Skip to main content

Biosensors for the Control of Some Toxins, Viral and Microbial Infections to Prevent Actions of Bioterrorists

  • Conference paper
  • First Online:
Portable Chemical Sensors

Abstract

Foodborne toxins are very widespread and very dangerous for health of people. It is very important to control the level of T2 mycotoxin which has a high toxic effect and may serve as biological weapons and agent for bioterrorism. From other side Salmonellosis is the most common enteric infection. Retroviral bovine leucosis is very dangerous too since the level of ailing people correlates with the amount of sick animals in the area of habitat.

The most effective way to prevent not desirable results is in constant monitoring of the epidemiological situation. It may be done with the help of instrumental ­analytical approaches based on the principles of biosensorics. They may provide selective, high sensitive, simple and express analysis which may be fulfilled in “on line” regime and in field conditions. These approaches may be completed by the special GSM system for immediately transferring results of analysis in the specialized laboratory for appropriate action. In the article the development of authors of the immune biosensors for monitoring of toxins, bacteria and biochemical diagnostics of retroviral leukemia through analysis of blood and milk are analyzed. The main attention is paid the optical biosensors based on the surface plasmon resonance (SPR) and total internal reflection ellipsometry (TIRE) as well as photoluminescence (PhL) and photoconductivity (PhC) of nanostructured (sNPS) porous silicon. The characteristics of the immune biosensors may be changed by varying procedures of the preliminary preparation of the transducer surface. The special attention is paid to the developed procedures of the preparation of samples for analysis. At the final part of article in short form the preliminary results obtained at the application of some approaches for the simple and rapid decontamination of aquatic environments from number of toxic substances are considered.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Roberts B, Moodie M (2002) Toward a threat reduction strategy. Nat Defense Univ. http://www.ndu.edti/iass/pms/ndttithfi.htmt

  2. Mirocha CJ, Pawlosky RA, Chatterjee K et al (1983) Analysis for Fusarium toxins in various samples implicated in biological warfare in Southeast Asia. J Assoc Anal Chem 66(6):1485–1499

    CAS  Google Scholar 

  3. Rosen RT, Rosen JD (1982) Presence of four Fusarium mycotoxins and synthetic material in yellow rain. Evidence for the use of chemical weapons in Laos. Biomed Mass Spectrom 9(10):443–450

    Article  CAS  Google Scholar 

  4. Morris BA, Clifford MN (eds) (1985) Immunoassays for food analysis. Elsevier Applied Science, London/New York

    Google Scholar 

  5. Rittenburg JH (ed) (1990) Development and application of immunoassay for food analysis. Elsevier Applied Science, London/New York

    Google Scholar 

  6. Iqbal SS, Mayo MW, Bruno JG et al (2000) A review of molecular recognition technologies for detection of biological threat agents. Biosens Bioelectron 15(11–12):549–578

    Article  CAS  Google Scholar 

  7. Nabok AV, Tsargorodskaya A, Hassan AK, Starodub NF (2005) Total internal reflection ellipsometry and SPR detection of low molecular weight environmental toxins. Appl Surf Sci 246:381–386

    Article  CAS  Google Scholar 

  8. Starodub NF, Nabok AV, Tsargorodskaya A, Gojster OS, Khmelnitsky GO (2006) Control of T2 mycotoxin in solutions and foods by biosensors based on SPR and TIRE. In: Proceedings of the international conference “Sensor  +  Test 2006”, Nuremberg, Germany, pp 87–92

    Google Scholar 

  9. Starodub NF, Nazarenko VI, Ivashkevich SP, Goncharuk VV, Klimenko NA (2006) Principles of express instrumental control of total toxicity of environmental objects and their realization in space conditions. In: Proceedings of the Society of Automotive Engineers (SAE), Norfolk

    Google Scholar 

  10. Starodub NF, Mel’nik VG, Shmireva OM (2006) Instrumental approaches and peculiarities of design of stationary and portable analytical devices for determination of bio- and chemi-luminescence. In: Proceedings of the Society Automotive Engineers (SAE), Norfolk

    Google Scholar 

  11. ISO 6341:1996(E), Water quality – Determination of the mobility of Daphnia magna Strains(Cladocera, Crustacea) – Acute toxicity test

    Google Scholar 

  12. Ivashkevich SP, Levkovetz SP, Nazarenko VI, Starodub NF (2002) Chemiluminescence of medium Daphnia cultivation and optimization of conditions of it determination. Ukr Biochem J 74(3):93–97

    CAS  Google Scholar 

  13. Gojster OS, Starodub NF, Chmel’nitskij GA (2003) Determination of T2 mycotoxin by chemiluminescent method with the use of Daphnia. Hydrobiol J 58(5):85–91

    Google Scholar 

  14. Katzev AM, Gojster OS, Starodub NF (2003) Influence of T2 mycotoxin on the intensity of bacterial bioluminescence. Ukr Bioch J 75(3):99–103

    Google Scholar 

  15. Starodub NF, Pilipeko LN, Pilipenko IV, Egorova AV (2008) Mycotoxins and other low weight toxins as instrument of bioterrorists: express instrumental control and some ways to decontaminate polluted environmental objects. Timisoara Med J 58(1–2):9–18

    Google Scholar 

  16. Elnabarawy MT, Robideau RR, Beach SA (1988) Comparison of three rapid toxicity test ­procedures: Microtox, Polytox and activated sludge respiration inhibition. Toxicity Assess 3:361–370

    Article  CAS  Google Scholar 

  17. Manfoud R, Maresca M, Garmy N, Fantini J (2002) The mycotoxin patulin alters the barrier function of the intestinal epithelium: mechanism of action of the toxin and protective effects of glutathione. Toxicol Appl Pharmacol 181:209–218

    Article  Google Scholar 

  18. Starodub NF, Starodub VM (2000) Immune sensors: origins, achievements and perspectives. Ukr Biochem J 72:147–163

    CAS  Google Scholar 

  19. Starodub NF, Kanjuk MI, Kukla AL, Shirshov YM (1999) Multi-enzymatic electrochemical sensor: field measurements and their optimization. Anal Chim Acta 385:461–466

    Article  CAS  Google Scholar 

  20. Yazynina EV, Zherdev AV, Dzantiev BB, Izumrudov VA, Gee Sh J, Hammock BD (1999) Immunoassay techniques for determination of the herbicide simazine based on use of oppositely charged water-soluble polyelectrolytes. Anal Chem 71:3538–3543

    Article  CAS  Google Scholar 

  21. Starodub VM, Starodub NF (1999) Electrochemical immune sensor based on the ion-selective field effect transistor for the determination of the level of myoglobin. In: Proceedings of the 13th European conference on solid-state transducers, The Hague, pp 185–188, 12–15 Sept 1999

    Google Scholar 

  22. Starodub NF, Dzantiev BB, Starodub VM, Zherdev AV (2000) Immunosensor for the determination of the herbicide simazine based on an ion-selective field effect transistor. Anal Chim Acta 424:37–43

    Article  CAS  Google Scholar 

  23. Starodub NF, Starodub VM (2001) Biosensors and control of pesticides in water and foods. Chem Technol Water 6:612–638

    Google Scholar 

  24. Shirshov YM, Starodub NF, Kukla AL, Kanjuk MI (1997) Creation of the multi-enzymatic sensor for simultaneous determination of phosphororganic pesticides and heavy metal ions in solutions. In: Proceedings of the 11th European conference on solid-state transducers Eurosensors XI, Warsaw, Poland, pp 727–30, 21–24 Sept 1997

    Google Scholar 

  25. Starodub NF, Torbicz W, Pijanowska D, Starodub VM, Kanjuk MI, Dawgul M (1998) Optimization methods of enzyme integration with transducers for analysis of irreversible inhibitors. In: White NM (ed) Proceedings of the XII European conference on solid-state transducers and the IX UK conference on sensors and their applications, vol 1, Southampton, UK, Institute of Physics, Bristol, pp 837–840. 13–16 Sept 1998

    Google Scholar 

  26. Starodub NF, Starodub VM, Kanjuk NI, Kukla AL, Shirsjov YM (1999) Biological sensor array for express determination of a number of biochemical quantities. In: Proceedings of the 2nd EUREL workshop “European advanced robotic system development medical robotics”, Piza, Italy, pp 57–64, 23–24 Sept 1999

    Google Scholar 

  27. Starodub NF, Brezvin OM (2011) Immune biosensor based on the oxide cerium IsFETs for the determination of mycotoxin level in environmental objects. In: Book abstracts of international conference “LabAutomation2011”, Palm Springs, p 65

    Google Scholar 

  28. Kotsyumbas IJa, Brezvin OM, Starodub NF (2010) Oxide cerium IsFETs: physical and functional characteristics at the determination of some biochemical quantities. In: Abstract Of 4-th international scientific-technology conference Sensors electronics and Microsystem Technol (SEMST-4), Odessa, pp 88–89, 28 June-02 July 2010

    Google Scholar 

  29. Starodub NF (1990) Electrochemical biosensors and biochemical diagnostics // In book: lecture notes of the int. sensors center of biocybernetics of the Academies of Science of the Socialist Countries, vol 3, Jablonna, pp 173–202

