Bell prover — calibration and monitoring of time stability

  • Original Article
  • Published:
MAPAN Aims and scope Submit manuscript

Abstract

This paper is focused on the calibration and measurement of the geometric parameters of a bell prover that serves as a standard of volume of gas flow. It also includes methods for monitoring the time stability of the bell prover: intra- and inter-laboratory comparison measurements, Shewhart analysis and planned evaluation of recalibration intervals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Š. Makovník and I. Mikulecký, Primárny etalón prietoku a prete eného objemu plynu SMU (in slovak) (Primary Standard of Gas Flow of SMU). Metrológia a skúšbníctvo, 9 (2004) 25–34.

    Google Scholar 

  2. Primary Standard of Flow and of Delivered Volume of Gas, In: Centre of Flow of SMU, Bulletin for Euromet TC Flow Meeting, Bratislava, (2004). http://230.smu.sk/storage/root/pdf/Bulletin%20Slovak%20Institute%20of%20Metrology.pdf

  3. Calibration and Measurement Capabilities (CMC), Mass and Related Quantities — Gas Flow, Slovakia, SMU. http://kcdb.bipm.org/appendixC/country_list_search.asp?CountSelected=SK&sservice=M/FF.9.2

  4. S. Makovník, Národny etalón prietoku a prete eného objemu plynu: Súhrnná správa o etalóne. (in slovak) (National Standard of Gas Flow: Summary Report). Bratislava, SMU, (2007) 34.

    Google Scholar 

  5. S. Makovnik and D. Dopheide, Final Report from Bilateral Comparison Measurements between the SMU and the FTB in the Field of Flowrate and of the Delivered Volume of Gas, FTB-SMU, (2007).

  6. Š. Makovník, V. Zámečník, M. Stančíková, Národný etalón prietoku a prete čeného mno • stva plynu. (in Slovak) (National Standard of Gas Flow). Metrológia a skúšobníctvo, 13 (2008) 9–15.

    Google Scholar 

  7. H. Bettin, Deducing Calibration and Measurement Capabilities from Key Comparisons, Measurement, 42 (2009) 1429–1432.

    Article  Google Scholar 

  8. NIST/SEMATECH e-Handbook of Statistical Methods, http://www.itl.nist.gov/div898/handbook/pmc/section3/pmc31.htm

  9. ILAC-G24:2007 / OIML D 10:2007 Guidelines for the Determination of Calibration Intervals of Measuring Instruments.

  10. H.T. Castrup, et al, Metrology — Calibration and Measurement Processes Guidelines. NASA Reference Publication, 1342 (1994).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Miroslava Benkova.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Benkova, M., Makovnik, S., Mikulecky, I. et al. Bell prover — calibration and monitoring of time stability. MAPAN 26, 165–171 (2011). https://doi.org/10.1007/s12647-011-0016-3

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12647-011-0016-3

Keywords

Navigation