1 Translating Imaging of Cardiac Function to Small Animals

Our current approaches to the study of cardiac function and the mechanisms that regulate it in both healthy and disease states rely heavily on biochemical assays of the expression of genes and proteins, extracted from some part of the myocardium. However, we know from studies of the anatomy and physiology of the heart over the past two centuries that in many regards the heart is far from uniform across different regions in its function from the cell to tissue levels. It is easy to forget, when considering molecular analyses, that heart disease too is more often than not, non-uniform in the way it affects the coronary vessels and cardiac muscle. The assessment of myocardial contractile-relaxation properties and coronary vascular function in specific regions of the heart in humans and large experimental animals are two areas in fundamental cardiovascular science and clinical diagnosis that have been greatly aided by the application of various invasive biophysical sensors and non-invasive or less invasive imaging techniques. However, rodents and in particular transgenic mice, are the most common subjects utilized for basic cardiovascular science to discover the mechanisms of disease development and progression and the efficacy of pharmacological and regenerative interventions. Nonetheless, the small physical size of the rodent heart and limitations in the spatial and or temporal resolution of many of the traditional techniques employed to study cardiac and coronary function has previously limited such assessments to global measures. Frequently, it has not been possible to make repeated measurements in the same animals in the past.

Herein, we describe our recent progress in the development of in vivo imaging approaches that permit repeated measurements of coronary vascular function utilizing microangiography and local cardiac actin-myosin cross-bridge dynamics utilizing synchrotron radiation (SR) based small angle X-ray scattering (SAXS). This combination of techniques is being used to investigate the important role of the coronary microcirculation in the origins of myocardial disease associated with diabetes, hypertension, obesity and heart failure. For detailed overviews of the cardiovascular application of these techniques, their merits and limitations, the reader is referred to our reviews on synchrotron imaging applications (Shirai et al. 2009, 2013). The high intensity X-ray radiation obtainable at third and fourth generation synchrotron facilities around the world is essential for in situ SAXS recordings from the beating heart in anaesthetised rodents. Lab X-ray sources, routinely used for protein crystallography and SAXS studies of ex vivo samples do not produce sufficient photon flux to enable in vivo recordings with the resolution of several milliseconds. While microangiography performed with SR tuned to energies selective for the elements of contrast imaging agents (such as iodine) facilitates the highest possible temporal and spatial resolution for vascular imaging (see Sect. 15.2.1), the current capabilities of optimized microfocus X-ray systems now permits in vivo imaging of microvessels and has some applications for coronary imaging. Our progress in this area is briefly presented in this chapter (see Sect. 15.3). Before describing how we can apply SAXS and microangiography in our ongoing studies in rats and now mice, we first discuss the motivation for utilizing these techniques.

Synchrotron facilities with the capability of biomedical imaging, including the techniques described in this chapter, are available in many continents. The Lightsources.org webpages (http://www.lightsources.org/) is a useful community based entry point for explanations of synchrotron radiation principles, recent applications and descriptions of the synchrotron facilities available worldwide for non-commercial and commercial research. These webpages also describe access programs for each of these facilities.

2 The Importance of the Microvessels in Sustaining Cardiac Function

Conduit arteries, which includes the large main left and right coronary arteries and the medium to small artery side branches (>300 μm internal diameter, ID in humans) serve to distribute blood flow to all regions of the heart. However, the intramural resistance vessels, which primarily includes arterioles (<150 μm ID) and to a lesser extent, small arteries, distribute blood within the myocardial tissue. The majority of coronary resistance is produced by the arterioles, and is determined by the calibre (vessel ID) and the extent of deformation of these vessels during systolic contractions (Camici et al. 2012). As can be appreciated from Fig. 15.1, the capillary and arteriole microvessel network of the myocardium is very extensive. Interspersed between the muscle fibres the capillary density varies from a little over 2000/mm2 in mice to more than 3000/mm2 in dogs (Bassingthwaighte et al. 1974; Xu et al. 2016). Notably, utilizing clinical angiography in humans it is not possible to visualize the microvessels. The smallest vessels evident in clinical angiograms are small artery conduit vessels (Fig. 15.2).

