mM), buffered in TRIS/HCl at a pH of 7.4, was added to each well of both test setups. Then, 20 µL of an AChE solution (0.5 U/mL), also buffered in TRIS/HCl at a pH of 7.4, was added. An incubation at 30 °C for 30 min without shaking followed. An ATCL solution (0.8 mM) was freshly prepared with water and 30 µL per well was added after incubation. During another incubation at room temperature for 30 min, ATCL was cleaved by AChE into thiocholine and acetic acid. Thiocholine reacts with DTNB to 2-nitro-5-thiobenzoate [15]. The absorbance of the yellow-colored anion was photometrically measured at 405 nm (Sunrise Remote, Tecan Group AG, Männedorf, Schweiz). A flow chart of the used procedure is shown in Fig. S1.
Dose–response relationship
Dilution series with eight concentrations of the three OTPs and related oxons (Tab. S1) were freshly prepared from stock solutions (1–10 mg/mL) in methanol. The OTPs and oxons were tested in duplicates with and without prior oxidation in two measurements as described in the “AChE-inhibition microtiter assay” section. Eight water and eight methanol blanks were tested per test setup (oxidation and no oxidation). Of these, two were tested without AChE and two without ATCL. The mean AChE activity (absorption at 405 nm, n = 4) was related to the specific inhibitor dose. The statistic program Prism (version 5.00, Graph Pad Software, San Diego, USA) was used to generate dose–response curves (4-PL fit) and to determine inhibition concentrations (ICs) for the three OTPs and related oxons. The 95% confidence intervals of the curves and the standard deviations of the mean AChE activity were also calculated. The lower boundary of the curves is fixed to 0 and the highest mean activity defines 100%.
Combination of HPTLC and AChE-inhibition assay
HPTLC
LiChrospher 10 × 20 cm HPTLC Silica gel 60 F254s plates (Merck, Darmstadt, Germany) with a layer thickness of 170–190 µm and spherical silica particles with a size of 7 µm were used. The HPTLC plates were immersed twice in 2-propanol for 20 min, each time followed by a drying step at room temperature for 20 min. The plates then were pre-developed with methanol, dried for 20 min at room temperature, heated at 105 °C for 20 min, and stored in a desiccator for further use. The automatic TLC Sampler 4 (ATS 4, CAMAG AG, Muttenz, Switzerland) was used for sample application. The desired sample volumes were sprayed as 6-mm-wide bands onto the HPTLC plates with an application speed of 300 nL/s. The distances of the exterior bands from the edges of the plates were 15 mm. The distance from the bottom edge was 8 mm for all bands. Methanol was used as rinsing solvent. The following further application parameters were used: filling speed 15 µL/s, pre-dosage volume 200 nL, retraction volume 200 nL, rinsing vacuum time 4 s, filling vacuum time 0 s, rinsing cycles 2, and filling cycles 1. The development of the HPTLC plates was realized by the Automated Multiple Development 2 (AMD 2, CAMAG, Muttenz, Switzerland). The OTPs, their oxons, and environmental samples were separated with an eluent mixture of cyclohexane, dichloromethane, and acetone in different proportions and with increasing migration distances (Fig. S2). After each development step, a drying step of 3 min under vacuum followed. The final migration distance was 80 mm and the whole procedure took approximately 45 min. In addition, a simpler development process was used containing only the last step of the previous described method.
Chemical oxidation of OTPs and AChE-inhibition assay
After chromatographic development, 10 mL of freshly prepared NBS (100 µg/mL) was sprayed onto the HPTLC plates with a glass reagent sprayer, followed by a 5-min incubation at room temperature. The following AChE-I assay was performed in parts according to Mendoza et al., Stütz et al., and Weins and Jork [20, 22, 42]. AChE was buffered in TRIS/HCl at a pH of 7.8 (2.5 U/mL). The AChE solution was either sprayed onto the HPTLC plates with a glass reagent sprayer until the plates were evenly moist (approx. 10 mL) or the plates were immersed in the AChE solution using the Chromatogram Immersion Device 3 (CID 3, CAMAG, Muttenz, Switzerland). The immersion volume, speed, time, and depth were approx. 200 mL, 2.5 cm/s, 2 s, and approx. 85 mm, respectively. Afterward, the plates were placed separately in closed plastic boxes, which contained paper towels moistened with water to gain a saturated atmosphere. An incubation at 37 °C for 5 min followed. The substrate indoxyl acetate was freshly prepared in methanol at a concentration of 20 mg/mL and 5 mL was sprayed onto the HPTLC plates with a glass reagent sprayer. During 45-min incubation time at room temperature, AChE cleaves the substrate into indoxyl and acetate. The indoxyl reacts with oxygen to the blue indigo dye. When AChE was inhibited, no indigo was produced and the spot stayed white. The TLC Scanner 3 (CAMAG, Muttenz, Switzerland) was used to scan each track on the plates at 670 nm using the fluorescence mode without optical filter. The CAMAG-embedded software Wincats (Vers. 1.4.9) was used to provide chromatograms of each track and to evaluate inhibition zones.
Separation of organothiophosphates and oxons by HPTLC
The mean retardation factors (RFs) and standard deviations (SDs) (n = 18) of the OTPs and oxons were calculated using Excel 2013 (vers. 15.0.5172.1000, Microsoft, Redmond, USA). For the four-step development process, the RFs and SDs from the different tested amounts of the dose–response investigations (see the “Dose–response relationship” section) were used (n = 18). The separation of OTPs and oxons with the single-step development was done in duplicate on two HPTLC plates (n = 4). The influence of the single- and four-step development on the migration of sample matrix was investigated by using a SPE extract from a combined sewer overflow.
Dose–response relationship
Several amounts of an OTP mix and an oxon mix were applied on HPTLC plates (Tab. S2) and tested as described in the “Combination of HPTLC and AChE-inhibition assay” section. Three plates were used for each dilution series. The application volume was 10 µL for investigating OTPs with following oxidation and 100 µL for testing OTPs without following oxidation. The application volume for the oxons was 10 µL. They were tested without oxidation step also in triplicates. The peak heights were used for evaluation. Only peaks that have a signal-to-noise ratio ≥ 3 were considered in the evaluation. The height next to the respective peak defines the noise. The first detected peak at one of the applied concentrations with a signal to noise ratio ≥ 3 defines the LOD for the specific substance and the respective application method. The mean AChE-I (mean peak height, AU at 670 nm, n = 3) was related to the inhibitor amounts. Prism was used to generate dose–response curves (4-PL fit) and to determine ICs for the three OTPs (oxidized and unoxidized) and related oxons. The 95% confidence intervals of the curves and the standard deviations of the mean peak heights were also calculated. The lower boundary of the curves is fixed to 0 and the highest mean peak height defines 100%.
Proof of concept using environmental samples
Sampling
Grab samples were taken in March and August 2020 from a stormwater retention basin, which is connected to a highway nearby, and up- and downstream the receiving stream Deininghauser Bach near Deininghausen, Germany. A field blank was prepared with LC–MS grade water, which was used to wash the sampling vessel and opened at the sampling points. The samples were cooled during transport and stored < 8 °C until further sample preparation.
Sample preparation
The samples were enriched by SPE within 24 h after sampling. Moreover, the field blank and water for a SPE blank were enriched in the same way. For additional matrix investigations, 1 mL malathion, parathion, and chlorpyrifos (100 ng/mL in methanol) were spiked into native samples taken in August 2020 and a water control before being loaded on the SPE cartridges. The cartridges (150 mg, Oasis HLB 6 cc, Waters GmbH, Eschborn, Germany) were conditioned with methanol (2 × 5 mL) and equilibrated with water (2 × 5 mL), before being loaded with 1000 ± 5 mL sample (the exact volume was determined by weighting) through a polytetrafluoroethylene tube. After drying the cartridges under vacuum, they were stored at − 18 °C until further usage. The cartridges were eluted with methanol (5 × 5 mL) that was evaporated afterward at 60 °C under a gentle nitrogen gas stream. The dried extracts were redissolved in 1 mL methanol to achieve a nominal 1000-fold enrichment.
HPTLC and AChE-inhibition assay
The extracts, spiked samples, positive controls (PC: mix of malathion, parathion, and chlorpyrifos), and blanks were tested with the HPTLC-Ox-AChE-I method as described in the “Combination of HPTLC and AChE-inhibition assay” section. Each sample was tested in duplicates on two HPTLC plates (n = 4). The application volume was 100 µL resulting in a PC of 2000 ng/spot. The resulting amounts for the matrix investigation were 1000 and 10 ng/spot for the PCs and 10 ng/spot for the spiked samples. The matrix investigation was performed with and without the oxidation step. Excel was used to relate the peak areas of the spiked samples to the peak areas of the PCs (10 ng/spot). Differences between both approaches (oxidation and no oxidation) were shown by comparing the results of the spiked samples and PCs.
Results and discussion
AChE-inhibition microtiter assay
In a preliminary experiment using microtiter plates, it was confirmed that oxidation with NBS is suitable to increase the AChE-I potential of the tested OTPs, and in this way, the sensitivity of AChE assays to OTPs as shown in other studies [36, 43]. Although concentrations up to 500 µg/mL were used, the inhibition intensities of the unoxidized OTPs were not high enough to generate full sigmoidal dose–response curves in contrast to oxidized OTPs (Fig. 1).
The observed differences of the ICs between oxons and oxidized OTPs could be due to an incomplete oxidation of OTPs to their corresponding oxons, a formation of other non-active products, or a decay of formed oxons. Kralj et al. [37] showed that with an increasing NBS concentration formed oxons could not be detected or the signals decreased, which could be an indication for a further transformation of the oxons. In a further study by Kralj et al. [31], it is shown that several transformation products were formed during photolysis or photocatalysis of malathion.
The increase in toxicity of OTPs due to biotransformation during natural metabolism can be mimicked in a simple way by using NBS for chemical oxidation. Biological activation of OTPs with cytochrome P450 proteins is maybe closer to the metabolism in vivo. However, in vivo metabolism depends on different cytochrome P450 types and differs between organisms and could be even sex-specific [44, 45]. Studies often used one enzyme for activation of OTPs such as a genetically engineered P450 or chloroperoxidase [35, 36, 46]. In comparison, the chemical oxidation process presented is much less demanding in terms of preparation, chemicals, and materials. In addition, biological activation requires a buffer with a pH value that is within the optimum of the enzyme used for oxidation which does not necessarily match a subsequent AChE-I microtiter assay. Thus, the used oxidation method is a simpler and more robust procedure for testing native water samples. The sensitivity of the following HPTLC-Ox-AChE-I approach was in a comparable range to the AChE-I microtiter assay. However, the application volume of the HPTLC-Ox-AChE-I approach is decisive, so that better sensitivities can also be achieved. The IC50 of malathion, parathion, and chlorpyrifos for the microtiter assay were 35, 41, and 12 µg/L, respectively (Tab. S3). In comparison, when 100-µL sample was applied onto the HPTLC plate, the IC50 of malathion, parathion, and chlorpyrifos were 14, 42, and 15 µg/L, respectively.
High-performance thin-layer chromatography
For the dose–response investigations and following analysis of environmental samples, a development method was needed that is able to separate malathion, parathion, chlorpyrifos, and the related oxons on the HPTLC plate. With the four-step development, it was possible to separate all three OTPs and the oxons to a sufficient extent for the following investigations (Table 1 and Fig. S4). The single-step method allowed a separation of all 6 compounds with reduced time, cost, and solvent consumption (Tab. S5). In addition, attempts were made to better separate polar matrix of environmental samples from non-polar fractions. For this purpose, an unconventional approach, the four-step HPTLC development procedure with increasing migration distance and increasing elution power (Fig. S2), was compared to the single-step development method. A sample extract from a combined sewer overflow (CSO) was separated by the four-step and the single-step development procedures. The four-step development showed less migration of visible sample components in comparison to the single-step method before applying the AChE-I assay (Fig. S5). Using the four-step development, the sample matrix had less influence on at least the last third of the solvent migration distance in contrast to the single-step development. Whether matrix retention on a HPTLC plate can actually be achieved with such a development and what benefit it has over single-step or multi-step development with increasing migration distance and decreasing elution power should be determined in further, more in-depth studies. However, the four-step development was used for the following dose–response experiments and analysis of water samples because a sufficient separation of the OTPs was achieved and an influence of the separation method on the results of dose–response investigations is rather unlikely.
Oxidation on high-performance thin-layer plates
The dose–response relations of malathion, parathion, chlorpyrifos, and the related oxons were used to evaluate the oxidation by NBS on the HPTLC plate. In Fig. 2, Tab. S4, and Tab. S6, it is obvious that the oxidation of the three OTPs on HPTLC plates can be applied as expected. The sensitivity of the HPTLC-AChE-I assay can be increased dramatically for the detection of OTPs by oxidation with NBS. Differences between the AChE-I potential and thus the ICs of the tested oxons and the activated OTPs (Fig. 2, Fig. S4, and Tab. S4) could be due to an insufficient oxidation of the OTPs on the HPTLC plate. Another possibility is, as discussed for the AChE-I microtiter assay, a formation of other OTP products or a partial decay of the formed oxons during the following incubation times. The final scan of the HPTLC plate takes place about an hour after the application of NBS. Akkad et al. [33] used bromine for oxidation before applying a HPTLC esterase inhibition assay (HPTLC-EI) and showed an increase of the inhibition potential of OTPs. They also observed differences of the esterase inhibition between the activated OTPs and corresponding oxons. Azadniya et al. [34] used an S9 mixture to metabolize OTPs successfully on HPTLC plates. After sample application, a pre-wetting step follows before they applied the S9 mixture. An incubation of 30 min followed. The benefit of the here presented oxidation method with NBS is its simplicity: one application step followed by an incubation of 5 min. For a further increase of the sensitivity, a higher amount of NBS for oxidation could be reasonable. However, a concentration of 1 mg/mL NBS was tested, resulting in a lower activity or inhibition of AChE. Less indoxyl acetate seemed to be cleaved by AChE, and therefore, less indigo was formed. The HPTLC plate only became a blue tinge instead of a stronger blue color.
Comparison between immersion and spray methods
The comparison between immersion and spray approaches revealed that when using the immersion method to apply AChE on the HPTLC plates, the OTPs showed significantly higher RFs than using the spray approach (D’Agostino and Pearson omnibus normality test and Mann–Whitney test) (Table 1). A reason could be that the immersion method influences the migration retrospectively. However, this assumption is counteracted by the fact that the RFs of the oxons do not differ significantly from each other. Notable differences in the effect peaks’ width were not observed between immersion and spray methods, which would have to be assumed if the immersion method had an influence. Since the immersion line (85 mm) is quite close to the solvent front (80 mm) and the OTPs again have very high RF values, a shift of the OTPs may have occurred in the upper part of the plate near the immersion line. After using a combination of HPTLC and enzyme inhibition assay in which plates were immersed in the enzyme solution, Akkad and Schwack [21] showed that some OTP spots with very high RF values were more blurred than compounds with RF values less than 0.5.
The comparison between immersion and spray approaches with the dose–response investigations showed that the spray method had a slightly better sensitivity to all tested activated OTPs (Fig. 2, Tab. S4, and Tab. S6). Low concentrations are thus more likely to be detected. The IC10s substantiate that. In another study, the application of yeast cells on the HPTLC plate for the detection of endocrine effects was compared [40]. An overall similar sensitivity was shown between spray and immersion approaches. Schoenborn et al. [41] observed a better sensitivity of the planar yeast estrogen screen by spraying yeast suspension onto HPTLC plates. One reason for a better sensitivity of spray methods is maybe that substances such as OTPs could be extracted to a small extent from the HPTLC plates during the immersion process. Schoenborn et al. [41] obtained higher peak quality with the spray method and blurred peaks with the immersion approach. A difference in the peak quality such as wider peaks with the immersion than with the spray method could not be observed in this study. The linear ranges between IC20 and IC80 are suitable for calibration. A comparison of the precision between the two application methods does not give a consistent picture. The 95% confidence intervals of the dose–response curves were narrower for the activated OTPs when using the immersion method, but wider for the oxons, in comparison to the spray method (Fig. 2, Tab. S4). In a previous study, investigating the application of a yeast suspension, the spray approach was slightly more precise than the immersion method [40]. Differences were the use of an airbrush to apply the yeast suspension onto the HPTLC plate until it was evenly moist. In this study, a glass reagent sprayer was used to spray the AChE solution onto the HPTLC plate until it was evenly wet, almost as with the immersion method, to guarantee an even distribution. Azadniya and Morlock compared immersion and piezoelectric spraying for application of cholinesterase and substrate solutions on HPTLC plates [39]. Besides many advantages of the spray method, they reported that the main argument in favor of the immersion method is its simplicity. This was also the case in this study because complete wetting of the HPTLC plates took much longer than it did with the immersion method. The spraying method was therefore less user-friendly, which could be counteracted by automatic spraying methods [39, 47]. Despite the slight differences in sensitivity, precision, and handling, both application methods behave very similar and can be used for the detection of AChE-I effects in an HPTLC-Ox-AChE-I approach. The spray approach was used for the following proof of concept with environmental samples because of the slightly higher sensitivity and the associated higher probability of detecting effects in low concentration ranges.
Environmental samples
Samples taken from a stream and a connected stormwater retention basin (see the “Sampling” section) were analyzed using the developed HPTLC-Ox-AChE-I method including an enrichment by SPE. Besides the investigation of unknown AChE inhibition effects, the samples taken in August 2020 were spiked with malathion, parathion, and chlorpyrifos to show the recovery of the effects triggered by the OTPs. No notable differences between the stream and stormwater basin matrix were observed (Table 2). Malathion showed the highest recovery of the effect peak area related to the tested positive control. The recoveries in comparison to the positive control were between 81 and 92% for Malathion after SPE and HPTLC-Ox-AChE-I. The recoveries of parathion and chlorpyrifos were between 75–82% and 69–78%, respectively. A study by Akkad and Schwack, who combined HPTLC with a multi-enzyme inhibition assay with prior oxidation of organophosphates, showed recoveries of 91–106% for parathion, chlorpyrifos, and paraoxon in apple juice and tap water samples [33]. No notable matrix effects of the native samples could be shown in comparison to an ultrapure water sample spiked with the OTPs (Table 2). A reason for partly lower recoveries in the ultrapure water sample could be the organic material in the native samples that was retained in the cartridge and to which additional molecules bound. The spiked samples were also tested without oxidation. Neither the spiked water samples nor the positive control (10 ng/spot) showed any effect peaks. Thus, the oxidation by NBS works with native surface water sample extracts on HPTLC plates. If the samples were oxidized, the PC concentration (1000 ng/spot) is in the maximum inhibition plateau (Fig. 2). At this level, the peak heights do not increase but the areas continue to increase. Therefore, the peak area was used for evaluation. Only the positive control with 1000 ng/spot showed peaks for all three OTPs, but with lower intensities than the same positive control tested with oxidation step. The peak areas differed by a factor of 5–8 (Fig. S3). This shows that the chemical oxidation by NBS on HPTLC plates is a robust way to mimic the natural activation of OTPs by biotransformation.
The results showed that the overall workflow with prior sample enrichment by SPE is suitable to detect AChE-I effects caused by OTPs in surface water samples. This was confirmed by an AChE-I effect detected in an unspiked stormwater basin sample taken in March 2020 caused by unknown substances (Fig. 3). The samples taken in August 2020 showed no AChE-I effects. The presented HPTLC-Ox-AChE-I approach should facilitate subsequent analysis, because the complexity of the sample is reduced by HPTLC and information about the effect type are available, which reduces the number of possible responsible substances.
Conclusion
This study demonstrates that an oxidation of OTPs by NBS can be applied in an HPTLC-Ox-AChE-I approach and leads to a strong increase of the substances’ inhibition potential and therefore a better sensitivity of the method. Chemical oxidation by NBS mimics the natural activation of OTPs in a more simple and robust manner than biological approaches, which allows a rapid investigation of neurotoxicity. The formation of different products than the corresponding oxons and the temporal processes and pathways during the oxidation should be investigated in detail for example by comparing dose–response relations of oxons that undergo the oxidation process or not. The comparison of the two main application methods for AChE on HPTLC plates, immersion and spraying, showed slight differences in sensitivity and precision. Both methods are suitable for the presented HPTLC-Ox-AChE-I approach. The potential of the spray approach for higher sensitivities should be refined. It may be reasonable to replace the manual spray approach by an automated device. The automation of the entire workflow may increase the reproducibility and comparability and in addition could save time and material. In conclusion, the combination of sample enrichment by SPE, separation by HPTLC, oxidation of possible OTPs, and AChE-I effect testing can be used to investigate neurotoxic activities in surface water samples. The overall workflow should be used to monitor these effects in the aquatic environment in more extensive studies and for the clarification of unknown effect responsible substances in combination with further instrumental analysis.
Data availability
The datasets generated during and analyzed during the current study are available from the corresponding author on reasonable request.
Code availability
Not applicable.
References
Sharma A, Kumar V, Shahzad B, Tanveer M, Sidhu GPS, Handa N, Kohli SK, Yadav P, Bali AS, Parihar RD, Dar OI, Singh K, Jasrotia S, Bakshi P, Ramakrishnan M, Kumar S, Bhardwaj R, Thukral AK. Worldwide pesticide usage and its impacts on ecosystem. SN Applied Sciences. 2019;1(11). https://doi.org/10.1007/s42452-019-1485-1.
Pietrzak D, Kania J, Malina G, Kmiecik E, Wątor K. Pesticides from the EU First and Second Watch Lists in the Water Environment. CLEAN–Soil, Air, Water. 2019;47(7):1800376. https://doi.org/10.1002/clen.201800376.
