Abstract
Infrared thermography (IRT) is a non-destructive evaluation technique that is used to visualize construction deficiencies, e.g. thermal bridges. In combination with a pressurization fan, IRT is also used to detect air leakages. The surface temperature change caused by the leakage air can be monitored by taking multiple IR images. Is it possible to assess the severity or quantify the flow of air leakages with this method? In order to link infrared images to the magnitude of air leakage flow, all influencing factors on the change in the surface temperature were examined in simulation models, laboratory and in situ measurements. The research showed that the visibility of an air leak is dependent on the position of other surfaces nearby. Consequently, the amount of air leakage flow cannot be related to the surface temperature change viewed on multiple IR images. Next to visibility issues, the change in surface temperature is proven to be smaller at large air leakage spots. This is due to the constant influence of the leakage air on the surface temperatures. Thermography is a sufficient technique for the visualization of air leakages that cause a clear surface temperature pattern under a pressure difference. However, it is not possible to derive the quantity of the air leakage flow.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
AIVC (1994) Technical note 44—an analysis and data summary of the AIVC’s numerical database. Air Infiltration and Ventilation Centre
ASTM E1862-97 (2002) Standard test method for measuring and compensating for reflected temperature using infrared imaging radiometers. ASTM American society for testing and materials
ASTM E1993-99a (2005) Standard test method for measuring and compensating for emissivity using infrared imaging radiometers. ASTM American society for testing and materials
Barreira E, de Freitas S, de Freitas V, Delgado J (2013) Infrared thermography application in building diagnosis: a proposal for test procedures. In: Infrared thermography application in building diagnosis. Springer, Heidelberg, pp 91–117
Bérubé Dufour M, Derome D, Zmeureanu R (2009) Analysis of thermograms for the estimation of dimensions of cracks in the building envelope. Infrared Phys Technol 52:70–78
Blocken B, Defraeye T, Derome D, Carmeliet J (2009) High-resolution CFD simulations for forced convective heat transfer coefficients at the facade of a low-rise building. Build Environ 44(12):2396–2412
Charlier L (2007) Utilisation de la thermographie infrarouge pour la determination des déperditions thermique d’un bätiment. Université de Liège, Liège
Dall’O G (2013) Infrared Audit. In: Green energy audit of buildings. Springer, London, pp 111–125
Dewulf B, Goetelen C (2015) Opsporen en kwantificeren van luchtlekken in de gebouwschil aan de hand van thermografie. Universiteit Gent, Vakgroep Architectuur en stedenbouw, Gent (in Dutch)
Eads L, Epperly R, Snell J (2000) Thermography: practical guide. ASHRAE J 51–55
FLIR Systems (2012) Thermal camera guide for research professionals. FLIR, Boston
Hens H (2012) Building physics-heat, air and moisture. Ernst & Sohn, Berlin
Jewett J, Serway R (2008) Physics for scientists and engineers with modern physics. Thomson Higher Education, Belmont
Kalamees T (2007) Airtightness and air leakages of new lightweight single-family detached houses in Estonia. Build Environ 42:2369–2377
Loveday D, Taki A (2001) Section 3: heat transfer. In: Compton P, Jones W, Loveday D, Purvis M, Watson A (eds) Reference data, CIBSE guide C. Butterworth-Heinermann, London, pp 84–92
Meola C, Carlomango G (2004) Recent advances in the use of infrared thermography. Measure Sci Technol 15:27–58
NBN EN 13187 (n.d.) Thermal performance of buildings—qualitative detection of thermal irregularities in building envelopes-infrared method. Bureau voor Normalisatie, Brussels
NBN EN 13829 (2001) Thermal performance of buildings-determination of air permability of buildings-fan pressurization method. Belgisch Bureau voor normalisatie, Brussels
Pearson C (2011) Thermal imaging of building fabric (BSRIA Guide 39). BSRIA 30
Physibel V (2008) 3-dimensional dynamic simulation tool using the finite element method (Version 7.0 ed), Maldegem
RESNET (2012) Interim guidelines for thermographic inspections of buildings. RESNET Residential energy services network
Senave E, Standaert P, Walleyn B, Wouters P (1990) Annex 14 condensation and energy. The International Energy Agency (IEA)
Van De Vijver S, Steeman M, Van Den Bossche N, Carbonez K, Jansenss A (2014) The influence of environmental parameters on the thermographic analysis of the building envelope. QIRT, Bordeaux, p 10
Van Den Bossche N, Huyghe W, Moens J, Janssens A, Depaep M (2012) Airtightness of the window-wall interface in cavity brick walls. Energy Build 45:32–42
Willockx A (2010) Using the inverse heat conduction problem and thermography for the determination of local heat transfer coefficients and fin effectiveness for longitudinal fins. Doctoral paper, 283. Universiteit Gent, Gent
Acknowledgments
The research has been financed by the Flemish Institute for the Promotion and Innovation by Science and Technology in Flanders (IWT 130210). Their financial support is greatly acknowledged. Next to that, the authors would also like to thank Bieke Dewulf and Cleo Goetelen, who executed the in situ measurements for their master dissertation.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer Science+Business Media Singapore
About this chapter
Cite this chapter
Maroy, K., Van Den Bossche, N., Steeman, M., Van De Vijver, S. (2016). On the Use of Infrared Thermographic Measurements for Evaluating the Airtightness of the Building Envelope. In: Delgado, J. (eds) Recent Developments in Building Diagnosis Techniques. Building Pathology and Rehabilitation, vol 5. Springer, Singapore. https://doi.org/10.1007/978-981-10-0466-7_9
Download citation
DOI: https://doi.org/10.1007/978-981-10-0466-7_9
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-0465-0
Online ISBN: 978-981-10-0466-7
eBook Packages: EngineeringEngineering (R0)