Life-threatening hemothorax resulting from right brachiocephalic vein perforation during right internal jugular vein catheterization

  • Clinical Report
  • Published:
Journal of Anesthesia Aims and scope Submit manuscript

Abstract

We present a life-threatening case of hemothorax resulting from right brachiocephalic vein perforation during right internal jugular vein catheterization. We considered that the guidewire had punctured the right brachiocephalic vein extraluminally and the catheter inserted over the guidewire had enlarged the size of the perforation. Despite the use of proper technique, an angle-tip guidewire may perforate the venous wall. Therefore, when there is negative aspiration after central venous catheterization, it is important to perform an emergency chest radiograph before proceeding with surgery; it is also important not to use an angle-tip guidewire.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Domino KB, Bowdle TA, Posner KL, Spitellie PH, Lee LA, Cheney FW. Injuries and liability related to central vascular catheters. A closed claims analysis. Anesthesiology. 2004;100:1411–1418.

    Article  PubMed  Google Scholar 

  2. Kulvatunyou N, Heard SO, Bankey PE. A subclavian artery injury, secondary to internal jugular vein cannulation, is a predictable right-sided phenomenon. Anesth Analg. 2002;95:564–566.

    Article  PubMed  Google Scholar 

  3. Jankovic Z, Boon A, Prasad R. Fatal haemothorax following largebore percutaneous cannulation before liver transplantation. Br J Anaesth. 2005;95:472–476.

    Article  PubMed  CAS  Google Scholar 

  4. Oropello JM, Leibowitz AB, Manasia A, Guidice RD, Benjamin E. Dilator-associated complications of central vein catheter insertion: possible mechanisms of injury and suggestions for prevention. J Cardiothorac Vasc Anesth. 1996;10:634–637.

    Article  PubMed  CAS  Google Scholar 

  5. Beilin Y, Bronheim D, Mandelbaum C. Hemothorax and subclavian artery laceration during “J” wire change of a right internal jugular vein catheter. Anesthesiology. 1998;88:1399–1400.

    Article  PubMed  CAS  Google Scholar 

  6. Powell H, Beechey APG. Internal jugular catheterization: case report of a potentially fatal hazard. Anaesthesia. 1990;45:458–459.

    Article  PubMed  CAS  Google Scholar 

  7. Jain U, Shah KB, Belusko RJ, Kumar P, Foy BK, Montoya A, Rao TL. Subclavian artery laceration and acute hemothorax on attempted internal jugular vein cannulation. J Cardiothorac Vasc Anesth. 1991;5:608–610.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

About this article

Cite this article

Innami, Y., Oyaizu, T., Ouchi, T. et al. Life-threatening hemothorax resulting from right brachiocephalic vein perforation during right internal jugular vein catheterization. J Anesth 23, 135–138 (2009). https://doi.org/10.1007/s00540-008-0696-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00540-008-0696-1

Key words

Navigation