Singer H, Jaus S, Hanke I, Lück A, Hollender J, Alder AC. Determination of biocides and pesticides by on-line solid phase extraction coupled with mass spectrometry and their behaviour in wastewater and surface water. Environ Pollut. 2010;158(10):3054–64. https://doi.org/10.1016/j.envpol.2010.06.013.
Wittmer IK, Bader HP, Scheidegger R, Singer H, Lück A, Hanke I, Carlsson C, Stamm C. Significance of urban and agricultural land use for biocide and pesticide dynamics in surface waters. Water Res. 2010;44(9):2850–62. https://doi.org/10.1016/j.watres.2010.01.030.
Bollmann UE, Tang C, Eriksson E, Jönsson K, Vollertsen J, Bester K. Biocides in urban wastewater treatment plant influent at dry and wet weather: concentrations, mass flows and possible sources. Water Res. 2014;60:64–74. https://doi.org/10.1016/j.watres.2014.04.014.
Burkhardt M, Zuleeg S, Vonbank R, Schmid P, Hean S, Lamani X, Bester K, Boller M. Leaching of additives from construction materials to urban storm water runoff. Water Sci Technol. 2011;63(9):1974–82. https://doi.org/10.2166/wst.2011.128.
Bollmann UE, Minelgaite G, Schlüsener M, Ternes T, Vollertsen J, Bester K. Leaching of terbutryn and its photodegradation products from artificial walls under natural weather conditions. Environ Sci Technol. 2016;50(8):4289–95. https://doi.org/10.1021/acs.est.5b05825.
Chawla P, Kaushik R, Shiva Swaraj VJ, Kumar N. Organophosphorus pesticides residues in food and their colorimetric detection. Environmental Nanotechnology, Monitoring & Management. 2018;10:292–307. https://doi.org/10.1016/j.enmm.2018.07.013.
Sidhu GK, Singh S, Kumar V, Dhanjal DS, Datta S, Singh J. Toxicity, monitoring and biodegradation of organophosphate pesticides: a review. Crit Rev Environ Sci Technol. 2019;49(13):1135–87. https://doi.org/10.1080/10643389.2019.1565554.
de Souza RM, Seibert D, Quesada HB, de Jesus BF, Fagundes-Klen MR, Bergamasco R. Occurrence, impacts and general aspects of pesticides in surface water: a review. Process Saf Environ Prot. 2020;135:22–37. https://doi.org/10.1016/j.psep.2019.12.035.
Roberts TR, Hutson DH, editors. metabolic pathways of agrochemicals. Part 2: insecticides and fungicides. Cambridge: The Royal Society of Chemistry; 1999.
Sultatos LG. Mammalian toxicology of organophosphorus pesticides. J Toxicol Environ Health. 1994;43(3):271–89. https://doi.org/10.1080/15287399409531921.
Fukuto TR. Mechanism of action of organophosphorus and carbamate insecticides. Environ Health Perspect. 1990;87:245–54.
Songa EA, Okonkwo JO. Recent approaches to improving selectivity and sensitivity of enzyme-based biosensors for organophosphorus pesticides: a review. Talanta. 2016;155:289–304. https://doi.org/10.1016/j.talanta.2016.04.046.
Ellman GL, Courtney KD, Andres V Jr, Featherstone RM. A new and rapid colorimetric determination of acetylcholinesterase activity. Biochem Pharmacol. 1961;7:88–95.
Doctor BP, Toker L, Roth E, Silman I. Microtiter assay for acetylcholinesterase. Anal Biochem. 1987;166:399–403.
Worek F, Eyer P, Thiermann H. Determination of acetylcholinesterase activity by the Ellman assay: a versatile tool for in vitro research on medical countermeasures against organophosphate poisoning. Drug Test Anal. 2012;4(3–4):282–91. https://doi.org/10.1002/dta.337.
Van Dyk JS, Pletschke B. Review on the use of enzymes for the detection of organochlorine, organophosphate and carbamate pesticides in the environment. Chemosphere. 2011;82(3):291–307. https://doi.org/10.1016/j.chemosphere.2010.10.033.
Ackermann H. Dünnschichtchromatographischer-Enzymatischer Nachweis Phosphororganischer Insektizide. Aktivierung schwacher Esterasehemmer. J Chromatogr. 1968;36:309–17.
