Abstract
A primary focus in liquid chromatography analysis of complex samples is high peak capacity separations. Using advanced instrumentation and optimal small, high-efficiency columns, complex multicomponent mixtures can now be analyzed in relatively short times. Despite these advances, chromatographic peak overlap is still observed. Recently, attention has shifted from improvements in chromatographic efficiency and selectivity to enhancing data processing after collection. Curve fitting methods can be used to trace underlying peaks, but do not directly enhance chromatographic resolution. Methods based on the properties of derivatives and power transform were recently shown to enhance chromatographic peak resolution while maintaining critical peak information (peak areas and retention times). These protocols have been extensively investigated for their fundamental properties, advantages, and limitations, but they have not been evaluated with complex chromatograms. Herein, we evaluate the use of deconvolution via Fourier transform (FT), even-derivative peak sharpening, and power law with the fast separation (< 60 s) of a 101-component mixture using ultra-high-pressure liquid chromatography. High noise and peak overlap are present in this gradient separation, which is representative of fast chromatography. Chromatographic resolution enhancement is demonstrated and described. Further, accurate quantitation is maintained and shown with representative examples. Enhancements in peak capacity and peak-to-peak resolutions are discussed. Finally, the statistical theory of overlap is used for 101 peaks and predictions are made for the number of singlet, doublet, and multiplets analyte peaks. The effect of increasing peak capacity by FT even derivative sharpening and power laws leads to a decrease in the number of peak overlaps and an increase in total peak number.
Similar content being viewed by others
References
Patel DC, Breitbach ZS, Wahab MF, Barhate CL, Armstrong DW. Gone in seconds: praxis, performance, and peculiarities of ultrafast chiral liquid chromatography with superficially porous particles. Anal Chem. 2015;87:9137–48.
Patel DC, Wahab MF, Armstrong DW, Breitbach ZS. Advances in high-throughput and high-efficiency chiral liquid chromatographic separations. J Chromatogr A. 2016;1467:2–18.
Barhate CL, Joyce LA, Makarov AA, Zawatzky K, Bernardoni F, Schafer WA, et al. Ultrafast chiral separations for high throughput enantiopurity analysis. Chem Commun. 2016;53:509–12.
Barhate CL, Wahab MF, Breitbach ZS, Bell DS, Armstrong DW. High efficiency, narrow particle size distribution, sub-2 μm based macrocyclic glycopeptide chiral stationary phases in HPLC and SFC. Anal Chim Acta. 2015;898:128–37.
Wahab MF, Wimalasinghe RM, Wang Y, Barhate CL, Patel DC, Armstrong DW. Salient sub-second separations. Anal Chem. 2016;88:8821–6.
Spudeit DA, Dolzan MD, Breitbach ZS, Barber WE, Micke GA, Armstrong DW. Superficially porous particles vs. fully porous particles for bonded high performance liquid chromatographic chiral stationary phases: isopropyl cyclofructan 6. J Chromatogr A. 2014;1363:89–95.
Wahab MF, Patel DC, Wimalasinghe RM, Armstrong DW. Fundamental and practical insights on the packing of modern high-efficiency analytical and capillary columns. Anal Chem. 2017;89:8177–91.
Hellinghausen G, Roy D, Lee JT, Wang Y, Weatherly CA, Lopez DA, et al. Effective methodologies for enantiomeric separations of 150 pharmacology and toxicology related 1°, 2°, and 3° amines with core-shell chiral stationary phases. J Pharm Biomed Anal. 2018;155:70–81.
Patel DC, Wahab MF, O’Haver TC, Armstrong DW. Separations at the speed of sensors. Anal Chem. 2018;90:3349–56.
Ciogli A, Ismail OH, Mazzoccanti G, Villani C, Gasparrini F. Enantioselective ultra high performance liquid and supercritical fluid chromatography: the race to the shortest chromatogram. J Sep Sci. 2019;41:1307–18.
Catani M, Ismail OH, Gasparrini F, Antonelli M, Pasti L, Marchetti N, et al. Recent advancements and future directions of superficially porous chiral stationary phases for ultrafast high-performance enantioseparations. Analyst. 2017;142:555–66.
