Abstract
Because of the variable durability of pacemaker systems characteristically present since their initial use, methods of post-implant observation have been required to reduce the incidence of sudden and unpredicted failure of the implanted system and maximize the useful longevity of other units.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
D.P. Morse, U.F. Tesler and G.M. Lemole, “The actual lifespan of pacemakers”, Chest 64 (4), 454–458 (1973)
V. Parsonnet, L. Gilbert and I.R. Zucker, “Natural history of pacemaker wires”, J. Thor. Cardiovasc. Surg. 65, 315 (1973)
J.W. Van Den Berg, F. A. Rodrigo, H.J.Th. Thalen, et al, “Photoanalysis of the condition of implanted pacemaker and electrode circuits”, Proc. Kon. Nedrl. Akad. Wet. (Biol. Med.) 70, 419 (1967)
V. Parsonnet, G.H. Meyers, L. Gilbert, et al, “Prediction of impending pacemaker failure in a pacemaker clinic”, Amer. J. Cardiol. 25, 311 (1970)
D.J.W. Escher and S. Furman, “Oscilloscopic and recent other methods of implantable pacemaker follow-up”, Ann. Cardiol. Angeiol. 20, 503 (1971)
S. Furman, B. Parker and D.J.W. Escher, “Transtelephone pacemaker clinic”, J. Thor. Cardiovasc. Surg. 61, 827 (1971)
S. Furman, “Transtelephone observation of implanted cardiac pacemakers”, Med. lnstrum. 7, 196–202 (1973)
R.S. Pennock, L.S. Dreifus, D.P. Morse, et al, “Cardiac pacemaker function”, J. Amer. Med. Assn. 222, 1379 (1972)
S. Ruben, “Sealed zinc-mercury oxide cells for implantable cardiac pacemakers”, Ann. N.Y. Acad. Sci. 167, 627 (1969)
D.J.W. Escher, H. Hochberg, E. King, et al, “Pacemaker electronic follow-up: complete unique system”, Circulation — in press
M. Bilitch, E.E. Cassady and J.S. Llyod, “Physician follow-up of patients with permanent cardiac pacemakers”, H.J.Th. Thalen, ed. Van Gorcum & Comp. B. V. Assen — the Netherlands, 1973, p. 443
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1975 Springer-Verlag Berlin-Heidelberg
About this chapter
Cite this chapter
Furman, S., Escher, D.J.W. (1975). Transtelephone Pacemaker Monitoring. In: Schaldach, M., Furman, S. (eds) Engineering in Medicine. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-66187-7_12
Download citation
DOI: https://doi.org/10.1007/978-3-642-66187-7_12
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-66189-1
Online ISBN: 978-3-642-66187-7
eBook Packages: Springer Book Archive