Mendoza CE, Wales PJ, McLeod HA, McKinley WP. Enzymatic detection of ten organophosphorus pesticides and carbaryl on thin-layer chromatograms: an evaluation of indoxyl, substituted indoxyl and 1-naphthyl acetates as substrates of esterases. Analyst. 1968;93:33–8.
Akkad R, Schwack W. Multi-enzyme inhibition assay for the detection of insecticidal organophosphates and carbamates by high-performance thin-layer chromatography applied to determine enzyme inhibition factors and residues in juice and water samples. J Chromatogr B Analyt Technol Biomed Life Sci. 2010;878(17–18):1337–45. https://doi.org/10.1016/j.jchromb.2009.12.021.
Stütz L, Weiss SC, Schulz W, Schwack W, Winzenbacher R. Selective two-dimensional effect-directed analysis with thin-layer chromatography. J Chromatogr A. 2017;1524:273–82. https://doi.org/10.1016/j.chroma.2017.10.009.
Stütz L, Schulz W, Winzenbacher R. Identification of acetylcholinesterase inhibitors in water by combining two-dimensional thin-layer chromatography and high-resolution mass spectrometry. J Chromatogr A. 2020;1624: 461239. https://doi.org/10.1016/j.chroma.2020.461239.
Chandana N, Morlock GE. Comprehensive bioanalytical multi-imaging by planar chromatography in situ combined with biological and biochemical assays highlights bioactive fatty acids in abelmosk. Talanta. 2021;223(Pt 1): 121701. https://doi.org/10.1016/j.talanta.2020.121701.
Corni G, Brighenti V, Pellati F, Morlock GE. Effect-directed analysis of bioactive compounds in Cannabis sativa L. by high-performance thin-layer chromatography. J Chromatogr A. 2020;1629:461511. https://doi.org/10.1016/j.chroma.2020.461511.
Oberleitner D, Stütz L, Schulz W, Bergmann A, Achten C. Seasonal performance assessment of four riverbank filtration sites by combined non-target and effect-directed analysis. Chemosphere. 2020;261: 127706. https://doi.org/10.1016/j.chemosphere.2020.127706.
Sobstyl E, Szopa A, Ekiert H, Gnat S, Typek R, Choma IM. Effect directed analysis and TLC screening of Schisandra chinensis fruits. J Chromatogr A. 2020;1618: 460942. https://doi.org/10.1016/j.chroma.2020.460942.
Weiss SC, Egetenmeyer N, Schulz W. Coupling of in vitro bioassays with planar chromatography in effect-directed analysis. Adv Biochem Eng Biotechnol. 2017;157:187–224. https://doi.org/10.1007/10_2016_16.
Singh BK, Walker A. Microbial degradation of organophosphorus compounds. FEMS Microbiol Rev. 2006;30(3):428–71. https://doi.org/10.1111/j.1574-6976.2006.00018.x.
Shemer H, Linden KG. Degradation and by-product formation of diazinon in water during UV and UV/H(2)O(2) treatment. J Hazard Mater. 2006;136(3):553–9. https://doi.org/10.1016/j.jhazmat.2005.12.028.
Kralj MB, Cernigoj U, Franko M, Trebse P. Comparison of photocatalysis and photolysis of malathion, isomalathion, malaoxon, and commercial malathion–products and toxicity studies. Water Res. 2007;41(19):4504–14. https://doi.org/10.1016/j.watres.2007.06.016.
Mendoza CE, Wales PJ, Grant DL, McCully KA. Effect of bromine and ultraviolet light on eight pesticides detected with liver esterases of five species. J AGR FOOD CHEM. 1969;17(6):1196–8.
Akkad R, Schwack W. Effect of bromine oxidation on high-performance thin-layer chromatography multi-enzyme inhibition assay detection of organophosphates and carbamate insecticides. J Chromatogr A. 2011;1218(19):2775–84. https://doi.org/10.1016/j.chroma.2011.02.029.
Azadniya E, Mollergues J, Stroheker T, Billerbeck K, Morlock GE. New incorporation of the S9 metabolizing system into methods for detecting acetylcholinesterase inhibition. Anal Chim Acta. 2020;1129:76–84. https://doi.org/10.1016/j.aca.2020.06.033.
Roepcke CB, Muench SB, Schulze H, Bachmann TT, Schmid RD, Hauer B. Analysis of phosphorothionate pesticides using a chloroperoxidase pretreatment and acetylcholinesterase biosensor detection. J Agric Food Chem. 2010;58(15):8748–56. https://doi.org/10.1021/jf1013204.
