Abstract
Here, we describe an amino acid analysis that is based on the use of hydrophilic interaction liquid chromatography coupled with isotope dilution mass spectrometry for the accurate quantification of underivatized amino acids from hydrolyzed peptide/protein. Twelve underivatized amino acids were separated and detected during an 88-min runtime. The absolute limits of detection and limits of quantification (on column) of the four amino acids (isoleucine, phenylalanine, proline, and valine) were in the range of 6–80 and 20–200 fmol, respectively. As little as 25 pmol of peptide or protein hydrolysates is sufficient for determining absolute content.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Moore S, and Stein WH (1948) Photometric ninhydrin method for use in the chromatography of amino acids. J Biol Chem 176:367–388
Moore S, Spackman DH, and Stein WH (1958) Chromatography of Amino Acids on Sulfonated Polystyrene Resins. An Improved System. Anal. Chem. 30:1185–1190
Benson JR, and Hare PE (1975) O-phthalaldehyde: fluorogenic detection of primary amines in the picomole range. Comparison with fluorescamine and ninhydrin, Proc Natl Acad Sci USA 72:619–622
Cohen SA, and Strydom DJ (1988) Amino acid analysis utilizing phenylisothiocyanate derivatives. Anal Biochem 174:1–16
Molnár-Perl I (1994) Advances in the high-performance liquid chromatographic determination of phenylthiocarbamyl amino acids. J Chromatog A 661:43–50
Cohen SA, and Michaud DP (1993) Synthesis of a fluorescent derivatizing reagent, 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, and its application for the analysis of hydrolysate amino acids via high-performance liquid chromatography. Anal Biochem 211: 279–287
Strydom DJ, and Cohen SA (1994) Comparison of amino acid analyses by phenylisothiocyanate and 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate precolumn derivatization. Anal Biochem 222:19–28
Dell’mour M et al (2010) Hydrophilic interaction LC combined with electrospray MS for highly sensitive analysis of underivatized amino acids in rhizosphere research. J Sep Sci 33:911–922
Burkit, WI et al (2008) Toward Systeme International d’Unite-traceable protein quantification: from amino acids to proteins. Anal Biochem 376:242–251
Kato M et al (2009) Application of amino acid analysis using hydrophilic interaction liquid chromatography coupled with isotope dilution mass spectrometry for peptide and protein quantification. J Chromatogr 877:3059–3064
Woolfitt AR et al (2009) Amino acid analysis of peptides using isobaric-tagged isotope dilution LC-MS/MS. Anal Chem 81:3979–3985
Munoz A, Kral R, and Schimmel H (2010) Quantification of protein calibrants by amino acid analysis using isotope dilution mass spectrometry. Anal Biochem 408:124–131
National Metrology Institute of Japan (2009) Reference Material Certificate, NMIJ CRM 6013–6016
National Metrology Institute of Japan (2008) Reference material certificate, NMIJ CRM 6201
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer Science+Business Media, LLC
About this protocol
Cite this protocol
Kato, M., Takatsu, A. (2012). Amino Acid Analysis by Hydrophilic Interaction Chromatography Coupled with Isotope Dilution Mass Spectrometry. In: Alterman, M., Hunziker, P. (eds) Amino Acid Analysis. Methods in Molecular Biology, vol 828. Humana Press, Totowa, NJ. https://doi.org/10.1007/978-1-61779-445-2_6
Download citation
DOI: https://doi.org/10.1007/978-1-61779-445-2_6
Published:
Publisher Name: Humana Press, Totowa, NJ
Print ISBN: 978-1-61779-444-5
Online ISBN: 978-1-61779-445-2
eBook Packages: Springer Protocols