Abstract
Purpose
The objective of this study was to evaluate the feasibility and safety of a minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure for proximal humeral shaft fractures using lateral minimal proximal and distal approaches and lateral bridge plating with primary radial nerve control, and to assess its clinical and radiographic outcomes.
Methods
A retrospective review was done for the medical records of adult patients admitted for fracture of the proximal humeral shaft without associated injury to the ipsilateral upper limb and who consented to undergo a novel MIPPO technique herein reported. Patients were reviewed at regular follow-up periods and assessed at a final follow-up for evaluation of Constant, normalized Constant, and QuickDASH scores.
Results
There were 21 adult patients with mean age of 56 years. Three patients were lost from early follow-up; one of them had post-operative radial nerve paralysis. Eighteen patients were reviewed for the purpose of this study at a mean of 20 months of final follow-up; among them, one patient developed post-operative radial nerve paralysis with complete recovery after three months. Bone healing was achieved without any malalignment in 17 patients at a mean of 15 weeks, and one patient developed nonunion. At final assessment (mean, 20 months), the mean values of Constant, normalized Constant, and QuickDASH scores were 84 (range, 59 to 100), 95 (range, 73 to 100), and 5 (range, 0 to 18.2) respectively.
Conclusion
Compared to pre-reported methods of MIPPO, this technique of lateral proximal and distal mini-approaches with lateral bridge plating after primary control of the radial nerve seems safe and feasible for proximal humeral shaft fractures. It gives good clinical and radiographic results with excellent restoration of upper limb function, very low incidence of post-operative radial nerve injury, and high rate of bone union in good alignment.
Similar content being viewed by others
References
Heitemeyer U, Kemper F, Hierholzer G, Haines J (1987) Severely comminuted femoral shaft fracture: treatment by bridging plate osteosynthesis. Arch Orthop Trauma Surg 106:327–330
Helfet DL, Shonnard PY, Levine D, Borrelli J Jr (1997) Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury 28(Suppl 1):42–48
Livani B, Belangero WD (2004) Bridging plate osteosynthesis of humeral shaft fractures. Injury 35:587–595
Apivatthakakul T, Arpornchayanona O, Bavornratanavech S (2005) Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture: is it possible? A cadaveric study and preliminary report. Injury 36:530–538
Ji F, Tong D, Tang H, Cai X, Zhang Q, Li J, Wang Q (2009) Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach. Int Orthop 33:543–547. https://doi.org/10.1007/s00264-008-0522-2
Lau TW, Leung F, Chan CF, Chow SP (2007) Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture. Int Orthop 31:657–664. https://doi.org/10.1007/s00264-006-0242-4
Rancan M, Dietrich M, Lamdark T, Can U, Platz A (2010) Minimal invasive long PHILOS-plate osteosynthesis in metadiaphyseal fractures of the proximal humerus. Injury 41:1277–1283
Kellam JF, Meinberg EG, Agel J, Karam MD, Roberts CS (2018) Fracture and dislocation classification compendium-2018. International Comprehensive Classification of Fractures and Dislocations Committee. J Orthop Trauma 32(Supp 1):S15–S16. https://doi.org/10.1097/BOT.0000000000001063
Katolik LI, Romeo AA, Cole BJ, Verma NN, Hayden JK, Bach BR (2005) Normalization of the Constant score. J Shoulder Elb Surg 14:279–285. https://doi.org/10.1016/j.jse.2004.10.009
Beaton DE, Wright JG, Katz JN (2005) Development of the QuickDASH: comparison of three item-reduction approaches. J Bone Joint Surg Am 87:1038–1046. https://doi.org/10.2106/JBJS.D.02060
Gardner MJ, Griffith MH, Dines JS, Lorich DG (2004) A minimally invasive approach for plate fixation of the proximal humerus. Bull Hosp Jt Dis 62:18–23
Denies E, Nijs S, Sermon A, Broos P (2010) Operative treatment of humeral shaft fractures. Comparison of plating and intramedullary nailing. Acta Orthop Belg 76:735–742
Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg (Br) 84-B:1093–1110
Fernández Dell’Oca AA (2002) The principle of helical implants: unusual ideas worth considering. Injury 33(Supp 1):1–40
Krishna KR, Sridhar I, Ghista DN (2008) Analysis of the helical plate for bone fracture fixation. Injury 39:1421–1436
Tan JCH, Kagda FHY, Murphy D, Thambiah JS, Khong KS (2012) Minimally invasive helical plating for shaft of humerus fractures: technique and outcome. Open Orthop J 6:184–188
Apivatthakakul T, Patiyasikan S, Luevitoonvechkit S (2010) Danger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: a cadaveric study. Injury 41:169–172
Livani B, Belangero WD, Andrade K, Zuiani G, Pratali R (2009) Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation. Int Orthop 33:1719–1723. https://doi.org/10.1007/s00264-008-0616-x
Kobayashi M, Watanabe Y, Matsushita T (2010) Early full range of shoulder and elbow motion is possible after minimally invasive plate osteosynthesis for humeral shaft fractures. J Orthop Trauma 24:212–216
An Z, Zeng B, He X, Chen Q, Hu S (2010) Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique. Int Orthop 34:131–135
Oh CW, Byun YS, Oh JK, Kim JJ, Jeon IH, Lee JH, Park KH (2012) Plating of humeral shaft fractures: comparison of standard conventional plating versus minimally invasive plating. Orthop Traumatol Surg Res 98:54–60
Lee T, Yoon J (2016) Newly designed minimally invasive plating of a humerus shaft fracture; a different introduction of the plate. Int Orthop 40:2597–2602
Benninger E, Meier C (2017) Minimally invasive lateral plate placement for metadiaphyseal fractures of the humerus and its implications for the distal deltoid insertion- it is not only about the radial nerve. A cadaveric study. Injury 48:615–620
Livani B, Belangero WD, Castro de Medeiros R (2006) Fractures of the distal third of the humerus with palsy of the radial nerve. Management using minimally invasive percutaneous plate osteosynthesis. J Bone Joint Surg (Br) 88-B:1625–1628. https://doi.org/10.1302/0301-620X.88B12.17924
Zhao W, Qu W, Fu C, Jiang H, Liu S, Cheng C (2017) Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus. Int Orthop 41:1757–1762. https://doi.org/10.1007/s00264-017-3514-2
Chamseddine AH, Abdallah A, Zein H, Taha A (2017) Transfracture medial transposition of the radial nerve associated with plate fixation of the humerus. Int Orthop 41:1463–1470. https://doi.org/10.1007/s00264-016-3397-7
Chamseddine AH, Zein HK, Alasiry AA, Mansour NA, Bazzal AM (2013) Trans-fracture transposition of the radial nerve during the open approach of humeral shaft fractures. Eur J Orthop Surg Traumatol 23:725–730. https://doi.org/10.1007/s00590-012-1065-1
Ahmed AF, Parambathkandi AM, Kong WJG, Salameh M, Mudawi A, Abousamhadaneh M, Abuodeh Y, Ahmed GO (2020) The role of ulnar nerve subcutaneous anterior transposition during open reduction and internal fixation of distal humerus fractures: a retrospective cohort study. Int Orthop. Published online 03 October 2020. https://doi.org/10.1007/s00264-020-04745-0
Allende C, Vanoli F, Gentile L, Gutierrez N (2018) Minimally invasive plate osteosynthesis in humerus nonunion after intramedullary nailing. Int Orthop 42:2685–2689. https://doi.org/10.1007/s00264-018-3911-1
Brunner A, Thormann S, Babst R (2012) Minimally invasive percutaneous plating of proximal humeral shaft fractures with the proximal humerus internal locking system (PHILOS). J Shoulder Elb Surg 21:1056–1063. https://doi.org/10.1016/j.jse.2011.05.016
Lee HJ, Oh CW, Oh JK, Apivatthakakul T, Kim JW, Yoon JP, Lee DJ, Jung JW (2013) Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator. Arch Orthop Trauma Surg 133:649–657
Kamara A, Ji X, Liu T, Zhan Y, Li J, Wang E (2019) A comparative biomechanical study on different fixation techniques in the management of transverse metaphyseal-diaphyseal junction fractures of the distal humerus in children. Int Orthop 43:411–416. https://doi.org/10.1007/s00264-018-3968-x
Zogaib RK, Morgan S, Belangero PS, Fernandes HJA, Belangero WD, Livani B (2014) Minimal invasive osteosynthesis for treatment of diaphyseal transverse humeral shaft fractures. Acta Ortop Bras 22:94–98. http://www.scielo.br/aob
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Chamseddine, A.H., El-Hajj, O.M., Haidar, I.M. et al. Minimally invasive percutaneous plate osteosynthesis for treatment of proximal humeral shaft fractures. International Orthopaedics (SICOT) 45, 253–263 (2021). https://doi.org/10.1007/s00264-020-04858-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-020-04858-6