Abstract
The effect of ectopic atrial beats on the natural pacemaker of the heart has been discussed among electrophysiologists since a long time (Engelmann, 1897; Cushny and Matthews, 1897; Wenckebach, 1903). The advent of the microelectrode technique made it possible to study the response of single sinoatrial pacemaker cells to premature atrial beats (Bonke et al., 1969 and 1971; Klein et al., 1973; Miller and Strauss, 1974). Recently, Strauss et al. (1973) suggested that the premature atrial stimulation technique may be used for indirect assessment of sinoatrial conduction time in man. This method takes advantage of the fact that the length of the atrial cycle following an ectopic beat, which occurs early enough to discharge the sinus node, is determined by the sum of: (1) retrograde conduction time of the premature impulse from the atrium to the pacemaker center in the sinus node, (2) postextrasystolic pacemaker cycle, and (3) antegrade conduction time from the pacemaker center to the atrium. If there occurs no pacemaker shift within the sinus node and if the rate of pacemaker discharge is not influenced by the premature beat, the difference between the postextrasystolic atrial interval and the basic atrial cycle can be attributed to the sum of retrograde and antegrade sinoatrial conduction time. If one further assumes that antegrade and retrograde sinoatrial conduction velocities are equal, half of this time will give a calculated value for unidirectional sinoatrial conduction time.
Supported by a grant of the “Deutsche Forschungsgemeinschaft” (Ste 257/1 and Ste 257/2) to G. Steinbeck.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
REFERENCES
Bonke, F.I.M.: Electrotonic spread in the sinoatrial node of the rabbit heart. Pflügers Arch 339: 17, 1973
Bonke, F.I.M., Bouman, L.N., Van Rijn, H.E.: Change of cardiac rhythm in the rabbit after an atrial premature beat. Circ Res 24: 533, 1969
Bonke, F.I.M., Bouman, L.N., Schopman, F.J.G.: Effect of an early atrial premature beat on activity of the sinoatrial node and atrial rhythm in the rabbit. Circ Res 29: 704, 1971
Cushny, A.R., Matthews, S.A.: On the effects of electrical stimulation of the mammalian heart. J Physiol (London) 21: 213, 1897
Engelmann, T.W.: Über den Ursprung der Herzbewegung und die physiologischen Eigenschaften der grossen Herznerven des Frosches. Arch f d ges Physiol 65: 109, 1897
Klein, *11.0., Singer, D.H., Hoffman, B.F.: Effects of atrial premature systoles on sinus rhythm in the rabbit. Circ Res 32: 480, 1973
Miller, H.C., Strauss, H.C.: Measurement of sinoatrial conduction time by premature atrial stimulation in the rabbit. Circ Res 35: 935, 1974
Sano, T., Yamagishi, S.: Spread of excitation from the sinus node. Circ Res 16: 423, 1965
Schreurs, A.W., Meijer, A.A., Bouman, L.N., Bonke, F.I.M.: Micromanipulator with an electrode driver used for microelectrode work. Pflügers Arch 346: 163, 1974
Seyama, I.: Characteristics of the rectifying properties of the sinoatrial node cell of the rabbit. J Physiol 255: 379, 1976
Steinbeck, G., Körber, H.J., Lüderitz, B.: Die Bestimmung der sinuatrialen Leitungszeit beim Menschen durch gekoppelte atriale Einzelstimulation. Klin Wschr 52: 1151, 1974
Strauss, H.C., Saroff, A.L., Bigger, J.T., Giardina, E.G.V.: Premature atrial stimulation as a key to the understanding of sinoatrial conduction in man. Circulation 47: 86, 1973
Wenckebach, K.F.: Über die Dauer der compensatorischen Pause nach Reizung der Vorkammer des Säugethierherzens. Arch Anat Physiol, 57–64, 1903
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1978 Martinus Nijhoff Medical Division
About this chapter
Cite this chapter
Steinbeck, G., Allessie, M.A., Bonke, F.I., Lammers, W.J. (1978). The Response of the Sinus Node to Premature Stimulation of the Atrium Studied with Microelectrodes in Isolated Atrial Preparations of the Rabbit Heart. In: Bonke, F.I.M. (eds) The Sinus Node. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-9715-8_8
Download citation
DOI: https://doi.org/10.1007/978-94-009-9715-8_8
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-9717-2
Online ISBN: 978-94-009-9715-8
eBook Packages: Springer Book Archive