Modified Palatal Plate

  • Chapter
  • First Online:
Temporary Skeletal Anchorage Devices

Abstract

Distalization appliances supported by temporary skeletal anchorage devices (TSADs) have been proposed. In this chapter, we have introduced the modified palatal anchorage plate (MPAP) appliance for maxillary arch distalization, its clinical relevance, indications, complications, and treatment outcome. The quality and the quantity of the paramedian palatal bony structure can mechanically support several mini-implants in both adults and adolescents. The design of the palatal plate has been modified for easier and more accurate placement and less inflammation to the tissues. Clinically successful distalization was achieved in 11.6 ± 4.3 months. The maxillary first molar showed 3.70 mm of distalization, 3.29° of distal tipping, and 2.40 mm of intrusion. Therefore, the palatal plate might be recommended for maxillary molar distalization in adults and adolescents.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 129.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Fields HW, Proffit WR. Treatment of skeletal problems in children and preadolescents. In: Proffit WR, Fields HW, Sarver DM, editors. Contemporary orthodontics. 5th ed. St. Louis: Mosby Elsevier; 2013. p. 507.

    Google Scholar 

  2. Bolla E, Muratore F, Carano A, Bowman SJ. Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods. Angle Orthod. 2002;72(5):481–94. PubMed PMID: 12401059. Epub 2002/10/29. eng.

    PubMed  Google Scholar 

  3. Bussick TJ, McNamara Jr JA. Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofacial Orthop. 2000;117(3):333–43. PubMed PMID: 10715093. Epub 2000/03/14. eng.

    Article  PubMed  Google Scholar 

  4. Chiu PP, McNamara Jr JA, Franchi L. A comparison of two intraoral molar distalization appliances: distal jet versus pendulum. Am J Orthod Dentofacial Orthop. 2005;128(3):353–65. PubMed PMID: 16168332. Epub 2005/09/20. eng.

    Article  PubMed  Google Scholar 

  5. Ghosh J, Nanda RS. Evaluation of an intraoral maxillary molar distalization technique. Am J Orthod Dentofacial Orthop. 1996;110(6):639–46. PubMed PMID: 8972811. Epub 1996/12/01. eng.

    Article  PubMed  Google Scholar 

  6. Muse DS, Fillman MJ, Emmerson WJ, Mitchell RD. Molar and incisor changes with Wilson rapid molar distalization. Am J Orthod Dentofacial Orthop. 1993;104(6):556–65. PubMed PMID: 8249931. Epub 1993/12/01. eng.

    Article  PubMed  Google Scholar 

  7. Keles A, Sayinsu K. A new approach in maxillary molar distalization: intraoral bodily molar distalizer. Am J Orthod Dentofacial Orthop. 2000;117(1):39–48. PubMed PMID: 10629518.

    Article  PubMed  Google Scholar 

  8. Kinzinger GS, Eren M, Diedrich PR. Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalization: a literature review. Eur J Orthod. 2008;30(6):558–71. PubMed PMID: 18820306.

    Article  PubMed  Google Scholar 

  9. Fontana M, Cozzani M, Caprioglio A. Soft tissue, skeletal and dentoalveolar changes following conventional anchorage molar distalization therapy in class II non-growing subjects: a multicentric retrospective study. Prog Orthod. 2012;13(1):30–41. PubMed PMID: 22583585.

    Article  PubMed  Google Scholar 

  10. Ishida T, Yoon HS, Ono T. Asymmetrical distalization of maxillary molars with zygomatic anchorage, improved superelastic nickel-titanium alloy wires, and open-coil springs. Am J Orthod Dentofacial Orthop. 2013;144(4):583–93. PubMed PMID: 24075667.

    Article  PubMed  Google Scholar 

  11. Kaya B, Sar C, Arman-Ozcirpici A, Polat-Ozsoy O. Palatal implant versus zygoma plate anchorage for distalization of maxillary posterior teeth. Eur J Orthod. 2013;35(4):507–14. PubMed PMID: 22968670.

    Article  PubMed  Google Scholar 

  12. Kook YA, Kim SH, Chung KR. A modified palatal anchorage plate for simple and efficient distalization. J Clin Orthod. 2010;44(12):719–30, quiz 43. PubMed PMID: 21591548.

    PubMed  Google Scholar 

  13. Kook YA, Lee DH, Kim SH, Chung KR. Design improvements in the modified C-palatal plate for molar distalization. J Clin Orthod. 2013;47(4):241–8, quiz 67–8. PubMed PMID: 23660818.

    PubMed  Google Scholar 

  14. Ludwig B, Glasl B, Kinzinger GS, Walde KC, Lisson JA. The skeletal frog appliance for maxillary molar distalization. J Clin Orthod. 2011;45(2):77–84, quiz 91. PubMed PMID: 21710878.

    PubMed  Google Scholar 

  15. Sar C, Kaya B, Ozsoy O, Ozcirpici AA. Comparison of two implant-supported molar distalization systems. Angle Orthod. 2013;83(3):460–7. PubMed PMID: 23106546.

    Article  PubMed  Google Scholar 

  16. Valiyaparambil JV, Yamany I, Ortiz D, Shafer DM, Pendrys D, Freilich M, et al. Bone quality evaluation: comparison of cone beam computed tomography and subjective surgical assessment. Int J Oral Maxillofac Implants. 2012;27(5):1271–7. PubMed PMID: 23057044.

    PubMed  Google Scholar 

  17. Parsa A, Ibrahim N, Hassan B, Motroni A, van der Stelt P, Wismeijer D. Influence of cone beam CT scanning parameters on grey value measurements at an implant site. Dentomaxillofac Radiol. 2013;42(3):79884780. PubMed PMID: 22933535. Pubmed Central PMCID: 3667541.

    Article  PubMed Central  PubMed  Google Scholar 

  18. Kaya S, Yavuz I, Uysal I, Akkus Z. Measuring bone density in healing periapical lesions by using cone beam computed tomography: a clinical investigation. J Endod. 2012;38(1):28–31. PubMed PMID: 22152615.

    Article  PubMed  Google Scholar 

  19. Fuster-Torres MA, Penarrocha-Diago M, Penarrocha-Oltra D, Penarrocha-Diago M. Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study. Int J Oral Maxillofac Implants. 2011;26(5):1051–6. PubMed PMID: 22010089.

    PubMed  Google Scholar 

  20. Moon SH, Park SH, Lim WH, Chun YS. Palatal bone density in adult subjects: implications for mini-implant placement. Angle Orthod. 2010;80(1):137–44. PubMed PMID: 19852653. Epub 2009/10/27. eng.

    Article  PubMed  Google Scholar 

  21. Han S, Bayome M, Lee J, Lee YJ, Song HH, Kook YA. Evaluation of palatal bone density in adults and adolescents for application of skeletal anchorage devices. Angle Orthod. 2012;82(4):625–31. PubMed PMID: 22077190.

    Article  PubMed  Google Scholar 

  22. Misch CE. Density of bone: effect on treatment plans, surgical approach, healing, and progressive boen loading. Int J Oral Implantol. 1990;6(2):23–31. PubMed PMID: 2073394. Epub 1990/01/01. eng.

    PubMed  Google Scholar 

  23. Bernhart T, Vollgruber A, Gahleitner A, Dortbudak O, Haas R. Alternative to the median region of the palate for placement of an orthodontic implant. Clin Oral Implants Res. 2000;11(6):595–601. PubMed PMID: 11168253. Epub 2001/02/13. eng.

    Article  PubMed  Google Scholar 

  24. Wehrbein H. Bone quality in the midpalate for temporary anchorage devices. Clin Oral Implants Res. 2009;20(1):45–9. PubMed PMID: 19126107. Epub 2009/01/08. eng.

    Article  PubMed  Google Scholar 

  25. Crismani AG, Bernhart T, Schwarz K, Celar AG, Bantleon HP, Watzek G. Ninety percent success in palatal implants loaded 1 week after placement: a clinical evaluation by resonance frequency analysis. Clin Oral Implants Res. 2006;17(4):445–50. PubMed PMID: 16907777. Epub 2006/08/16. eng.

