Abstract
High frequency Stirling type pulse tube cryocoolers offer significant advantages in efficiency, size and reliability, over conventional Stirling coolers or low frequency GM type pulse tube refrigerators. This kind of cooler has potential application for HTS motors and generators. A baseline single stage Stirling type pulse tube cooler has been designed and constructed based on a thermodynamic model. An oil-free, linear motor driven compressor is used. The cooler has been tested for its cooldown and cooling capacity, with heat rejected by chilled water at 290 K. Initial testing indicates that the cooler can reach the best no load temperature of 37 K within 30 minutes and has a cooling capacity of about 50 W at 55 K and 140 watts at 80 K with an input power of 3.4 kW. 11% Carnot efficiency has been reached at 80 K. The dependency of cooler performance on pulse tube orientation and input power has been investigated. In addition, matching issues between cooler and compressor, and flow distribution issues within the pulse tube and regenerator, are discussed in the paper.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Verebelyi, D.T., Schoop, U. et al., “Uniform Performance of Continuously Processed MOD-YBCO-coated Conductor Using a Textured Ni-W Substrate,” Superconductivity Science & Technology, vol. 16 (2003), pp. L19–L22.
Martin, J.L. “Pulse Tube Cryocoolers for Industrial Applications,” Advances in Cryogenic Engineering, 47A, American Institute of Physics, Melville, NY (2002), pp. 662–669.
Thummes, G., Schreiber, M., Landgraf, R. and Heiden, C, “Convective Heat Losses in Pulse Tube Coolers: Effect of Pulse Tube Inclination,” Cryocoolers 9, Kluwer Academic/Plenum Publishers, New York (1997), pp. 393–402.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2005 Springer Science+Business Media, Inc.
About this paper
Cite this paper
Yuan, J., Maguire, J. (2005). Development of a Single Stage Pulse Tube Refrigerator with Linear Compressor. In: Ross, R.G. (eds) Cryocoolers 13. Springer, Boston, MA. https://doi.org/10.1007/0-387-27533-9_22
Download citation
DOI: https://doi.org/10.1007/0-387-27533-9_22
Publisher Name: Springer, Boston, MA
Print ISBN: 978-0-387-23901-9
Online ISBN: 978-0-387-27533-8
eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)