    Google Scholar 

  30. Nabok AV, Tsargorodskaya A, Holloway A, Starodub NF, Gojster O (2007) Registration of T2mycotoxin with total internal reflection ellipsometry and QCM impedance methods. Biosens Bioelectron 22:885–890

    Article  CAS  Google Scholar 

  31. Kachinskaya TS, Shmyryeva OM, Mel’nichenko MM, Yurevich EP, Starodub MF (2009) Production of Biosensor Controls on the Basis of Nanostructured Silicon. e-J Surf Sci Nanotechnol 7:677–680

    Article  CAS  Google Scholar 

  32. Starodub NF, Shulyak AM, Shmyryeva AB, Pylypenko IV, Pylypenko LN, Mel’nichenko MM (2010) Nanostructured silicon and its application as a transducer in immune biosensor. In: Mikhalovsky S, Khajibaev A (eds) NATO book “Biodefence” sciences for peace and science security series A chemistry and biology, Springer Science  +  Business Media, Dordrecht, Chapter 9, pp 87–98

    Google Scholar 

  33. Starodub NF, Pylypenko IV, Pylypenko LN, Mel’nichenko MM, Nabok AV (2010) Biosensors for the determination of mycoyoxins: development, efficiency at the analysis of model samples and in case of the practical applications. In book: “Lecture notes of the ICB”, vol 86, pp 81–101

    Google Scholar 

  34. Nabok AV, Mustafa MK, Tsargorodskaja A, Starodub NF (2011) Detection of aflatoxin B1 with a label free ellipsometry immunobiosensor. BioNanoSci 1(1):38–45

    Google Scholar 

  35. Pylypenko IV, Pylypenko LN, Starodub NF, Brezvin OM (2010) Biosensors at the determination of mycotoxins. In: Abstract of 4-th International Scientific-Technology Conference Sensors electronics and Microsystem Technol. (SEMST-4), Odessa, p 227, 28 June–02 July 2010

    Google Scholar 

  36. Starodub NF, Ogorodnijchuk YuA, Romanov VO, Galeljuka IB, Kushnir IM, Kotsjumbas IYa (2010) Optical immune biosensor based on the surface Plasmon resonance for the control of Salmonella tiphimurium level in solutions. Scientific Herald, 151, Ser. “vet. Med. And Biosafety of foods”, vol 2, pp 183–189

    Google Scholar 

  37. Ogorodnijchuk YuA, Starodub NF (2010) Development of optical biosensor based on the ­surface plasmon resonance for the control of the level of the pathogenic microorganisms. In; Proceedings of abstracts of international conference. “Young Scientists and gait of young”, Lvov, 21–24 September, 2010, pp 163–164.

    Google Scholar 

  38. Starodub NF, Ogorodnijchuk JuA, Romanov VO. Optical immune biosensor based on SPR for the detection of Salmonella typhimurium. In: Abstract book: “The SENSOR+TEST 2011 conference”, Nurenberg, 2011, P7

    Google Scholar 

  39. Ivnitski D, Abdel-Hamid I, Atanasov P, Wilkins E (1999) Biosensors for detection of pathogenic bacteria. Biosens Bioelectron 14:599–624

    Article  CAS  Google Scholar 

  40. Gertie CAM, Bokken GC, Corbee RJ, van Knapen F, Bergwerff AA (2003) Immunochemical detection of Salmonella group B, D and E using an optical surface plasmon resonance biosensor. J FEMS Microbiol Lett 222:75–82

    Article  Google Scholar 

  41. Koubova V, Karasova L, Skvot J, Homola J, Dostalek J, Tobiska P, Rosicky J (2001) Detection of foodborne pathogens using surface plasmon resonance biosensors. Sens Actuators B Chem 74:100–105

    Article  Google Scholar 

  42. Starodub VM, Starodub NF et al (2001) Electrochemical and optical biosensors: origin of development, achievements and perspectives of practical application. In: Bozoglu F (ed) NATO series “Novel processes and control technologies in the food industry. IOS Press, Amsterdam, pp 63–94

    Google Scholar 

  43. Starodub NF, Arthjuch VP, Pirogova LV, Nagajeva LI, Dobrosol GI, Pavlenko M (2001) Grotevich VExpress diagnostics of bovine leucosis on the basis of biosensor analysis. Vet Med N11:26–27