Khundadze N, Pantsulaia S, Fanali C, Farkas T, Chankvetadze B. On our way to sub-second separations of enantiomers in high-performance liquid chromatography. J Chromatogr A. 2018;1572:37–43.
Barhate CL, Regalado EL, Contrella ND, Lee J, Jo J, Makarov AA, et al. Ultrafast chiral chromatography as the second dimension in two-dimensional liquid chromatography experiments. Anal Chem. 2017;89:3545–53.
Wahab MF, Dasgupta PK, Kadjo AF, Armstrong DW. Sampling frequency, response times and embedded signal filtration in fast, high efficiency liquid chromatography: a tutorial. Anal Chim Acta. 2016;907:31–44.
Barhate CL, Wahab MF, Tognarelli DJ, Berger TA, Armstrong DW. Instrumental idiosyncrasies affecting the performance of ultrafast chiral and achiral sub/supercritical fluid chromatography. Anal Chem. 2016;88:8864–672.
Hellinghausen G, Readel ER, Wahab MF, Lee JT, Lopez DA, Weatherly CA, et al. Mass spectrometry-compatible enantiomeric separations of 100 pesticides using core–shell chiral stationary phases and evaluation of iterative curve fitting models for overlapping peaks. Chromatographia. 2019;82:221–33.
Hellinghausen G, Wahab MF, Armstrong DW. Improving visualization of trace components for quantification using a power law based integration approach. J Chromatogr A. 2018;1574:1–8.
Wahab MF, O’Haver TC, Gritti F, Hellinghausen G, Armstrong DW. Increasing chromatographic resolution of analytical signals using derivative enhancement approach. Talanta. 2019;192:492–9.
Wahab MF, Gritti F, O’Haver TC, Hellinghausen G, Armstrong DW. Chromatographia. 2019;82:211–20.
Wahab MF, Hellinghausen G, Armstrong DW. Progress in peak processing. LC GC Eur. 2019;32:22–8.
Vanderheyden Y, Broeckhoven K, Desmet G. Peak deconvolution to correctly assess the band broadening of chromatographic columns. J Chromatogr A. 2016;1465:126–42.
Savitzky A, Golay MJE. Smoothing and diffraction of data by simplified least squares procedures. Anal Chem. 1964;36:1627–39.
Cook DW, Rutan SC, Stoll DR, Venkatramani C. Peak purity in liquid chromatography, part II: potential of curve resolution techniques. LC GC N Am. 2018;36:248–55.
Wahab MF, Berthod A, Armstrong DW. Extending the power transform approach for recovering areas of overlapping peaks. J Sep Sci. 2019; 42:3604–3610.
Shalliker RA, Stevenson PG, Shock D, Mnatsakanyan M, Dasgupta PK, Guiochon G. Application of power functions to chromatographic data for the enhancement of signal to noise ratios and separation resolution. J Chromatogr A. 2010;1217:5693–9.
Dasgupta PK, Chen Y, Serrano CA, Guiochon G, Liu H, Fairchild JN, et al. Black box linearization for greater linear dynamic range: the effect of power transforms on the representation of data. Anal Chem. 2010;82:10143–50.
Gilar M, Daly AE, Kele M, Neue UD, Gelber JC. Implications of column peak capacity on the separation of complex peptide mixtures in single-and two-dimensional high-performance liquid chromatography. J Chromatogr A. 2004;1061:183–92.
Giddings JC. Unified separation science. New York: John Wiley & Sons, Inc.; 1991.
Davis JM, Giddings JC. Statistical theory of component overlap in multicomponent chromatograms. Anal Chem. 1983;55:418–24.
Acknowledgments
We thank Dr. Fabrice Gritti from Waters Corporation (Milford, MA, USA) for the gift of the CORTECS T3 columns and helpful discussions.
Funding
This work was supported by the Robert A. Welch Foundation (Y0026).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
ESM1
(PDF 109 kb)
Rights and permissions
About this article
Cite this article
Hellinghausen, G., Wahab, M.F. & Armstrong, D.W. Improving peak capacities over 100 in less than 60 seconds: operating above normal peak capacity limits with signal processing. Anal Bioanal Chem 412, 1925–1932 (2020). https://doi.org/10.1007/s00216-020-02444-8
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-020-02444-8