Fig. 15.1
figure 1

Ex vivo mouse hearts filled with (a) barium gelatin mixture (angiogram) and (b) Microfil ® resin (microscope image) in the coronary arterial circulations reveals the extraordinary microvessel density within the obvious network of macrovessels. Arrows indicate 30 μm arterioles, which represent the limit of visualization utilising in vivo 2D X-ray angiography

Fig. 15.2
figure 2

Clinical CT (a, b) is not able to resolve microvessels, and the smallest visible vessels observed with clinical angiography (c) are small to medium arteries (>200 μm internal diameter). (Reproduced from Rao and Thompson 2011)

Coronary regulation of the larger microvessels acts to adjust local blood flow to meet metabolic demands. An increase in cardiac work during stress and exercise is facilitated by an increase in coronary flow through the opening of side branches and more distal segments of the vascular tree (vasodilation). The ratio or the maximal increase in coronary flow above resting level is referred to as coronary flow reserve and is a useful index of the health of the coronary circulation. Coronary flow reserve can be determined by positron emission tomography, myocardial contrast echocardiography or invasively with electromagnetic flow probes, cine-angiography or the thermodilution technique. Regardless of the technique used, coronary flow reserve is an integrated measure of blood flow changes across the whole myocardium, including the large coronary arteries and the microvessels, and while very informative, it does not inform on how blood flow is distributed between vessel types or regions. However, direct visualization of coronary vascular responses during cine-angiography does permit analysis of regional changes in blood flow in terms of flow velocity, vessel calibre and visible vessel number. Hence, cine-angiography provides opportunities to investigate changes in coronary function in healthy and disease states.

Various studies now reveal that microvascular function impairment is an important contributor to the progression of many forms of heart failure, including hereditary and non-hereditary forms of hypertrophic cardiomyopathy (Olivotto et al. 2011; Camici et al. 2012), and the increasingly prevalent forms of heart failure with preserved ejection fraction (HFpEF) and angina (Franssen et al. 2016; Crea et al. 2017). There is growing evidence that endothelial dysfunction and ongoing vascular inflammation contribute not only to progressive rarefaction of coronary microvessels (Mohammed et al. 2015), but also increased stiffness and impaired relaxation of cardiac muscle (Franssen et al. 2016; Crea et al. 2017). Reduced nitric oxide bioavailability in the cardiomyocytes surrounding the microvessels is associated with diminished protein kinase G activity and reduced phosphorylation of the giant sarcomeric protein titin, and thus, increased passive tension (one component of muscle stiffening) of the sarcomeres and promotion of ventricular hypertrophy (Borbely et al. 2009; van Heerebeek et al. 2012; Paulus and Tschöpe 2013; Franssen et al. 2016). However, the roles of other vasodilators have not been considered in the current paradigm that links microvessel endothelial inflammation to the origins of HFpEF. It is well established that endothelium derived hyperpolarization factors (EDHF) are important for the regulation of microvessel flow and coronary flow reserve during exercise. Diabetes, obesity, hypertension and aging all impair microvessel EDHF production and or transmission of the hyperpolarization signal through the vessel wall (Park et al. 2008; Luksha et al. 2009; Jenkins et al. 2012; Behringer et al. 2013; Feher et al. 2014; Beyer et al. 2016; Chen et al. 2016; Garland and Dora 2016). Moreover, an imbalance of vasoconstrictor factors, including endothelin-1, rho-kinase and serotonin also contribute to vascular dysfunction in the same comorbidities, which in combination drive the development of HFpEF. Therefore, the roles of other vasodilators and vasoconstrictors in the deterioration of coronary flow reserve, myocardial contractile reserve and diastolic dysfunction remain to be investigated.

2.1 The Challenges Associated with Investigating Coronary Microvascular Function

How then do we assess the presence of endothelial dysfunction, particularly in the microvessels? Conventional cine-angiography using clinical radiography systems does not permit visualization of the coronary microvessels as low photon flux and collimation limit vessel resolution to vessels >200 μm ID (Shirai et al. 2013) (Fig. 15.2). Despite the advances in clinical computed tomography (CT) angiography with dual-energy multidetector systems, these systems still have a spatial resolution less than that of clinical cine-angiography, and therefore only medium to large arteries can be resolved. However, in rodents the coronary arterioles are 40–100 μm ID and can readily be visualized with SR microangiography (Jenkins et al. 2012; Pearson et al. 2017) (Fig. 15.3). This approach facilitates investigations of endothelial and smooth muscle function during pharmacological stimulation in anaesthetised rodents in vivo. The main advantage of this SR cine-angiography approach is that it enables in vivo analysis of vascular function at the same time in multiple arterial vessels across the micro- to macrovessel network under physiological conditions and with intact neurohormonal regulation, which is important for research translation. Further, it is possible to repeat imaging many times during pharmacological stimulation and the manipulation of cardiac loading conditions. An important limitation is the tradeoff for imaging at pixel resolutions of 10–15 μm is that generally available optic chips have arrays of 1024 × 1024 or 2048 × 2048 pixels, limiting the maximum observable field of view to 1–3 cm.

Fig. 15.3
figure 3

Assessment of endothelial function in the coronary circulation in vivo in a male Sprague Dawley rat. (a) baseline vehicle infusion, (b) acetylcholine (ACh) administration, (c) dobutamine administration. Numerals show four branching orders of arterial vessels. ACh and dobutamine stimulation evoked dilation and an increase in visible vessel number (white arrows)

We utilize direct arterial injection of bolus amounts of commercial iodinated contrast agents. The increased viscosity of pure contrast agent requires that contrast be injected with a fast syringe pump via an arterial catheter that is as short as possible to reduce resistance to bolus delivery, and placed as close to target vessels as possible. Typically, paediatric radiography catheters can be used for adult and adolescent rats and hamsters, but for studies utilizing mice then tapered or step-down catheters are essential. Polyethylene or polyurethane catheters with an outer diameter of 1.2F (0.4 mm), such as a cut down version of the FunnelCath™, can successfully deliver contrast agent boluses in mice in ~1 s if the distal narrow tube is shortened (a simple manual test can confirm the ideal length for bolus injection) (Pearson et al. 2017). Furthermore, in the case of coronary angiography in rodents, ideal coronary cine-angiograms can only be obtained if the tip of the catheter is inserted retrograde via the right carotid artery (most direct route) up to a position immediately behind the aortic valve, otherwise left ventricle pumping greatly dilutes contrast concentration and entry into the coronary arteries. When inserting narrow gauge catheters in mice the use of a guidewire is sometimes needed to assist catheter insertion when vascular remodeling makes the artery wall increasingly fragile.

2.2 Protocols for Assessment of Coronary Endothelial Function

As demonstrated in Fig. 15.3 with current X-ray detectors it is possible to acquire coronary angiograms at physiological heart rates (300–700 bpm) free from motion artefacts, even at video frame rates, utilizing shutters placed in the X-ray beam to reduce single frame exposure times to 1–5 ms. High speed detectors operating at 50–100 Hz with high sensitivity phosphor plates eliminate the need for shutters for imaging acquisition, but such shutters serve to reduce surface entry radiation dose when image acquisitions are repeated many times in the same animals. Furthermore, motion-induced artefacts during coronary imaging are nearly eliminated by briefly sustaining lung volume at end inspiration (a breath hold 3–4 s), without significantly altering haemodynamics.

Single frames from cine-sequences acquired from two mice during a drug stimulation protocol (~1 h duration) are illustrated in Fig. 15.4. In this study (Pearson et al. 2017) we examined how the absence of a scavenger receptor class B (SR-B1) protein affected the global and regional regulation of coronary vasodilation in the microcirculation utilizing a transgenic mouse model exposed transiently to a high fat diet, which induces coronary plaque lesion formation. Not only were we able to show that SR cine-angiography could reveal partial occlusions (black arrows in b, stenoses confirmed by histology to be due to occlusive plaque formation, Fig. 15.4) in macrovessels, but also that smooth muscle dysfunction was present globally in non-occluded microvessels (Pearson et al. 2017).

