Abstract
A package of applied programs for calculating phase-contrast images of three-dimensional samples has been created. The package was applied to model two tomography experiments in medical samples. Using the results of the calculations, the possibilities of the practical application of these methods are discussed.
Similar content being viewed by others
References
V. A. Bushuyev, V. N. Ingal, and E. A. Belyavskaya, Kristallografia 43(4), 586–595 (1998).
A. Snigirev, I. Snigireva, V. Kohn, et al., Rev. Sci. Instrum. 66(12), 5486 (1995).
V. N. Ingal and E. A. Beliaevskaya, J. Phys. D. 28(10), 2314 (1995).
S. W. Wilkins, T. E. Gureyev, D. Gao, et al., Nature 384, 335 (1996).
A. N. Tikhonov, V. Ya. Arsenin, and A. A. Timonov, Mathematical Problems of Computer Tomography (Nauka, Moscow, 1987) [in Russian].
A. C. Kak and A. Slaney, Principles of Computerized Tomographic Imaging (IEEE Press, 1988).
G.W. Faris and R. L. Byer, Applied Optics 27(24), 5202–5212 (1988).
J. W. Goodman, Introduction to Fourier Optics, 2nd Ed. (The McGraw Hill, 1996).
A. Maximenko, Appl. Phys. Lett. 90, 154106 (2007).
L. D. Landau and Ye. M Livshitz, Electrodynamics of Continuous Media (Fizmatlit, Moscow, 2005) [in Russian].
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © S.V. Gasilov, I.V. Gasilova, S.V. Dyachenko, 2012, published in Matematicheskoe Modelirovanie, 2012, Vol. 24, No. 4, pp. 117–128.
Rights and permissions
About this article
Cite this article
Gasilov, S.V., Gasilova, I.V. & Dyachenko, S.V. Modeling the phase-contrast X-ray tomography imaging of medical samples. Math Models Comput Simul 4, 560–567 (2012). https://doi.org/10.1134/S2070048212060063
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S2070048212060063