Abstract
The purpose of this research is to understand the fire behavior expected in a mechanically ventilated compartment. To date, some experimental studies have been conducted for investigation of fire behavior under mechanical forced ventilation; however, it might be not enough to understand everything. We therefore carried out a series of experiments on fire behavior focused on the effect of air inlet position in a compartment with same size as an ISO 9705 room (width 2.4 m × length 3.6 m × height 2.4 m) under conditions of mechanical ventilation using a pool fire. In this paper, the effects of ventilation conditions such as air inlet position and flow rate were studied. We found that differences in the air inlet position and flow rate were one of the principal factors for determining the burning behavior.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Tanaka T, Kabasawa Y, Soutome Y, Fujizuka M (1986) Preliminary test for full scale compartment fire test (lubricant oil fire test: part 1). In: Fire safety science – proceedings of the 1st international symposium, International Association for Fire Safety Science, pp 799–808. doi:10.3801/IAFSS.FSS.1-799
Foote KL, Pagni PJ, Alvares NJ (1986) Temperature correlations for forced-ventilated compartment fires. In: Fire safety science – proceedings of the 1st international symposium, International Association for Fire Safety Science, pp 139–148. doi:10.3801/IAFSS.FSS.1-139
Peatross MJ, Beyler CL (1997) Ventilation effects on compartment fire characterization. In: Fire safety science – proceedings of the 5th international symposium, International Association for Fire Safety Science, pp 403–414. doi:10.3801/IAFSS.FSS.5-403
Chow WK, Tsui SC (1998) Temperature distribution induced by fires in a small chamber with forced ventilation. J Fire Sci 16(2):125–145. doi:10.1177/073490419801600204
Mizuno K, Tanaka S, Hasemi Y (1992) A model experimental study of force-ventilated fires in a highly air tight enclosure: general characteristics of combustion and conditions of a heavy carbon monoxide generation. J Archit Plan Environ Eng 435:137–145, (in Japanese)
Sano T, Shirai K, Hattori Y, Suto H, Tsuchino S (2013) Comprehension of limited ventilated fire behavior and study on fire prediction method in an enclosed space. Trans Atmoic Energy Soc Jpn 12:32–42, (in Japanese)
Prétrel H, Le Saux W, Audouin L (2012) Pressure variations induced by a pool fire in a well-confined and force-ventilated compartment. Fire Saf J 52:11–24
Vaux S, Prétrel H (2013) Relative effects of inertia and buoyancy on smoke propagation in confined and forced ventilated enclosure fire scenarios. Fire Saf J 62(Part B):206
Prétrel H, Le Saux W, Audouin L (n.d.) Determination of the heat release rate of large scale hydrocarbon pool fires in ventilated compartments. Fire Saf J 62(Part B): 192
Audouin L, Rigollet L, Prétrel H, Le Saux W, Röwekamp M (2013) OECD PRISME project: fires in confined and ventilated nuclear-type multi-compartments – overview and main experimental results. Fire Saf J 62(Part B):80
Hattori Y, Matsuyama K, Suto H, Onuma E, Okinaga S (2014) Turbulence measurements in a ventilation-controlled pool fire. In: Proceedings of 16th international symposium on flow visualization
Hattori Y, Matsuyama K, Suto H, Onuma E, Okinaga S (2014) Entrainment process in the vicinity of pool fire under ventilation condition. In: Proceedings of the 15th international heat transfer conference, 09377
Niioka T, Kono M, Sato J (2001) Fundamentals of combustion phenomena, Ohmsha, pp 180–186, (in Japanese)
He Y, Fernando A, Luo M (1998) Determination of interface height from measured parameter profile in enclosure fire experiment. Fire Saf J 31:19–38
Acknowledgment
The authors would like to thank Mrs. Y. Terada and T. Mizuno for helps in the experiments.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer Science+Business Media Singapore
About this paper
Cite this paper
Matsuyama, K., Okinaga, S., Hattori, Y., Suto, H. (2017). Experimental Study on Fire Behavior in a Compartment Under Mechanical Ventilated Conditions: The Effects of Air Inlet Position. In: Harada, K., Matsuyama, K., Himoto, K., Nakamura, Y., Wakatsuki, K. (eds) Fire Science and Technology 2015. Springer, Singapore. https://doi.org/10.1007/978-981-10-0376-9_11
Download citation
DOI: https://doi.org/10.1007/978-981-10-0376-9_11
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-0375-2
Online ISBN: 978-981-10-0376-9
eBook Packages: EngineeringEngineering (R0)