Abstract
A study of the Exceptional shut down during load test of emergency diesel generator (EDG) was performed for M310 unit (1000 mW). An EDG protection shut down was executed during the EDG load test after finishing synchronizing with power grid in an M310 unit, generator circuit-breaker (GCB) opened automatically, but no protection shut down signal or alarm had been recorded except low lube oil pressure alarm. The reason of the protection shut down was analyzed in this article, modification was introduced to reduce the risk of damaging EDG.