Skip to main content

High-frequency Pulse-compression Ultrasound Imaging with an Annular Array

  • Conference paper
Acoustical Imaging

Part of the book series: Acoustical Imaging ((ACIM,volume 29))

Abstract

High-frequency ultrasound (HFU) allows fine-resolution imaging at the expense of limited depth-of-field (DOF) and shallow acoustic penetration depth. Coded-excitation imaging permits a significant increase in the signal-to-noise ratio (SNR) and therefore, the acoustic penetration depth. A 17-MHz, five-element annular array with a focal length of 31 mm and a total aperture of 10 mm was fabricated using a 25-μm thick piezopolymer membrane. An optimized 8-μs linear chirp spanning 6.5–32 MHz was used to excite the transducer. After data acquisition, the received signals were linearly filtered by a compression filter and synthetically focused. To compare the chirp-array imaging method with conventional impulse imaging in terms of resolution, a 25-μm wire was scanned and the -6-dB axial and lateral resolutions were computed at depths ranging from 20.5 to 40.5 mm. A tissue-mimicking phantom containing 10-μm glass beads was scanned, and backscattered signals were analyzed to evaluate SNR and penetration depth. Finally, ex-vivo ophthalmic images were formed and chirp-coded images showed features that were not visible in conventional impulse images.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. J. A. Ketterling, O. Aristizábal, D. H. Turnbull, and F. L. Lizzi, “Design and fabrication of a 40-mhz annular array transducer,” IEEE Trans. Ultrason. Ferroelect. Freq. Contr., vol. 52, pp. 672–681, 2005.

    Article  Google Scholar 

  2. J. A. Ketterling, S. Ramachandran, and O. Aristizábal, “Operational verification of a 40-mhz annular array transducer,” IEEE Trans. Ultrason. Ferroelect. Freq. Contr., vol. 53, pp. 623–630, 2006.

    Article  Google Scholar 

  3. T. Misaridis and J. A. Jensen, “Use of modulated excitation signals in medical ultrasound. part II: Design and performance for medical imaging applications,” IEEE Trans Ultrason Ferroelectr Freq Control, vol. 52, pp. 192–207, 2005.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer Science+Business Media B.V.

About this paper

Cite this paper

Mamou, J., Ketterling, J., Silverman, R. (2008). High-frequency Pulse-compression Ultrasound Imaging with an Annular Array. In: Akiyama, I. (eds) Acoustical Imaging. Acoustical Imaging, vol 29. Springer, Dordrecht. https://doi.org/10.1007/978-1-4020-8823-0_11

Download citation

Publish with us

Policies and ethics