Skip to main content

Role of Computed Tomography in Transcatheter Aortic Valve Implantation

  • Chapter
Transcatheter Aortic Valve Implantation
  • 1400 Accesses

Abstract

Computed tomography (CT) has emerged as the standard of care for preprocedural planning of transcatheter aortic valve implantation (TAVI). Because of the submillimeter isotropic 3D imaging capability and the unique ability of imaging calcification and vessel tortuosity in 3D, multi-detector row CT imaging has been routinely used in clinic to perform patient screening, annulus sizing, transcatheter heart valve selection, and access route evaluation before the TAVI procedure. CT-based annular sizing has been shown to be superior to 2D echocardiography in predicting the occurrence of paravalvular leak post TAVI. In this chapter, we reviewed the role of CT imaging in TAVI using the most commonly used self-expandable and balloon-expandable TAVI valves as examples and discussed the CT acquisition protocols and the image processing and evaluation techniques of the CT images. Specifically, we gave detailed descriptions of a number of important CT analysis techniques for the purpose of preprocedural planning, including the measurement of the aortic annulus and the aortic root, the characterization of calcification, the calculation of the angiographic projection angles, and the assessment of the access route. The utility of CT post TAVI was also discussed.

Part of the work was done at Piedmont Heart Institute, Atlanta, GA, USA

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Blanke P, Schoepf UJ, Leipsic JA. CT in transcatheter aortic valve replacement. Radiology. 2013;269(3):650–69.

    PubMed  Google Scholar 

  2. Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, et al. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol. 2012;59(14):1275–86.

    PubMed  Google Scholar 

  3. Schultz CJ, Tzikas A, Moelker A, Rossi A, Nuis R-J, Geleijnse MM, et al. Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis. Catheter Cardiovasc Interv. 2011;78(3):446–55.

    PubMed  Google Scholar 

  4. Gurvitch R, Webb JG, Yuan R, Johnson M, Hague C, Willson AB, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2011;4(11):1235–45.

    PubMed  Google Scholar 

  5. Ng ACT, Delgado V, van der Kley F, Shanks M, van de Veire NRL, Bertini M, et al. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging. 2010;3(1):94–102.

    PubMed  Google Scholar 

  6. Hayashida K, Lefèvre T, Chevalier B, Hovasse T, Romano M, Garot P, et al. Transfemoral aortic valve implantation new criteria to predict vascular complications. JACC Cardiovasc Interv. 2011;4(8):851–8.

    PubMed  Google Scholar 

  7. Felmly LM, De Cecco CN, Schoepf UJ, Varga-Szemes A, Mangold S, McQuiston AD, et al. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning. Eur Radiol. 2017;27(5):1944–53.

    PubMed  Google Scholar 

  8. Yuan R, Shuman WP, Earls JP, Hague CJ, Mumtaz HA, Scott-Moncrieff A, et al. Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography—a prospective randomized trial. Radiology. 2012;262(1):290–7.

    PubMed  Google Scholar 

  9. Schoenhagen P, Kapadia SR, Halliburton SS, Svensson LG, Murat Tuzcu E. Computed tomography evaluation for transcatheter aortic valve implantation (TAVI): imaging of the aortic root and iliac arteries. J Cardiovasc Comput Tomogr. 2011;5(5):293–300.

    PubMed  Google Scholar 

  10. Willson AB, Webb JG, Labounty TM, Achenbach S, Moss R, Wheeler M, et al. 3-Dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am Coll Cardiol. 2012;59(14):1287–94.

    PubMed  Google Scholar 

  11. Binder RK, Webb JG, Willson AB, Urena M, Hansson NC, Norgaard BL, et al. The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial. J Am Coll Cardiol. 2013;62(5):431–8.

    PubMed  Google Scholar 

  12. Willson AB, Webb JG, Freeman M, Wood DA, Gurvitch R, Thompson CR, et al. Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: comparison with transesophageal echocardiography and rationale for implementation in a prospective trial. J Cardiovasc Comput Tomogr. 2012;6(6):406–14.

    PubMed  Google Scholar 

  13. Schultz CJ, Moelker A, Piazza N, Tzikas A, Otten A, Nuis RJ, et al. Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer’s guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J. 2010;31(7):849–56.

    PubMed  Google Scholar 

  14. Webb JG, Chandavimol M, Thompson CR, Ricci DR, Carere RG, Munt BI, et al. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation. 2006;113(6):842–50.

    PubMed  Google Scholar 

  15. Delgado V, Ng ACT, van de Veire NR, van der Kley F, Schuijf JD, Tops LF, et al. Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function. Eur Heart J. 2010;31(9):1114–23.

    PubMed  Google Scholar 

  16. Koos R, Mahnken AH, Dohmen G, Brehmer K, Günther RW, Autschbach R, et al. Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int J Cardiol. 2011;150(2):142–5.

    PubMed  Google Scholar 

  17. John D, Buellesfeld L, Yuecel S, Mueller R, Latsios G, Beucher H, et al. Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv. 2010;3(2):233–43.

    PubMed  Google Scholar 

  18. Herrmann HC, Thourani VH, Kodali SK, Makkar RR, Szeto WY, Anwaruddin S, et al. One-year clinical outcomes with SAPIEN 3 transcatheter aortic valve replacement in high-risk and inoperable patients with severe aortic stenosis. Circulation. 2016;134(2):130–40.

    PubMed  Google Scholar 

  19. Forrest JK, Mangi AA, Popma JJ, Khabbaz K, Reardon MJ, Kleiman NS, et al. Early outcomes with the Evolut PRO repositionable self-expanding transcatheter aortic valve with pericardial wrap. JACC Cardiovasc Interv. 2018;11(2):160–8.

    PubMed  Google Scholar 

  20. Mauri V, Reimann A, Stern D, Scherner M, Kuhn E, Rudolph V, et al. Predictors of permanent pacemaker implantation after transcatheter aortic valve replacement with the SAPIEN 3. JACC Cardiovasc Interv. 2016;9(21):2200–9.

    PubMed  Google Scholar 

  21. Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M, Detrano R. Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol. 1990;15(4):827–32.

    CAS  PubMed  Google Scholar 

  22. Callister TQ, Cooil B, Raya SP, Lippolis NJ, Russo DJ, Raggi P. Coronary artery disease: improved reproducibility of calcium scoring with an electron-beam CT volumetric method. Radiology. 1998;208(3):807–14.

    CAS  PubMed  Google Scholar 

  23. Hong C, Becker CR, Joseph Schoepf U, Ohnesorge B, Bruening R, Reiser MF. Coronary artery calcium: absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies. Radiology. 2002;223(2):474–80.

    PubMed  Google Scholar 

  24. Schultz C, Rossi A, van Mieghem N, van der Boon R, Papadopoulou S-L, van Domburg R, et al. Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis. EuroIntervention. 2011;7(5):564–72.

    PubMed  Google Scholar 

  25. Kurra V, Kapadia SR, Tuzcu EM, Halliburton SS, Svensson L, Roselli EE, et al. Pre-procedural imaging of aortic root orientation and dimensions: comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography. JACC Cardiovasc Interv. 2010;3(1):105–13.

    PubMed  Google Scholar 

  26. Gurvitch R, Wood DA, Leipsic J, Tay E, Johnson M, Ye J, et al. Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2010;3(11):1157–65.

    PubMed  Google Scholar 

  27. Binder RK, Leipsic J, Wood D, Moore T, Toggweiler S, Willson A, et al. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography. Circ Cardiovasc Interv. 2012;5(2):247–52.

    PubMed  Google Scholar 

  28. Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. Eur Heart J. 2012;33(19):2403–18.

    PubMed  Google Scholar 

  29. Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA. SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr. 2012;6(6):366–80.

    PubMed  Google Scholar 

  30. Leipsic J, Hague CJ, Gurvitch R, Ajlan AM, Labounty TM, Min JK. MDCT to guide transcatheter aortic valve replacement and mitral valve repair. Cardiol Clin. 2012;30(1):147–60.

    PubMed  Google Scholar 

  31. Masson J-B, Kovac J, Schuler G, Ye J, Cheung A, Kapadia S, et al. Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications. JACC Cardiovasc Interv. 2009;2(9):811–20.

    PubMed  Google Scholar 

  32. Tay ELW, Gurvitch R, Wijeysinghe N, Nietlispach F, Leipsic J, Wood DA, et al. Outcome of patients after transcatheter aortic valve embolization. JACC Cardiovasc Interv. 2011;4(2):228–34.

    PubMed  Google Scholar 

  33. Chakravarty T, Søndergaard L, Friedman J, De Backer O, Berman D, Kofoed KF, et al. Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study. Lancet. 2017;389(10087):2383–92.

    PubMed  Google Scholar 

  34. Pislaru SV, Nkomo VT, Sandhu GS. Assessment of prosthetic valve function after TAVR. JACC Cardiovasc Imaging. 2016;9(2):193–206.

    PubMed  Google Scholar 

  35. Jilaihawi H, Asch FM, Manasse E, Ruiz CE, Jelnin V, Kashif M, et al. Systematic CT methodology for the evaluation of subclinical leaflet thrombosis. JACC Cardiovasc Imaging. 2017;10(4):461–70.

    PubMed  Google Scholar 

  36. Moat NE. Will TAVR become the predominant method for treating severe aortic stenosis? N Engl J Med. 2016;374(17):1682–3.

    CAS  PubMed  Google Scholar 

Download references

Acknowledgments

Conflict of Interest: None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Zhen Qian .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this chapter

Cite this chapter

Qian, Z. (2019). Role of Computed Tomography in Transcatheter Aortic Valve Implantation. In: Giordano, A., Biondi-Zoccai, G., Frati, G. (eds) Transcatheter Aortic Valve Implantation. Springer, Cham. https://doi.org/10.1007/978-3-030-05912-5_8

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-05912-5_8

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-05911-8

  • Online ISBN: 978-3-030-05912-5

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics