Abstract
This paper presents the human blood reheating technique for the blood tissues after surgery as 37–51 °C temperature is required during surgery with high frequency induction heating system. The surgeon opens the chest by dividing the breastbone (sternum) and connects with the heart-lung machine to operate on the heart. This machine allows the surgeon to operate directly on the heart by performing the functions of the heart and lungs. The length of the operation will depend on the type of surgery that is required for patient. Most surgeries take at least 4–5 h. The preparation for surgery, which requires approximately 45–60 min included in this time. After this operation the patients has required high temperature blood for the continuation of blood flow to the heart as the human body temperature is decreases after operation. Here high frequency converter technique can give better topology for reheating the blood after open heart surgery by taking least time than conventional system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Sharkey A, Gulden RH, Lipton JM, Giesecke AH (1993) Effect of radiant heat on the metabolic cost of postoperative shivering. Br J Anaesth 70:449–450
Sessler DI, Moayeri A (1990) Skin-surface warming: heat flux and central temperature. Anesthesiology 73:218–224
Shander A, Hofmann A, Gombotz H, Theusinger OM, Spahn DR (2007) Estimating the cost of blood: past, present, and future directions. Best Pract Res Clin Anaesthesiol 21:271–289
Burns JM, Yang X, Forouzan O, Sosa JM, Shevkoplyas SS (2012) Artificial micro vascular network: a new tool for measuring rheologic properties of stored red blood cells. Transfusion 52(5):1010–1023
Van Beekvelt MC, Colier WN, Wevers RA, van Engelen BG (2001) Performance of near-infrared spectroscopy in measuring local O2 consumption and blood flow in skeletal muscle. J Appl Physiol 90(2):511–519. PMID 11160049
Sinha D, Sadhu PK, Pal N (2012) Design of an induction heating unit used in Hyperthermia treatment- advances in therapeutic engineering, CRC Press, Taylor and Francis Group, ISBN:978-1-4398-7173-7, pp 215–266 (Chapter 11)
Gersh BJ, Sliwa K, Mayosi BM, Yusuf S (2010) Novel therapeutic concepts: the epidemic of cardiovascular disease in the developing world: global implications. Eur Heart J 31(6):642–648
Logmani L, Jariani AL, Borhani F (2006) Effect of preoperative instruction on postoperative depression in patients undergoing open heart surgery. Daneshvar pezeshki 14(67):33–42. [Persion]
McAlister FA, Man J, Bistritz L, Amad H, Tandon P (2003) Diabetes and coronary artery bypass surgery: an examination of perioperative glycemic control and outcomes. Diabetes Care 26:1518–1524
Padmanaban P, Toora B (2011) Hemoglobin: emerging marker in stable coronary artery disease. Chron Young Sci 2(2):109. doi:10.4103/2229-5186.82971
Handin RI, Lux SE, Stossel B, Thomas PB (2003) Principles and practice of hematology. Lippincott Williams and Wilkins. ISBN:0781719933
Minic Z, Hervé G (2004) Biochemical and enzymological aspects of the symbiosis between the deep-sea tubeworm Riftia pachyptila and its bacterial endosymbiont. Eur J Biochem 271(15):3093–3102. doi:10.1111/j.1432-1033.2004.04248.x. PMID 15265029
Newton DA, Rao KM, Dluhy RA, Baatz JE (2006) Hemoglobin is expressed by alveolar epithelial cells. J Biol Chem 281(9):5668–5676. doi:10.1074/jbc.M509314200. PMID 16407281
Marik PE, Corwin HL (2008) Efficacy of red blood cell transfusion in the critically ill: a systematic review of the literature. Crit Care Med 36:2667–2674
Charles P, Elliot P (1995) Handbook of biological effects of electromagnetic fields. CRC Press, New York
Sang V (2010) The use of the mechanical fragility test in evaluating sublethal RBC injury during storage 99(4):325–331
Sadhu PK, Mukherjee SK, Chakrabarti RN, Chowdhury SP, Karan BM, Gupta RK, Reddy CVSC (2002) High efficient contamination free clean heat production. Indian J Eng Mater Sci 9:172–176
Sadhu PK, Pal N, Bhattacharya A (2013) Design of working coil using Litz Wire for industrial induction heater. Lap Lambert Academic Publishing, ISBN:978-3-659 -35853-1, pp 1–65
Inayathullaah MA, Anita R et al (2010) Single phase high frequency Ac converter for induction heating application. Int J Eng Sci Technol 2(12):7191–7197
Kotsuka Y, Hankui E, Shigematsu E (1996) Development of ferrite core applicator system for deep-induction Hyperthermia. IEEE Trans Microw Theor Tech 44(10):1803–1810
Chen H, Ikeda-Saito M, Shaik S (2008) Nature of the Fe-O2 bonding in oxy-myoglobin: effect of the protein. J Am Chem Soc 130(44):14778–14790. doi:10.1021/ja805434m. PMID 18847206
Hohn L, Schweizer A, Kalangos A et al (1998) Benefits of intraoperative skin surface warming in cardiac surgical patients. Br J Anaesth 80:318–323
Kotsuka Y et al (2000) Development of inductive regional heating system for breast Hyperthermia. IEEE Trans Microw Theor Tech 48(2):1807, 1813
Burdio JM, Fernando M, Garcia JR, Barragan LA, Abelardo M (2005) A two-output series-resonant inverter for induction-heating cooking appliances. IEEE Trans Power Electron 20(4):815–822
Rajek A, Lenhardt R, Sessler DI et al (1998) Tissue heat content and distribution during and after cardiopulmonary bypass at 31 °C and 27 °C. Anesthesiology 88:1511–1518
Acknowledgments
Authors are thankful to the UNIVERSITY GRANTS COMMISSION, Bahadurshah Zafar Marg, New Delhi, India for granting financial support under Major Research Project entitled “Simulation of high-frequency mirror inverter for energy efficient induction heated cooking oven” and also grateful to the Under Secretary and Joint Secretary of UGC, India for their active co-operation.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer India
About this paper
Cite this paper
Pal, P., Sadhu, P.K., Pal, N., Bhowmik, P. (2015). A New Heat Treatment Topology for Reheating of Blood Tissues After Open Heart Surgery. In: Gupta, S., Bag, S., Ganguly, K., Sarkar, I., Biswas, P. (eds) Advancements of Medical Electronics. Lecture Notes in Bioengineering. Springer, New Delhi. https://doi.org/10.1007/978-81-322-2256-9_10
Download citation
DOI: https://doi.org/10.1007/978-81-322-2256-9_10
Published:
Publisher Name: Springer, New Delhi
Print ISBN: 978-81-322-2255-2
Online ISBN: 978-81-322-2256-9
eBook Packages: EngineeringEngineering (R0)