Schulze H, Schmid RD, Bachmann TT. Activation of phosphorothionate pesticides based on a cytochrome P450 BM-3 (CYP102 A1) mutant for expanded neurotoxin detection in food using acetylcholinesterase biosensors. Anal Chem. 2004;76:1720–5. https://doi.org/10.1021/ac035218t.
Kralj MB, Trebše P, Franko M. Oxidation as a pre-step in determination of organophosphorus compounds by the AChE-TLS bioassay. Acta Chim Slov. 2006;53:43–51.
Deutsches Institut für Normung. DIN 38415–1. German standard methods for the examination of water, waste water and sludge - sub-animal testing (group T) - part 1: determination of cholinesterase inhibiting organophosphorus and carbamate pesticides (cholinesterase inhibition test) (T 1). Berlin: Beuth; 1995.
Azadniya E, Morlock GE. Automated piezoelectric spraying of biological and enzymatic assays for effect-directed analysis of planar chromatograms. J Chromatogr A. 2019;1602:458–66. https://doi.org/10.1016/j.chroma.2019.05.043.
Baetz N, Rothe L, Wirzberger V, Sures B, Schmidt TC, Tuerk J. High-performance thin-layer chromatography in combination with a yeast-based multi-effect bioassay to determine endocrine effects in environmental samples. Anal Bioanal Chem. 2021;413(5):1321–35. https://doi.org/10.1007/s00216-020-03095-5.
Schoenborn A, Schmid P, Bräm S, Reifferscheid G, Ohlig M, Buchinger S. Unprecedented sensitivity of the planar yeast estrogen screen by using a spray-on technology. J Chromatogr A. 2017;1530:185–91. https://doi.org/10.1016/j.chroma.2017.11.009.
Weins C, Jork H. Toxicological evaluation of harmful substances by in situ enzymatic and biological detection in high-performance thin-layer chromatography. J Chromatogr A. 1996;750:403–7. https://doi.org/10.1016/0021-9673(96)00601-2.
Barber D, Correll L, Ehrich M. Comparison of two in vitro activation systems for protoxicant organophosphorus esterase inhibitors. Toxicol Sci. 1999;47:16–22.
Sams C, Mason HJ, Rawbone R. Evidence for the activation of organophopsphate pesticides by cytochromes P450 3A4 and 2D6 in human liver microsomes. Toxicol Lett. 2000;116:217–21.
Tang J, Cao Y, Rose RL, Brimfield AA, Dai D, Goldstein JA, Hodgson E. Metabolism of chlorpyrifos by human cytochrome P450 isoforms and human, mouse, and rat liver microsomes. Drug Metab Dispos. 2001;29(9):1201–4.
Hernandez J, Robledo NR, Velasco L, Quintero R, Pickard MA, Vasquez-Duhalt R. Chloroperoxidase-mediated oxidation of organophosphorus pesticides. Pestic Biochem Physiol. 1998;61:87–94.
Bergmann AJ, Simon E, Schifferli A, Schönborn A, Vermeirssen ELM. Estrogenic activity of food contact materials-evaluation of 20 chemicals using a yeast estrogen screen on HPTLC or 96-well plates. Anal Bioanal Chem. 2020;412(19):4527–36. https://doi.org/10.1007/s00216-020-02701-w.
Acknowledgements
Financial support for the graduate program Future Water by Ministry of Culture and Science of the Federal State of North Rhine-Westphalia (MKW NRW, Düsseldorf, Germany) is gratefully acknowledged.
Gratefully acknowledged is the support of Prof. Dr. Grünebaum from the Ruhrverband (Essen, Germany). We would like to thank also Max Jochums, Martin Klaßen, and Dr. Thorsten Teutenberg (all also from IUTA, Duisburg, Germany) for their inspiration in coming up with ideas for the oxidation process and especially Max Jochums for carrying out initial investigations in the not reported assay format.
Funding
Open Access funding enabled and organized by Projekt DEAL. This study received funding from the graduate program Future Water by the Ministry of Culture and Science of the Federal State of North Rhine-Westphalia (MKW NRW, Düsseldorf, Germany).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethics approval
Not applicable.
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Baetz, N., Schmidt, T.C. & Tuerk, J. High-performance thin-layer chromatography in combination with an acetylcholinesterase-inhibition bioassay with pre-oxidation of organothiophosphates to determine neurotoxic effects in storm, waste, and surface water. Anal Bioanal Chem 414, 4167–4178 (2022). https://doi.org/10.1007/s00216-022-04068-6
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-022-04068-6