Abstract
Accurate quantitation of aldosterone is clinically important in standardized testing for primary aldosteronism. The results are often variable when performed by clinical immunoassays. To standardize and ensure the accuracy of clinical systems, reference measurement procedures (RMPs) with higher metrological order are required. A simple and reliable isotope dilution LC-IDMS/MS-based measurement procedure for human plasma aldosterone has been developed. This method involved plasma spiked with a deuterium-labelled internal standard, equilibrated for 0.5 h, and extracted by liquid-liquid extraction (LLE) without derivatization. Aldosterone and its structural analogues were baseline separated with a C18-packed UHPLC column with gradient elution within 7 min. The signal intensity variability and measurement imprecision were reduced by bracketing calibration during plasma aldosterone value assignment. The limit of detection (LoD) was 19.4 pmol/L with a signal-to-noise ratio (S/N) > 3. The lowest limit of quantification (LLoQ) was 27.7 pmol/L (S/N > 10 and CV < 10.0%). LLE was performed with 1 mL of n-hexane/ethyl acetate (3:2, v/v), and the extraction recovery was determined to be 92.15 ± 3.54%. The imprecisions were ≤ 3.18% for samples at 124.8, 867.0, and 2628.5 pmol/L. The recoveries were 98.11–101.61%. The relative bias between this candidate RMP and the established RMP was 2.76–1.89%. The linearity response ranged from 27.7 to 2774.4 pmol/L with R2 = 0.999. The method performance met the requirements of RMPs (≤ 5% total CV and ≤ 3% bias). Furthermore, the developed method was applied to evaluate immunoassays through 41 patient sample comparisons. The calibration and measurement capability (CMC) of this method were also evaluated by measuring these samples. The candidate RMP can serve as an accurate reference baseline for routine methods and can be used for value assignment for reference materials.
Graphical abstract
Similar content being viewed by others
Abbreviations
- LC-MS/MS:
-
Liquid chromatography/tandem mass spectrometry
- RMP:
-
Reference measurement procedure
- LoD:
-
Limit of detection
- LLoQ:
-
Lowest limit of quantification
- EQA:
-
External quality assessment
- JCTLM:
-
Joint Committee for Traceability in Laboratory Medicine
- IFCC:
-
International Federation of Clinical Chemistry and Laboratory Medicine
- RELA:
-
IFCC External Quality assessment scheme for Reference Laboratories in Laboratory Medicine
- CMC:
-
Calibration and measurement capability
References
Burrello J, Buffolo F, Domenig O, Tetti M, Pecori A, Monticone S, et al. Renin-angiotensin-aldosterone system triple-a analysis for the screening of primary aldosteronism. Hypertension. 2020;75(1):163–72.
Toda N, Nakanishi S, Tanabe S. Aldosterone affects blood flow and vascular tone regulated by endothelium-derived NO: therapeutic implications. Br J Pharmacol. 2013;168(3):519–33.
Burrello J, Monticone S, Buffolo F, Lucchiari M, Tetti M, Rabbia F, et al. Diagnostic accuracy of aldosterone and renin measurement by chemiluminescent immunoassay and radioimmunoassay in primary aldosteronism. J Hypertens. 2016;34(5):920–7.
Pizzolo F, Salvagno G, Caruso B, Cocco C, Zorzi F, Zaltron C, et al. Fully automated chemiluminescence vs RIA aldosterone assay in primary aldosteronism work-up. J Hum Hypertens. 2017;31(12):826–30.
Schirpenbach C, Seiler L, Maser-Gluth C, Beuschlein F, Reincke M, Bidlingmaier M. Automated chemiluminescence-immunoassay for aldosterone during dynamic testing: comparison to radioimmunoassays with and without extraction steps. Clin Chem. 2006;52(9):1749–55.
Stowasser M, Gordon RD. Aldosterone assays: an urgent need for improvement. Clin Chem. 2006;52(9):1640–2.
Panteghini M. Traceability as a unique tool to improve standardization in laboratory medicine. Clin Biochem. 2009;42(4–5):236–40.
International Organization for Standardization (ISO). In vitro diagnostic medical devices — requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples. Geneva: ISO; 2019. ISO 17511
Zhang Q, Cai Z, Liu Y, Lin H, Wang Q, Yan J, et al. Comparison of bracketing calibration and classical calibration curve quantification methods in establishing a candidate reference measurement procedure for human serum 17β-estradiol by isotope dilution liquid chromatography tandem mass spectrometry. Microchem J. 2020;152:104270.
Botelho JC, Ribera A, Cooper HC, Vesper HW. Evaluation of an isotope dilution HPLC tandem mass spectrometry candidate reference measurement procedure for total 17-beta estradiol in human serum. Anal Chem. 2016;88(22):11123–9.
Zhang Q, Zhang L, Lin H, Cai Z, Yan J, Wang Q, et al. Evaluation of a bracketing calibration-based isotope dilution liquid chromatography–tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma. Anal Bioanal Chem. 2019;411(27):7095–104.
Stepman HC, Vanderroost A, Van Uytfanghe K, Thienpont LM. Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry. Clin Chem. 2011;57(3):441–8.
Huang X, Zhang Q, Zheng S, Wang J, Han L, Lin H, et al. Measurement of human serum unconjugated estriol without derivatization using liquid chromatography-tandem mass spectrometry candidate reference method and compared with two immunoassays. Anal Bioanal Chem. 2018;410(24):6257–67.
Joint Committee for Traceability of Laboratory Measurements (JCTLM). Database of higher order reference materials, measurement methods/procedures and services. http://www.bipm.org/jctlm/. Accessed Jan 2020
Turpeinen U, Hämäläinen E, Stenman U. Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry. J Chromatogr B. 2008;862(1–2):113–8.
Taylor PJ, Cooper DP, Gordon RD, Stowasser M. Measurement of aldosterone in human plasma by semiautomated HPLC–tandem mass spectrometry. Clin Chem. 2009;55(6):1155–62.
Hinchliffe E, Carter S, Owen LJ, Keevil BG. Quantitation of aldosterone in human plasma by ultra high performance liquid chromatography tandem mass spectrometry. J Chromatogr B. 2013;913-914:19–23.
Van Der Gugten JG, Dubland J, Liu HF, Wang A, Joseph C, Holmes DT. Determination of serum aldosterone by liquid chromatography and tandem mass spectrometry: a liquid-liquid extraction method for the ABSCIEX API-5000 mass spectrometry system. J Clin Pathol. 2012;65(5):457–62.
Peitzsch M, Dekkers T, Haase M, Sweep FCGJ, Quack I, Antoch G. An LC–MS/MS method for steroid profiling during adrenal venous sampling for investigation of primary aldosteronism. J Steroid Biochem Mol Biol. 2015;145:75–84.
CLSI. Preliminary evaluation of quantitative clinical laboratory methods; approved guideline. 3rd ed. Wayne: CLSI; 2014. CLSI document EP10-A3
ISO/IEC Guide 98–3:2008 Uncertainty of measurement – part 3: guide to the expression of uncertainty in measurement (GUM: 1995)
Zhang Q, Han L, Wang J, Lin H, Ke P, Zhuang J, et al. Simultaneous quantitation of endogenous estrone, 17beta-estradiol, and estriol in human serum by isotope-dilution liquid chromatography-tandem mass spectrometry for clinical laboratory applications. Anal Bioanal Chem. 2017;409(10):2627–38.
CLSI. Liquid chromatography-mass spectrometry methods; approved guideline. Wayne: CLSI; 2014. CLSI document C62-A
Stockl D, Sluss PM, Thienpont LM. Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin D analysis. Clin Chim Acta. 2009;408(1–2):8–13.
Fraser CG, Kallner A, Kenny D, Petersen PH. Introduction: strategies to set global quality specifications in laboratory medicine. Scand J Clin Lab Invest. 1999;59(7):477–8.
Thienpont LM. Quality specifications for reference methods. Scand J Clin Lab Invest. 1999;59(7):535–8.
Stockl D, Reinauer H. Development of criteria for the evaluation of reference method values. Scand J Clin Lab Invest Suppl. 1993;212:16–8.
Tan X, Li F, Wang X, Wang Y. Quantitation and clinical evaluation of plasma aldosterone by ultra-performance liquid chromatography-mass spectrometry. J Chromatogr A. 2020;4(1609):46045.
Funding
Funding was provided by The Natural Science Foundation of Guangdong Province (2020A1515010668), the Specific Research Fund for TCM Science and Technology of Guangdong Provincial Hospital of Chinese Medicine (YN2016QJ06, YN2019QL01, and YN2019 MJ04), and Administration of Traditional Chinese Medicine Bureau of Guangdong Province (20211150).
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
Research involving human participants and/or animals
The research involved plasma samples taken from pregnant women and this study is approved by Ethics Committee of Second Affiliated Hospital of Guangzhou University of Chinese Medicine. The number of this Review is B2016-157-01.
Informed consent
The ethics committee approved the exemption of informed consent.
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
ESM 1
(PDF 211 kb)
Rights and permissions
About this article
Cite this article
Zhang, Q., Han, L., Zheng, S. et al. An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma. Anal Bioanal Chem 413, 4471–4481 (2021). https://doi.org/10.1007/s00216-021-03405-5
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-021-03405-5