Skip to main content
  • 2948 Accesses

Abstract

Balance of plant systems in nuclear plants, such as service water systems, are a critical part of the facility’s infrastructure. System integrity and performance are vital for plant reliability and essential to achieving a plant life of 40 years and beyond. The low temperature and pressure service water piping systems are primarily degraded by corrosion in untreated waters. Corrosion allowances, based upon very simplistic considerations of general corrosion in untreated raw water, were a part of the original design. However, long term service in many such systems has shown that localized corrosion phenomena, from microbiologically influenced corrosion (MIC), pitting, and underdeposit effects, have compromised system integrity. Because of the complexity and random nature of corrosion processes, it is nearly impossible to develop a mathematically deterministic model (like the typically used corrosion allowances) that accurately predicts pipe wall loss. However, when statistical distributions are used to describe the various corrosion processes, mathematical algorithms that incorporate all of the distributions, iterated a statistically significant number of times, can be used to forecast the most probable number of leaks. This approach was used to predict the condition of service water piping at a US Nuclear Power Plant, comparing results to service experience and inspection results. The results were ultimately used by the plant for targeting inspections and for long term planning of replacements and replacement schedules.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 319.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. G.J. Licina, S.W. Borenstein, “Replacing, Refurbishing Nuclear Service Water Piping,” Power, December 1993.

    Google Scholar 

  2. “Service Water System Problems Affecting Safety-Related Equipment,” Generic Letter 89–13, 7–18–89

    Google Scholar 

  3. R.A. Pisigan and J.E. Singley, “Evaluation of water corrosivity using the Langelier index and relative corrosion models,” NACE, 1985.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 TMS (The Minerals, Metals & Materials Society)

About this paper

Cite this paper

Licina, G., Dedhia, D. (2011). Balance of Plant Corrosion Issues in Aging Nuclear Power Plants. In: Busby, J.T., Ilevbare, G., Andresen, P.L. (eds) Proceedings of the 15th International Conference on Environmental Degradation of Materials in Nuclear Power Systems — Water Reactors. Springer, Cham. https://doi.org/10.1007/978-3-319-48760-1_62

Download citation

Publish with us

Policies and ethics