    Google Scholar 

  44. Starodub NF, Pirogova LV, Artyukh VP, Starodub VN (2002) Biospecific interactions on the optical transducer surface the base of infection diagnostics. In: Buzaneva E, Scharff P (eds) NATO ARW frontiers of multifunctional nanosystems, vol 57. Kluwer Academic Publishers, Dordrecht, pp 369–376

    Google Scholar 

  45. Starodub NF, Starodub VN (2003) Infectious bovine leucosis and its diagnostics. Biopolym Cell 19:307–316

    Google Scholar 

  46. Starodub MF, Romanov VO, Kochan RV, Sachenko AO, Kochan OV (2006) Implementation of SPR-biosensors for express-diagnostics of acute viral infection and mycotoxicosis. Bull Khmelnitski Natl Univ N6:223–226

    Google Scholar 

  47. Caruso F, Niikura K, Furlong DN (1997) Assembly of alternating polyelectrolyte and protein multilayer films for immunosensing. Langmuir ACS J Surf Coll 13(13):3427–3433

    Article  CAS  Google Scholar 

  48. Pirogova LV, Starodub NF (2008) Immobilization of bovine leucosis antigen on the immune biosensor surface. Biotechnology 1(2):52–58

    Google Scholar 

  49. Starodub NF et al (2010) Modern biooptical instruments for the express control of total ­toxicity, individual chemicals, viral and bacterial infections to prevent bio- and medical threats. In: Trufanov A (ed) NATO science for peace and security series E: human and social ­dynamics, vol 62, Pandemics and Bioterrotism. IOS Press, Washington, DC, pp 127–133

    Google Scholar 

  50. Starodub NF, Starodub VM, Fedorenko LL, Dikiy SP (1996) Usage of the silicium crystal photoluminescence to registrate immunocomplex formation. In: Proceedings of the sixth international meeting on chemical sensors, July 22–25, 1996, NIST, Gaitersburg, 1996, p 248

    Google Scholar 

  51. Starodub VM, Fedorenko LL, Starodub NF (1998) Control of a myoglobin level in solution by the bioaffinic sensor based on the photoluminescence of porous silicon. In: Eurosensors XII and 9 th UK conference on sensors and their applications, Southampton, UK, 13–16 Sept 1998, 2, pp 817–820

    Google Scholar 

  52. Starodub VM, Starodub NF (1999) Optical immune sensors for the monitoring protein substances in the air. In: Eurosensor XII and 13th European conference on solid-state transducers. The Hague, 12–15 Sept 1999, pp 181–184

    Google Scholar 

  53. Starodub VM, Fedorenko LL, Sisetskiy AP, Starodub NF (1999) Control of mioglobin level in an immune sensor based on the photoluminescence of porous silicon. Sens Actuators B58:409–414

    CAS  Google Scholar 

  54. Starodub VM, Fedorenko LL, Starodub NF (2000) Optical immune sensor for the monitoring protein substances in the air. Sens Actuators B68:40–47

    CAS  Google Scholar 

  55. Starodub NF, Shmyryeva O, Mel’nichenko M, Romanov V, Shuljak L (2010) Modern analytical devices for the express diagnostics and environmental monitoring: working prototypes, their characteristics and practical application. In: Abstracts of LabAutomation2010 conference, January 24–27, Palm Springs, p 61

    Google Scholar 

  56. Starodub NF, Shmireva OM, Shuliak LM (2010) Multi-parametrical and multi-functional microelectronic biosensors. In: Abstracts of LabAutomation2010 conference, January 24–27, Palm Springs, p 124

    Google Scholar 

  57. Starodub NF, Shmiryeva OM (2010) Multi-parametrical and multi-functional microelectronic biosensors for the medical applications. In: Abstract of 4-th international scientific-­technoloogy conference. “Sensors electronics and microsystem technol” (SEMST-4), Odessa, pp 90–91, 28 June–02 July 2010

    Google Scholar 

  58. Kalchenko OI, Solovyov AV, Cherenok SA, Starodub NF, Kalchenko VI (2003) Complexation of calix[4]arenephosphonous acids with 2,4-dichlorophenoxyacetic acid and atrazine in water. J Incl Phenom Microcycl Chem 46:19–25

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nickolaj F. Starodub .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer Science+Business Media B.V.

About this paper

Cite this paper

Starodub, N.F., Ogorodniichuk, Y.A., Sitnik, Y.A., Slishik, N.F. (2012). Biosensors for the Control of Some Toxins, Viral and Microbial Infections to Prevent Actions of Bioterrorists. In: Nikolelis, D. (eds) Portable Chemical Sensors. NATO Science for Peace and Security Series A: Chemistry and Biology. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-2872-1_5

Download citation

Publish with us

Policies and ethics