Skip to main content
Log in

A prototype neutron dose measuring instrument based on prompt gamma detection

  • Regular Article
  • Published:
The European Physical Journal Plus Aims and scope Submit manuscript

Abstract.

Neutron detection and the measurement of ambient dose equivalent are essential to ensure radiation safety in the workplace neutron environment existing in neutron-generating facilities, like particle accelerators, nuclear reactors and other neutron-generating facilities. Based on the measurement of the prompt gammas emitted from elements like hydrogen, boron and carbon, consequent to neutron interactions, a prototype neutron dose measuring instrument has been fabricated using high-density polyethylene and borated high-density polyethylene. This instrument provides an optimized response that closely approximates the fluence to dose conversion coefficients recommended by the International Commission on Radiological Protection (ICRP) to estimate the ambient neutron dose equivalent. Experimental evaluation of the performance of the instrument has been done using neutrons emitted from a 241 Am-Be source, kept inside a concrete enclosure with a square opening on one side. The present system can measure neutron dose with a match of about 5% with theoretical estimates and an existing rem-meter. The measured minimum detection level (MDL) of the instrument is 8.35 μSvh-1 in the presence of significant gamma background and can be improved using a larger NaI(Tl) detector.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P.K. Sarkar, Radiat. Meas. 45, 1476 (2010)

    Article  Google Scholar 

  2. C. Sunil, A.A. Shanbhag, M. Nandy, T. Bandyopadhyay, S.P. Tripathy, C. Lahiri, D.S. Joshi, P.K. Sarkar, Radiat. Prot. Dosim. 143, 4 (2011)

    Article  Google Scholar 

  3. D.T. Bartlet, R.J. Tanner, H. Tagziria, D.H. Thomas, Response characteristics of neutron survey instruments, NRPB-R333(rev) (November 2001) available on http://www.hpa.org.uk/web/HPAwebFile/HPAweb_C/1194947364968

  4. ICRP, Conversion Coefficients for Use in Radiological Protection Against External Radiation, ICRP Publication 74, International Commission on Radiological Protection, Ann. ICRP 26(3-4) (Elesevier Science, Oxford, 1996)

  5. P. Priyada, P.K. Sarkar, Nucl. Instrum. Methods Phys. Res. A 785, 135 (2015)

    Article  ADS  Google Scholar 

  6. P. Priyada, U. Ashwini, P.K. Sarkar, Nucl. Instrum. Methods Phys. Res. A 819, 139 (2016)

    Article  ADS  Google Scholar 

  7. G. Battistoni, S. Muraro, P.R. Sala, F. Cerutti, A. Ferrari, S. Roesler, A. Fasso, J. Ranft, AIP Conf. Proc. 896, 31 (2007)

    Article  ADS  Google Scholar 

  8. A. Fasso, A. Ferrari, J. Ranft, P.R. Sala, FLUKA: a multi-particle transport code, CERN-2005-10, INFN/TC_05/11, SLAC-R-773 (2005)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. K. Sarkar.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Udupi, A., Panikkath, P. & Sarkar, P.K. A prototype neutron dose measuring instrument based on prompt gamma detection. Eur. Phys. J. Plus 133, 318 (2018). https://doi.org/10.1140/epjp/i2018-12131-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1140/epjp/i2018-12131-x

Navigation