Skip to main content
Log in

On-line fermenter headspace gas analysis of methanol and ethanol by capillary inlet mass spectrometry

  • Published:
Biotechnology Techniques

Summary

A new capillary inlet system was used with a magnetic sector mass spectrometer to analyse headspace gas from air-sparged aqueous solutions of methanol and ethanol. The system responded to pulse additions within 2 minutes and gave ≥90% of equilibrium response after 10 minutes. No memory effects or hysteresis were observed. Signal to concentration ratio was linear with alcohol concentrations up to 5 g/L. Liquid ethanol concentration in aerobic yeast fermentation was followed successfully by on-line headspace gas analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bohatka, S., Langer, G., Szilagyi, J. and Berecz, I. (1983). Int. J. Mass. Spectrom. Ion. Phys.,48, 277–280.

    Article  Google Scholar 

  • buckland, B.C., Brix, T., Fastert, H., Gbewonyo, K., Hunt, G. and Jain, D. (1985). Bio/Technology,3, 982–988.

    Article  Google Scholar 

  • Cregg, J.M., Tschopp, J.F., Stillman, C., Siegel, R., Akong, M., Craig, W.S., Buckholz, R.G., Madden, K.R., Kellaris, P.A., Davis, G.R., Smiley, B.L., Cruze, J., Torregrossa, R., veliçelibi, G. and Thill, G.P. (1987). Bio/Technology,5, 479–485.

    Article  Google Scholar 

  • Hamer, G. (1965a). Biotechnol. Bioeng.,7, 199–214.

    Article  Google Scholar 

  • Hamer, G. (1965b). Biotechnol. Bioeng.,7, 215–227.

    Article  Google Scholar 

  • Heinzle, E. (1987). “Mass Spectrometry for On-line Monitoring of Biochemical Processes”, in Advances in Biochemical Engineering/Biotechnology,35, 1–45.

  • Heinzle, E., Furukawa, K., Dunn, I.J. and Bourne, J.R. (1983). Bio/Technology,1, 181–188.

    Article  Google Scholar 

  • Lloyd, D. and James, C.J. (1987). FEMS Microbiol. Letts.42, 27–31.

    Article  Google Scholar 

  • Pungor, E., Perley, C.R., Cooney, C.L. and Weaver, J.C. (1983). Biotechnol. Letts.,2, 409–414.

    Article  Google Scholar 

  • Pungor, E., Schaefer, E.J., Cooney, C.L. and Weaver, J.C. (1983). Eur. J. Appl. Microbiol. Biotechnol.18, 135–140.

    Article  Google Scholar 

  • Williams, L.A. (1983). Biotechnol. Bioeng.,25, 1597–1612.

    Article  Google Scholar 

  • Winter, M.J. (1987). “The application of single detector magnetic sector mass spectrometer systems in fermentation off-gas and liquid analysis”, in Mass Spectrometry in Biotechnological Process Analysis and Control, Eds. Heinzle, E. and Reuss, M., Plenum Press, New York, 17–38.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Camelbeeck, J.P., Comberbach, D.M., Goossens, J. et al. On-line fermenter headspace gas analysis of methanol and ethanol by capillary inlet mass spectrometry. Biotechnol Tech 2, 183–188 (1988). https://doi.org/10.1007/BF01875762

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01875762

Keywords

Navigation