Skip to main content

A Bayesian Framework for Estimating Respiratory Liver Motion from Sparse Measurements

  • Conference paper
Abdominal Imaging. Computational and Clinical Applications (ABD-MICCAI 2011)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 7029))

Abstract

In this paper, we present an approach for modelling and predicting organ motion from partial information. We used 4D-MRI sequences of 12 subjects to build a statistical population model for respiratory motion of the liver. Using a Bayesian reconstruction approach, a pre-operative CT scan and a few known surrogate markers, we are able to accurately predict the position of the entire liver at all times. The surrogates may, for example, come from ultrasound, portal images captured during radiotherapy or from implanted electromagnetic beacons. In leave-one-out experiments, we achieve an average prediction error of 1.2 mm over sequences of 20 min with only three surrogates. Our model is accurate enough for clinically relevant treatment intervals and has the potential to be used for adapting the gating window in tumour therapy or even for tracking a tumour continuously during irradiation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 54.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 69.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Barber, C.B., Dobkin, D.P., Huhdanpaa, H.: The quickhull algorithm for convex hulls. ACM T. Math. Software 22(4), 469–483 (1996)

    Article  MathSciNet  MATH  Google Scholar 

  2. Blanz, V., Vetter, T.: Reconstructing the complete 3D shape of faces from partial information. Informationstechnik und Technische Informatik 44(6), 295–302 (2002)

    Google Scholar 

  3. Ehrhardt, J., Werner, R., Schmidt-Richberg, A., Handels, H.: Statistical modeling of 4d respiratory lung motion using diffeomorphic image registration. IEEE Transactions on Medical Imaging 30(2), 251–265 (2011)

    Article  Google Scholar 

  4. He, T., Xue, Z., Xie, W., Wong, S.T.C.: Online 4-D CT Estimation for Patient-Specific Respiratory Motion Based on Real-Time Breathing Signals. In: Jiang, T., Navab, N., Pluim, J.P.W., Viergever, M.A. (eds.) MICCAI 2010 Part III. LNCS, vol. 6363, pp. 392–399. Springer, Heidelberg (2010)

    Chapter  Google Scholar 

  5. Rohlfing, T., Maurer Jr., C.R., O’Dell, W.G., Zhong, J.: Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images. Med. Phys. 31(3), 427–432 (2004)

    Article  Google Scholar 

  6. Rueckert, D., Sonoda, L.I., Hayes, C., Hill, D.L.G., Leach, M.O., Hawkes, D.J.: Nonrigid registration using free-form deformations: application to breast MR images. IEEE T. Med. Imag. 18(8), 712–721 (1999)

    Article  Google Scholar 

  7. Shirato, H., Seppenwoolde, Y., Kitamura, K., Onimura, R., Shimizu, S.: Intrafractional tumor motion: lung and liver. Semin. Radiat. Oncol. 14(1), 10–18 (2004)

    Article  Google Scholar 

  8. von Siebenthal, M., Cattin, P.C., Gamper, U., Lomax, A., Székely, G.: 4D MR Imaging Using Internal Respiratory Gating. In: Duncan, J.S., Gerig, G. (eds.) MICCAI 2005. LNCS, vol. 3750, pp. 336–343. Springer, Heidelberg (2005)

    Chapter  Google Scholar 

  9. von Siebenthal, M., Székely, G., Lomax, A., Cattin, P.: Inter-Subject Modelling of Liver Deformation During Radiation Therapy. In: Ayache, N., Ourselin, S., Maeder, A. (eds.) MICCAI 2007, Part I. LNCS, vol. 4791, pp. 659–666. Springer, Heidelberg (2007)

    Chapter  Google Scholar 

  10. von Siebenthal, M., Székely, G., Lomax, A., Cattin, P.: Systematic errors in respiratory gating due to intrafraction deformations of the liver. Med. Phys. 34(9), 3620–3629 (2007)

    Article  Google Scholar 

  11. Zsemlye, G.: Shape Prediction from Partial Information. Ph.D. thesis, ETH Zurich (2005)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Preiswerk, F., Arnold, P., Fasel, B., Cattin, P.C. (2012). A Bayesian Framework for Estimating Respiratory Liver Motion from Sparse Measurements. In: Yoshida, H., Sakas, G., Linguraru, M.G. (eds) Abdominal Imaging. Computational and Clinical Applications. ABD-MICCAI 2011. Lecture Notes in Computer Science, vol 7029. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-28557-8_26

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-28557-8_26

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-28556-1

  • Online ISBN: 978-3-642-28557-8

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics