Abstract
Activated C is a useful medium for simultaneous sampling of trace gases. However, preferential canals in the C cartridge and water vapor condensation should be avoided. The most critical component is metallic Hg. Based on the principle of permeation, a Hg calibration gas was prepaired with a concentration range between 4 and 300 μg·m−3. The collection efficiency of Hgo on activated C as a function of temperature and flow was studied. It appeared that the residence time (flow) and temperature should be carefully chosen. The collection efficiency decreases at increasing temperature and increasing flow. Hg adsorption in tubes, plane filters, in-depth filters and thimble filters was also investigated. Based on the results obtained a sampling train is made for sampling flue gases. The same train can also be used for sampling ambient air.
Similar content being viewed by others
References
Bergström, J.G.T.: 1986, Waste management & Research 4, 57.
Coulson, J.:1973, Survey of manual methodes of measurements of asbestos, beryllium, lead, cadmium, selenium and mercury in stationary source emissions, EPA Report EPA-650/4-74-015.
Dumary, R., Heindryckx, R. and Dams, R.: 1981, Environmental Sc. & Techn. 15, 206.
Hall, B., Schager, P. and Lindqvist, O.:1991, Water, Air and Soil pollut., in press.
Kaakinen, J.W., Jorden, R.M., Lawasani, M.H. and West, R.E.:1975, Environmental Sc. & Techn. 9, 862.
Krivan, V. and Haas, H.F.: 1988, Fresenius Z. Anal. Chem. 332, 1.
Larjava, K., Reith, J. and Klockow, D.: 1990, Intern. J. Environ. Anal. Chem. 38, 31.
Matsumura, Y.: 1974, Atmospheric Environment 8, 1321.
Meij, R. and Sprong, J.: 1982, Kwikbepaling in de rookgassen van kolengestookte eenheden. Laboratorium- en praktijkexperimenten, KEMA memorandum 82-39 MOL.
Meij, R., Spoelstra, H. and Waard, F.J. de: 1989, The determination of gaseous inorganic trace compounds in flue gases from coal fired power plants, in: Proceedings of the 8th World Clean Air Congress vol III 717..722, held at Den Haag, The Netherlands, September 1989.
Meij, R.: 1991, Water, Air and Soil pollut., in press.
Metzger, M. and Braun, H.: 1987, Chemosphere 16, 821
Schroeder, W.H. and Jackson, R.A.: 1985, Intern. J. Environ. Anal. Chem. 22, 1.
Shendikar, A.D., Dample A. and Gutknecht, W .F.: 1984, Collection efficiency evaluation of Hg-trapping media for the SASS train impinger system, report of Research Triangle Institute, no. EPA-600/7-84-089
Starkovich, J.A., Maddalone, R.F., Kraft, M.L., Zee, C.A., Lin, C. and Flegal, C.A.: 1976, Measurement techniques for inorganic trace materials in control system streams, EPA report EPA 600/2-76-283.
Xia, Z. and Munthe, J.: 1991, Water, Air and Soil pollut., in press.