Experimental study on the inlet fogging system using two-fluid nozzles

  • Published:
Journal of Thermal Science Aims and scope Submit manuscript

Abstract

Large-capacity compressors in industrial plants and the compressors in gas turbine engines consume a considerable amount of power. The compression work is a strong function of the ambient air temperature. This increase in compression work presents a significant problem to utilities, generators and power producers when electric demands are high during the hot months. In many petrochemical process industries and gas turbine engines, the increase in compression work curtails plant output, demanding more electric power to drive the system. One way to counter this problem is to directly cool the inlet air. Inlet fogging is a popular means of cooling the inlet air to air compressors. In the present study, experiments have been performed to investigate the suitability of two-fluid nozzle for inlet fogging. Compressed air is used as the driving working gas for two-fluid nozzle and water at ambient conditions is dragged into the high-speed air jet, thus enabling the entrained water to be atomized in a very short distance from the exit of the two-fluid nozzle. The air supply pressure is varied between 2.0 and 5.0 bar and the water flow rate entrained is measured. The flow visualization and temperature and relative humidity measurements are carried out to specify the fogging characteristics of the two-fluid nozzle.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Meher-Homji, C. B. and Mee, T. R., “Gas turbine Power Augmentation by Fogging of Inlet Air”, Proceedings of 28 th Turbomachinery Symposium, Houston, Texas(1999)

  2. Parsons, R., ASHRAE Hand Book-Fundamentals, Chapter 6, Psychrometrics, ASHRAE Edition, Atlanta, Georgia (2001)

    Google Scholar 

  3. Ren, H. S., “Construction of a Generalized Psychrometric Chart for Different Pressures”, International Journal of Mechanical Engineering Education, 32/3, pp.212–222.

  4. Suryan, A, Kim, D. S., Lee, H. D., Kwon, J. K. and Kim, H. D., “Analytical Study on Evaporative Cooling Potential and Power Gains of Air Compressors by Inlet Fogging”, Proceedings of KSME Conference, pp.2637–2641, Pyeongchang, Korea, November, 2008.

  5. Suryan, A, Kim, D. S., Kim, B. J., and Kim, H. D., “Experimental Study on the Inlet Fogging System Using Two-fluid Nozzles”, Proceedings of KSME Conference, pp.275–278, Busan, Korea, May, 2009.

  6. Chaker, M, Meher-Homji, C. B. and Mee, T. R., “Inlet Fogging of Gas turbine Engines-Part A: Fog Droplet Thermodynamics, Heat Transfer and Practical Considerations”, Proceedings of ASME Turbo Expo 2002, 2002-GT-30562, Amsterdam.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Suryan, A., Kim, D.S. & Kim, H.D. Experimental study on the inlet fogging system using two-fluid nozzles. J. Therm. Sci. 19, 132–135 (2010). https://doi.org/10.1007/s11630-010-0132-3

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11630-010-0132-3

Keywords

Navigation