Fig. 15.4
figure 4

Vascular responses to drug stimulation (a) in a mouse with SR-B1 protein present in blood vessels compared with (b) in a mouse deficient in SR-B1 protein. During baseline (A), ACh (B), sodium nitroprusside (C), blockade of nitric oxide and prostaglandins (D), blockade and ACh (E), enlargement of panel E illustrating stenoses (black arrows) in deficient mouse (F). (Reproduced from Pearson et al. 2017)

We have successfully transferred coronary SR cine-angiography protocols to enable assessment of coronary vascular function in normal and transgenic mouse models (Shirai et al. 2013). While assessment of coronary flow reserve can be performed with adenosine or dobutamine stress test in mice, as shown for a rat in Fig. 15.3, it is often desired to assess coronary endothelial function during disease progression and following pharmacological intervention. Two simple protocols are illustrated that allow the assessment of endothelial dysfunction in mice by evaluating the changes in coronary vessel calibre and visible vessel number mediated by endothelium-dependent and independent dilation induced by agonist stimulation (Fig. 15.5). Continuous infusion of acetylcholine (ACh) or bradykinin (BK) solutions (0.1 mg/ml) at flow rates of 3 μl/min in a 30 g mouse or 2 μl/min in a 20 g mouse (10 μg/kg/min) evoke endothelium-dependent dilation. It has been demonstrated many times that ACh and BK can evoke dilation through nitric oxide or endothelium-derived hyperpolarization factors (Batenburg et al. 2004, 2005; Bergaya et al. 2004; Jenkins et al. 2012; Chen et al. 2016). In order to establish whether the lack of a response to ACh stimulation is due to endothelial dysfunction in any given vascular bed it is common practice to subsequently stimulate the vessels with sodium nitroprusside (SNP, 10 μg/kg/min), a nitric oxide donor, after a suitable washout period. SNP evokes endothelium-independent dilation in the absence of smooth muscle dysfunction. Therefore, if a mouse shows dilation to SNP, but not ACh, then this is taken to be evidence of endothelial dysfunction. On the other hand, in models where vessels do not show dilation to SNP then this is taken to be evidence of smooth muscle dysfunction, at least in respect to nitrergic signaling within the smooth muscle. If vessels do not respond with dilation to either ACh or SNP it is not possible to establish that endothelial dysfunction is present since there is underlying smooth muscle dysfunction downstream of the endothelium, unless the same vessels also fail to dilate to BK, which can evoke hyperpolarization independent of nitric oxide. Hence, utilizing multiple endothelium-dependent agonists to investigate endothelial function is recommended where possible. If the presence of smooth muscle dysfunction is indicated by a lack of response to SNP, then further investigation of the mechanism involved can be achieved by also utilizing adenosine or large-conductance Ca2+-activated K+ channel agonists to determine which relaxation mechanisms are dysfunctional (Batenburg et al. 2005).

Fig. 15.5
figure 5

Routine protocols for investigating endothelium-dependent and independent vasodilation in rodents with consecutive drug stimulations

3 Progress in Vascular Imaging of Small Animals with Lab Systems

Preclinical microCT systems are commercially available that enable CT angiography in animals up to the size of rabbits. However, effective pixel size for single projection images on the CMOS flat-panel detectors with a field of view of several cm3 is typically 100–200 μm. With such systems 2D angiography can at best reveal small arteries. Higher resolution acquisitions are only possible for ex vivo 3D acquisitions due to the prolonged scanning times (>5 min). Nonetheless, microfocus X-ray imaging systems are available that are suitable for real time imaging of the microvessels in vivo, but the challenge has been achieving fast imaging with sufficient absorption contrast to visualize vessels in organs that move, the heart and lungs. One such system that we have utilized for investigations of the hindlimb vasculature in peripheral arterial disease associated with diabetes is the Hitex system described in our recent study (Sonobe et al. 2015).

Utilising an optimised microfocus X-ray system (MFX-80HK, Hitex Ltd., Osaka, Japan) incorporating an off the shelf high speed camera with ultrasensitivity (FASTCAM Mini AX200, Photron, Japan) we have greatly improved the possibilities for real time cine-angiography in rats and mice (Fig. 15.6). The current capability of this system suggests that microvessel function studies approach the real resolution of SR microangiography in the hindlimb, brain and renal vessel beds (with frame averaging). However, limited photon counts at the detector result in blur and unsatisfactory vessel edge detection in single projection images of the coronary and pulmonary arteries below 100 μm. Further optimization of the image intensifier and X-ray source might lead to the development of a system that permits assessment of coronary endothelial function in vivo during closed-chest conditions in the laboratory.

Fig. 15.6
figure 6

(a) Microfocus X-ray video system (Hitex, Osaka, Japan) optimized for laboratory based imaging (iodine contrast agent) and examples of image quality achieved while imaging anaesthetised (b) rats (hindlimb, kidney, pulmonary and coronary arteries) and (c) mice (hindlimb), acquired at 250 frames/s, 60 kV and 80 μA. Black arrows indicate 50 μm arterioles in the hindlimb and renal cortex

4 Application of In Vivo SAXS to the Study of Myocardial Function in Mice

Various research groups currently employ SAXS for muscle diffraction studies of contraction-relaxation mechanisms in cardiac muscle ex vivo, which is complemented by cell approaches to investigate excitation-contraction coupling in isolated cardiomyocytes. This can be routinely achieved with dedicated lab X-ray SAXS systems, but real-time analysis of myofilament function is achieved with SR as an X-ray source. We and others have developed approaches for SAXS investigations in the beating heart in situ utilizing rats and more recently mice (Pearson et al. 2004, 2007; Yagi et al. 2004; Toh et al. 2006; Shirai et al. 2013).

Actin and myosin filaments form the bulk of sarcomeric proteins, along with titin, but only the lattice like arrangement of actin-myosin produces diffraction reflections when a high energy X-ray beam (0.1 × 0.2 mm) is aligned perpendicular to the myocardial fibre direction (Shirai et al. 2013). The intensity of the two major reflections produced depends on the electron mass distribution around the filaments, which changes during the cross-bridge cycle as myosin heads shift between the myosin backbone and the surrounding actin filaments (Fig. 15.7). The diffraction pattern acquired at 10–15 ms intervals from a beam passing through the exposed heart of a supine anaesthetised rodent is sufficient to track the changes in myosin mass transfer over the cardiac cycle for several seconds (Pearson et al. 2004). The intensity of the 1,0 reflection decreases as myosin heads are extended towards actin and form force-developing cross-bridge attachments. This myosin mass transfer provides a simple index of the number of cross-bridge attachments formed, which is highly correlated with developed force and left ventricular pressure at systole.

Fig. 15.7
figure 7

In situ small angle X-ray scattering based investigations of regional cardiac contractile function. Diffraction pattern recorded in a 15 ms interval, and a typical intensity profile and the calculated intensity ratio change over the cardiac cycle

In recent years we and others have shown that this in vivo approach can be utilized to investigate regional differences in myocardial function and even differences across the myocardial wall from the epicardium to the subendocardium based on the trajectory of the X-ray beam (Jenkins et al. 2013; Shirai et al. 2013; Waddingham et al. 2015). Using this approach, we showed that altered kinase activity and changes in phosphorylation state of the various myofilaments in diabetes contributes to the early origins of diastolic dysfunction (Fig. 15.8). Further, others have shown with ex vivo SAXS that altered protein kinase activity in cardiac hypertrophy contributes to an increase in passive stiffness associated with more myosin heads remaining in the proximity of actin filaments (Sumita Yoshikawa et al. 2013).

Fig. 15.8
figure 8

(a) Direct relation between rho-kinase (ROCK1) protein expression in the myocardium of rats and (b) the measured diastolic (ED) intensity ratio determined from X-ray diffraction patterns. Results shown include non-diabetic (control) and diabetic rats treated with ROCK inhibitor fasudil. Reproduced from Waddingham et al. (2015)

Since the first SAXS studies on cross-circulated canine hearts, then spontaneously beating rat hearts, there has been only one study that investigated in situ cross-bridge interactions and myosin mass transfer simultaneous with electrocardiogram in the mouse heart (Toh et al. 2006). Now we have been able to apply cardiac muscle diffraction recordings simultaneous with left ventricle pressure-volume recordings in transgenic mice, and again use this approach to measure myosin mass transfer across the cardiac cycle in different layers of the left ventricle (Fig. 15.9). Ongoing studies are now investigating myofilament dysfunction with aging in a knockin mouse model of human familial cardiac hypertrophy. This opens the possibilities of new investigations into cardiomyopathies and heart failure using cell-specific or receptor-ligand specific knock down or knockin and even conditional knockouts to probe the underlying mechanisms associated with myofilament dysfunction due to altered myocardial energetics and calcium overload, changes in intracellular protein kinase signaling or increased myocardial oxidative stress and inflammation.

Fig. 15.9
figure 9

Calculated equatorial reflection intensity ratio over the cardiac cycle in a normal wild type mouse over a 2-s recording (10 ms intervals). red dashed line indicates ratio obtained in the heart arrested in diastole (state with no cross-bridge attachments)