Towards a Mixed-Reality First Person Point of View Needle Navigation System

  • Conference paper
  • First Online:
Medical Image Computing and Computer Assisted Intervention – MICCAI 2019 (MICCAI 2019)

Abstract

Ultrasound-guidance has reduced complications, such as carotid artery punctures, during central venous catherization (CVC). The continued prevalence of these complications has promoted the use of mixed-reality systems for surgical needle navigation. We have developed a surgical navigation system that renders the calibrated ultrasound (US) image and tracked models of the probe, needle and needle-trajectory. We compared the effectiveness of this guidance system on a desktop monitor or within a head-mounted display (HMD) to the US-only approach in a phantom-based user study with 33 expert clinical practitioners. These users performed one needle insertion on each of the two vessel sets within the phantom, where the first insertion was used as training and the second was used for analysis. The guidance system rendered within the HMD significantly improved the safety margin, defined as number of successful needle insertions, where the final needle position was within the lumen of the vessel, as 31 users performed successful insertions with the HMD system compared to 21 successful insertions under US-only guidance. Furthermore, the HMD system significantly improved the distance from the final needle tip to the vessel wall, as clinicians more consistently position the needle such that it was within the vessel lumen but far from the vessel wall when using the HMD system. The clinicians’ performance using the monitor system was comparable to the US-only guidance. Therefore, using a HMD to align the visual and motor fields of the clinician is imperative to successful needle guidance, promoting the continued pursuit of HMD guidance research.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Ameri, G., Baxter, J.S.H., Bainbridge, D., Peters, T.M., Chen, E.C.S.: Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale. Int. J. Comput. Assist. Radiol. Surg. 13(4), 495–505 (2018)

    Article  Google Scholar 

  2. Chao, A., et al.: Performance of central venous catheterization by medical students: a retrospective study of students’ logbooks. BMC Med. Educ. 14(1), 168 (2014)

    Article  Google Scholar 

  3. Chen, E.C.S., Peters, T.M., Ma, B.: Which point-line registration? In: Webster, R.J., Fei, B. (eds.) Proceedings of the SPIE 10135, Medical Imaging 2017: Image-Guided Procedures, Robotic Interventions, and Modeling, p. 1013509 (2017)

    Google Scholar 

  4. Groves, L.A., et al.: Accuracy assessment for the co-registration between optical and VIVE head-mounted display tracking. Int. J. Comput. Assist. Radiol. Surg. 14(7), 1207–1215 (2019)

    Article  Google Scholar 

  5. Hameeteman, M., Bode, A.S., Peppelenbosch, A.G., der Sande, F.M.V., Tordoir, D.J.H.: Ultrasound-guided central venous catheter placement by surgical trainees: a safe procedure? J. Vasc. Access 11(4), 288–292 (2010)

    Article  Google Scholar 

  6. Raad, I.: Intravascular-catheter-related infections. Lancet (Lond. Engl.) 351(9106), 893–898 (1998)

    Article  Google Scholar 

  7. Saugel, B., Scheeren, T.W.L., Teboul, J.L.: Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice. Crit. Care 21(1), 225 (2017)

    Article  Google Scholar 

  8. Soni, N.J., et al.: Use of ultrasound guidance for central venous catheterization: a national survey of intensivists and hospitalists. J. Crit. Care 36, 277–283 (2016)

    Article  Google Scholar 

  9. Surry, K.J.M., Austin, H.J.B., Fenster, A., Peters, T.M.: Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging. Phys. Med. Biol. 49(24), 5529–5546 (2004)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Leah Groves .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Groves, L., Li, N., Peters, T.M., Chen, E.C.S. (2019). Towards a Mixed-Reality First Person Point of View Needle Navigation System. In: Shen, D., et al. Medical Image Computing and Computer Assisted Intervention – MICCAI 2019. MICCAI 2019. Lecture Notes in Computer Science(), vol 11768. Springer, Cham. https://doi.org/10.1007/978-3-030-32254-0_28

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-32254-0_28

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-32253-3

  • Online ISBN: 978-3-030-32254-0

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics