Skip to main content

Abstract

There have been significant advancements in continuous-flow left ventricular assist device s over the past few years, but new devices are still needed to improve the quality of life of patients with advanced heart failure and reduce adverse events. In this chapter we describe a fully magnetically levitated left ventricular assist device (HeartMate III), a fully implanted left ventricular assist system with the percutaneous driveline replaced by a wireless energy transmission system for tether-free support (FILVAS), an ultraminiaturized VAD (the HeartMate X) for left, right, or biventricular support, and a new percutaneous heart pump (HeartMate PHP) to address needs for patients needing short-term hemodynamic support.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Notes

  1. 1.

    All devices in this chapter are in development and not in clinical use as of June 2013.

References

  1. Starling RC, Naka Y, Boyle AJ, Gonzalez-Stawinski G, John R, Jorde U, Russell SD, Conte JV, Aaronson KD, McGee Jr EC, Cotts WG, DeNofrio D, Pham DT, Farrar DJ, Pagani FD. Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: a prospective study using INTERMACS. J Am Coll Cardiol. 2011;57(19):1890–8.

    Article  PubMed  Google Scholar 

  2. John R, Naka Y, Smedira NG, Starling R, Jorde U, Eckman P, Farrar DJ, Pagani FD. Continuous flow left ventricular assist device outcomes in commercial use compared with the prior clinical trial. Ann Thorac Surg. 2011;92:1406–13.

    Article  PubMed  Google Scholar 

  3. Kirklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Baldwin JT, Young JB. Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patients. J Heart Lung Transplant. 2013;32:141–56.

    Article  PubMed  Google Scholar 

  4. Park SJ, Milano CA, Tatooles AJ, Rogers JG, Adamson RM, Steidley DE, Ewald GA, Sundareswaran KS, Farrar DJ, Slaughter MS. Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy. Circ Heart Fail. 2012;5:241–8.

    Article  PubMed  Google Scholar 

  5. Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361:2241–51.

    Article  PubMed  CAS  Google Scholar 

  6. Bourque K, Dague C, Farrar D, Harms K, Tamez D, Cohn W, Tuzun E, Poirier V, Frazier OH. In vivo assessment of a rotary left ventricular assist device-induced artificial pulse in the proximal and distal aorta. Artif Organs. 2007;30(8):638–42.

    Article  Google Scholar 

  7. Farrar DJ, Bourque K, Dague CP, Cotter CJ, Poirier VL. Design features, developmental status, and experimental results with the Heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor. ASAIO J. 2007;53(3):310–5.

    Article  PubMed  Google Scholar 

  8. Dowling RD, Gray Jr LA, Etoch SW, Laks H, Marelli D, Samuels L, Entwistle J, Couper G, Vlahakes GJ, Frazier OH. Initial experience with the AbioCor implantable replacement heart system. J Thorac Cardiovasc Surg. 2004;127(1):131–41.

    Article  PubMed  Google Scholar 

  9. Pae WE, Connell JM, Adelowo A, Boehmer JP, Korfer R, El-Banayosy HR, Vigano M, Pavie A. Does total implantability reduce infection with the use of a left ventricular assist device? The lionheart experience in Europe. J Heart Lung Transplant. 2007;26:219–29.

    Article  PubMed  Google Scholar 

  10. Sundareswaran KS, Reichenbach SH, Masterson KB, Butler KC, Farrar DJ. Low bearing wear in explanted HeartMate II left ventricular assist devices after chronic clinical support. ASAIO J. 2013;59(1):41–5.

    Article  PubMed  Google Scholar 

  11. Karalis A, Joannopoulos JD, Soljacic M. Efficient wireless non-radiative mid-range energy transfer. Ann Phys. 2008;323:34–48.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to David J. Farrar .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer Japan

About this chapter

Cite this chapter

Farrar, D.J., Bourque, K., Reichenbach, S.H., Muller, P., Peri, L. (2014). Innovation Update. In: Kyo, S. (eds) Ventricular Assist Devices in Advanced-Stage Heart Failure. Springer, Tokyo. https://doi.org/10.1007/978-4-431-54466-1_8

Download citation

  • DOI: https://doi.org/10.1007/978-4-431-54466-1_8

  • Published:

  • Publisher Name: Springer, Tokyo

  • Print ISBN: 978-4-431-54465-4

  • Online ISBN: 978-4-431-54466-1

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics