Abstract

Three bi-leaflet prostheses, the St. Jude Medical (SJM) and the On-X valves with straight leaflets and the MIRA valves with curved leaflets were tested in the aortic position under pulsatile-flow condition to find the design and other influences on aortic flow field and coronary circulation. The flow field affected by the valve-installed orientations, leaflet shapes, and valve designs were analyzed using Dynamic PIV system. Direct measurement of the coronary flow using ultrasonic flow meter was used to monitor coronary flow. Detailed chronological comparison of the flow fields downstream of the aortic valve and inside the sinus of valsalva and coronary flow revealed the overall valve effect on the flow and possible influence on the coronary flow.

Newer MIRA and On-X valves showed strong flow through the central orifice. The SJM and the newer On-X valve generate stronger circulatory flow inside the sinus of valsalva when valve orientation is set at 180..while the MIRA valve with curved leaflet generates stronger circulatory flow inside the sinus of valsalva when valve orientation is set at 90°. Coronary flow clearly shows the increase of flow rate when the circulatory flow inside the sinus of valsalva increase. This possibly indicate the positive correlation exist between the circulatory flow inside the sinus of valsalva and the coronary flow.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 349.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 449.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Akutsu, T., Matsumoto, A., Takahashi, K. (2011). In Vitro Study of the Correlation between the Aortic Flow Field Affected by the Bileaflet Mechanical Valves and Coronary Circulation. In: Jobbágy, Á. (eds) 5th European Conference of the International Federation for Medical and Biological Engineering. IFMBE Proceedings, vol 37. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-23508-5_200

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-23508-5_200

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-23507-8

  • Online ISBN: 978-3-642-23508-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics