Skip to main content

Quantitative Performance Evaluation of Mobile Cone-Beam CT for Head and Neck Imaging

  • Conference paper
  • First Online:
World Congress on Medical Physics and Biomedical Engineering 2018

Abstract

Cone-beam computed tomography (CBCT) has become increasingly popular in dental and maxillofacial imaging due to its accurate 3D information, minimal radiation dose, and low machine cost. In this paper, we propose the newly developed mobile CBCT scanner which combines the benefits of CBCT and mobility to extend its applications to head and neck imaging and allow faster access to a patient at various clinical sites. With the large area detector, only a single rotation is needed to reconstruct the field-of-view of almost the entire head. Our filtered back-projection reconstruction and artifact reduction algorithms were based on a graphics processing unit to speed up the calculations. The quantitative performance was evaluated in terms of radiation doses and image quality. The radiation doses were measured using both CT dose index and dose area product (DAP) and compared with other CBCT and multi-slice CT (MSCT) machines. Then, we analyzed image quality using the standard cone-beam phantom. The effective doses radiated from the proposed mobile CBCT machine were within the range of 0.1–0.2 mSv, while the normalized DAP measurements were within the range of 46–144 mGy cm2, which are significantly below the achievable dose of 250 mGy cm2. The overall image quality of the proposed scanner was mostly comparable to other MSCT and CBCT scanners. Geometric accuracy of the reconstructed images provided the errors less than 0.16 mm or 0.12%. Due to low radiation dose, high accuracy and adequate image quality as compared to others, the proposed mobile CBCT has high potential for diagnosis and treatment planning in head and neck applications.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. De Vos W, Casselman J, and Swennen GRJ. Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region. A systematic review of the literature. Int J Oral Maxillofacial Surgery. 2009;38;609–625.

    Google Scholar 

  2. Ludlow JB, and Ivanovic M. Comparative dosimetry of dental CBCT devices and 64-slices CT for oral and maxillofacial radiology. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology. 2008;106(1):106–114.

    Google Scholar 

  3. Thongvigitmanee SS, Pongnapang N, Aootaphao S, Yampri, Srivongsa T, Sirisalee P, Rajruangrabin J, and Thajchayapong P. Radiation dose and accuracy analysis of newly developed cone-beam CT for dental and maxillofacial imaging. Proc. of the IEEE Engineering in Medicine and Biology Society. 2013;2356–2359. https://doi.org/10.1109/embc.2013.6610011.

  4. Aootaphao S, Thongvigitmanee SS, Rajruangrabin J, Yampri P, Srivongsa T, and Thajchayapong P. Fast scatter correction for cone-beam computed tomography using the statistical method. Proc. of the IEEE Nuclear Science Symposium and Medical Imaging Conference. 2013. https://doi.org/10.1109/nssmic.2013.6829350.

  5. Kosalagood P, Silkosessak OC, Pittayapat P, Pisarnturakit P, Pauwels R and Jacobs R. Linear measurement accuracy of eight cone beam computed tomography scanners. Clinical Implant Dentistry and Related Research. 2014;1–11. https://doi.org/10.1111/cid.12221.

  6. Khongkhunthian P, Jomjunyong K, and Reichart PA. Accuracy of cone beam computed tomography for dental implant treatment planning. CMU J Nat Sci 2017;16(1):51–62.

    Google Scholar 

  7. Holroyd JR, and Walker A. Recommendations for the design of X ray facilities and the quality assurance of dental cone beam CT (computed tomography) systems—a report of the HPA working party on dental cone beam CT. HPA-RPD-065. Health Protection Agency; 2010.

    Google Scholar 

  8. Pauwels R, Theodorakou C, Walker A, Bosmans H, Jacobs R, Horner K, Bogaerts R, and The SEDENTEXCT Project Consortium. Dose distribution for dental cone beam CT and its implication for defining a dose index. Dentomaxillofacial Radiology. 2012;41(7):583–593.

    Google Scholar 

  9. Feldkamp LA, Davis LC, Kress JW. Practical cone-beam algorithm. Journal of the Optical Society of America A 1984;1(6):612–619.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Saowapak S. Thongvigitmanee .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Thongvigitmanee, S.S. et al. (2019). Quantitative Performance Evaluation of Mobile Cone-Beam CT for Head and Neck Imaging. In: Lhotska, L., Sukupova, L., Lacković, I., Ibbott, G.S. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/1. Springer, Singapore. https://doi.org/10.1007/978-981-10-9035-6_12

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-9035-6_12

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-9034-9

  • Online ISBN: 978-981-10-9035-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics