Abstract
The Kuju fumaroles in central Kyushu, Japan began to erupt as phreatic in nature on 11 October 1995. To infer the thermal activity, main objectives were to monitor the radiative heat flux (RHF) before and after eruption of Kuju fumaroles in 1995 using 4 sets of Landsat TM thermal infrared data from 1990 to 1996; and to calculate and monitor the heat discharge rate (HDR) after multiplying RHF using a relationship coefficient between RHF and HDR, derived from two previous studies. The RHF was estimated by using the Stefan–Boltzmann equation for heat flow where we applied satellite image-derived spectral emissivity and land surface temperature. An increasing trend of total radiant heat flux was obtained of about 22–39 MW before the Kuju fumaroles eruption from 1990 to 1994 and a declining trend total RHF of about 37–11 MW after eruption from 1995 to 1996. RHF was strongly correlated with land surface temperature (LST) above ambient in our study. Spatial distribution of RHF also showed a similar trend of total RHF. After using this relationship coefficient, we obtained the HDR from our study area about 144.64, 249.74, 239.67 and 68.54 MW in 1990, 1994, 1995 and 1996, respectively. The HDR was much higher before eruption in October 11, 1995 than that of after the eruption in our study. Fumaroles area also showed an abrupt increase of bared land and no vegetation just after eruption within the thematic map in 1995. Statistics of LST and RHF also showed evidences of heat loss activity before and after eruption in 1995. In conclusion, we infer from this study that Landsat TM thermal infrared images are fully competent to monitor thermal activity from any active volcano fumaroles for future eruption.
Similar content being viewed by others
References
Ehara S (1992) Thermal structure beneath Kuju volcano, central Kyushu, Japan. J Volcanol Geotherm Res 54:107–115
Ehara S, Fujimitsu Y, Nishijima J, Fukuoka K, Ozawa M (2005) Change in the thermal state in a volcanic geothermal reservoir beneath an active fumarolic field after the 1995 phreatic eruption of Kuju volcano, Japan. In: Proceedings of the World geothermal congress 2005, Antalya, Turkey, 24–29 April 2005
Harris AJL, Lodato L, Dehn J, Spampinato L (2009) Thermal characterization of the Vulcano field. Bull Volcanol 71:441–458
Kamata H, Kobayashi T (1997) The eruptive rate and history of Kuju volcano in Japan during the past 15,000 years. J Volcanol Geotherm Res 76:163–171
Mia MB, Fujimitsu Y (2011) Study on satellite images based spectral emissivity, land surface temperature and land-cover in and around Kuju volcano, Central Kyushu, Japan. J Adv Sci Eng Res 1:177–191
Mia MB, Fujimitsu Y (2012) Mapping hydrothermal altered mineral deposits using Landsat 7 ETM+ image in and around Kuju volcano, Kyushu, Japan. J Earth Syst Sci 121(4):1049–1057
Mia MB, Fujimitsu Y (2013) Landsat thermal infrared based monitoring of heat losses from Kuju fumaroles area in Japan. Procedia Earth Planet Sci 6:114–120
Mia MB, Bromley CJ, Fujimitsu Y (2012a) Monitoring heat flux using Landsat TM/ETM+ thermal infrared data—a case study at Karapiti (‘Craters of the Moon’) thermal area, New Zealand. J Volcanol Geoth Res 235–236:1–10
Mia MB, Fujimitsu Y, Bromely C (2012b) Estimation and monitoring heat discharge rates using Landsat ETM+ thermal infrared data- a case study in Unzen geothermal field, Kyushu, Japan. In: Proceedings of SPIE Asia-Pacific Remote sensing Symposium 2012, Kyoto, Japan, 29 Oct–01 Nov 2012
Nakaboh M, Ono H, Sako M, Sudo Y, Hashimoto T, Hurst AW (2003) Continuing deflation by fumaroles at Kuju Volcano, Japan. Geophys Res Lett 30(7):1396
NASA (2009) Landsat 7 Science data users’ handbook
Qin Z, Karnieli A, Berliner P (2001) A mono-window algorithm for retrieving land surface temperature from Landsat TM data and its application to the Israel–Egypt border region. Int J Remote Sens 22(18):3719–3746
Savage SL, Lawrence RL, Custer SG, Jewett JT, Powell SL, Shaw JA (2010) Review of alternative methods for estimating terrestrial emittance and geothermal heat flux for Yellowstone National Park Using Landsat imagery. GISci Remote Sens 47(4):460–479
Valor E, Caselles V (1996) Mapping land surface emissivity from NDVI: application to European, African, and South American areas. Remote Sens Environ 57:167–184
Yamasaki T, Matsumoto Y, Hayashi M (1970) The geology and hydrothermal alterations of Otake geothermal area, Kujyo volcano group, Kyushu, Japan. Geothermics 2(Special issue 2):197–207
Acknowledgments
Authors would like to acknowledge their sincere gratitude to GCOE of Kyushu university financial support of this work. They also acknowledged USGS archive to provide satellite images with free of cost. The first author would also like to show his sincere gratefulness to Japan government (MEXT) PhD scholarship during this work.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mia, M.B., Nishijima, J. & Fujimitsu, Y. Monitoring heat flow before and after eruption of Kuju fumaroles in 1995 using Landsat TIR images. Acta Geod Geophys 50, 295–305 (2015). https://doi.org/10.1007/s40328-014-0075-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40328-014-0075-3