    Article  PubMed  Google Scholar 

  26. Wehrbein H, Feifel H, Diedrich P. Palatal implant anchorage reinforcement of posterior teeth: a prospective study. Am J Orthod Dentofacial Orthop. 1999;116(6):678–86. PubMed PMID: 10587603. Epub 1999/12/10. eng.

    Article  PubMed  Google Scholar 

  27. Deguchi T, Nasu M, Murakami K, Yabuuchi T, Kamioka H, Takano-Yamamoto T. Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants. Am J Orthod Dentofacial Orthop. 2006;129(6):721.e7–12. PubMed PMID: 16769488. Epub 2006/06/14. eng.

    Article  Google Scholar 

  28. Kang S, Lee SJ, Ahn SJ, Heo MS, Kim TW. Bone thickness of the palate for orthodontic mini-implant anchorage in adults. Am J Orthod Dentofacial Orthop. 2007;131(4 Suppl):S74–81. PubMed PMID: 17448390. Epub 2007/04/24. eng.

    Article  PubMed  Google Scholar 

  29. King KS, Lam EW, Faulkner MG, Heo G, Major PW. Vertical bone volume in the paramedian palate of adolescents: a computed tomography study. Am J Orthod Dentofacial Orthop. 2007;132(6):783–8. PubMed PMID: 18068597. Epub 2007/12/11. eng.

    Article  PubMed  Google Scholar 

  30. Stockmann P, Schlegel KA, Srour S, Neukam FW, Fenner M, Felszeghy E. Which region of the median palate is a suitable location of temporary orthodontic anchorage devices? A histomorphometric study on human cadavers aged 15–20 years. Clin Oral Implants Res. 2009;20(3):306–12. PubMed PMID: 19397643. Epub 2009/04/29. eng.

    Article  PubMed  Google Scholar 

  31. Gracco A, Lombardo L, Cozzani M, Siciliani G. Quantitative cone-beam computed tomography evaluation of palatal bone thickness for orthodontic miniscrew placement. Am J Orthod Dentofacial Orthop. 2008;134(3):361–9. PubMed PMID: 18774082. Epub 2008/09/09. eng.

    Article  PubMed  Google Scholar 

  32. Ryu JH, Park JH, Vu Thi Thu T, Bayome M, Kim Y, Kook YA. Palatal bone thickness compared with cone-beam computed tomography in adolescents and adults for mini-implant placement. Am J Orthod Dentofacial Orthop. 2012;142(2):207–12. PubMed PMID: 22858330.

    Article  PubMed  Google Scholar 

  33. Melsen B. Palatal growth studied on human autopsy material. A histologic microradiographic study. Am J Orthod. 1975;68(1):42–54. PubMed PMID: 1056143. Epub 1975/07/01. eng.

    Article  PubMed  Google Scholar 

  34. Revelo B, Fishman LS. Maturational evaluation of ossification of the midpalatal suture. Am J Orthod Dentofacial Orthop. 1994;105(3):288–92. PubMed PMID: 8135215. Epub 1994/03/01. eng.

    Article  PubMed  Google Scholar 

  35. Schlegel KA, Kinner F, Schlegel KD. The anatomic basis for palatal implants in orthodontics. Int J Adult Orthodon Orthognath Surg. 2002;17(2):133–9. PubMed PMID: 12099317. Epub 2002/07/09. eng.

    PubMed  Google Scholar 

  36. Wehrbein H, Merz BR, Diedrich P, Glatzmaier J. The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem. Clin Oral Implants Res. 1996;7:410–6.

    Article  PubMed  Google Scholar 

  37. Bernhart T, Freudenthaler J, Dortbudak O, Bantleon HP, Watzek G. Short epithetic implants for orthodontic anchorage in the paramedian region of the palate. A clinical study. Clin Oral Implants Res. 2001;12(6):624–31. PubMed PMID: 11737107. Epub 2001/12/12. eng.

    Article  PubMed  Google Scholar 

  38. Gracco A, Lombardo L, Cozzani M, Siciliani G. Quantitative evaluation with CBCT of palatal bone thickness in growing patients. Prog Orthod. 2006;7(2):164–74. PubMed PMID: 17143344. Epub 2006/12/05. Eng. ita.

    PubMed  Google Scholar 

  39. Tosun T, Keles A, Erverdi N. Method for the placement of palatal implants. Int J Oral Maxillofac Implants. 2002;17(1):95–100. PubMed PMID: 11858579. Epub 2002/02/23. eng.

    PubMed  Google Scholar 

  40. Enlow DH, Hans MG. Essentials of facial growth. Philadelphia: Saunders; 1996. p. 79–98.

    Google Scholar 

  41. Wara-aswapati N, Pitiphat W, Chandrapho N, Rattanayatikul C, Karimbux N. Thickness of palatal masticatory mucosa associated with age. J Periodontol. 2001;72(10):1407–12. PubMed PMID: 11699483.

    Article  PubMed  Google Scholar 

  42. Poggio PM, Incorvati C, Velo S, Carano A. “Safe zones”: a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod. 2006;76(2):191–7. PubMed PMID: 16539541.

    PubMed  Google Scholar 

  43. Januario AL, Barriviera M, Duarte WR. Soft tissue cone-beam computed tomography: a novel method for the measurement of gingival tissue and the dimensions of the dentogingival unit. J Esthet Restor Dent. 2008;20(6):366–73; discussion 74. PubMed PMID: 19120781.

    Article  PubMed  Google Scholar 

  44. Barriviera M, Duarte WR, Januario AL, Faber J, Bezerra AC. A new method to assess and measure palatal masticatory mucosa by cone-beam computerized tomography. J Clin Periodontol. 2009;36(7):564–8. PubMed PMID: 19538329.

    Article  PubMed  Google Scholar 

  45. Song JE, Um YJ, Kim CS, Choi SH, Cho KS, Kim CK, et al. Thickness of posterior palatal masticatory mucosa: the use of computerized tomography. J Periodontol. 2008;79(3):406–12. PubMed PMID: 18315422.

    Article  PubMed  Google Scholar 

  46. Ueno D, Sato J, Igarashi C, Ikeda S, Morita M, Shimoda S, et al. Accuracy of oral mucosal thickness measurements using spiral computed tomography. J Periodontol. 2011;82(6):829–36. PubMed PMID: 21073331.

    Article  PubMed  Google Scholar 

  47. Lost C, Irion KM, Nussle W. Ultrasonic B-scans of the facial/oral periodontium in pigs. J Clin Periodontol. 1989;16(8):534–8. PubMed PMID: 2674205.

    Article  PubMed  Google Scholar 

  48. Uchida H, Kobayashi K, Nagao M. Measurement in vivo of masticatory mucosal thickness with 20 MHz B-mode ultrasonic diagnostic equipment. J Dent Res. 1989;68(2):95–100. PubMed PMID: 2645334.

    Article  PubMed  Google Scholar 

  49. Eger T, Muller HP, Heinecke A. Ultrasonic determination of gingival thickness. Subject variation and influence of tooth type and clinical features. J Clin Periodontol. 1996;23(9):839–45. PubMed PMID: 8891935.

    Article  PubMed  Google Scholar 

  50. Studer SP, Allen EP, Rees TC, Kouba A. The thickness of masticatory mucosa in the human hard palate and tuberosity as potential donor sites for ridge augmentation procedures. J Periodontol. 1997;68(2):145–51. PubMed PMID: 9058332.

    Article  PubMed  Google Scholar 

  51. Muller HP, Schaller N, Eger T. Ultrasonic determination of thickness of masticatory mucosa: a methodologic study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1999;88(2):248–53. PubMed PMID: 10468471.

    Article  PubMed  Google Scholar 

  52. Muller HP, Heinecke A, Schaller N, Eger T. Masticatory mucosa in subjects with different periodontal phenotypes. J Clin Periodontol. 2000;27(9):621–6. PubMed PMID: 10983595.

    Article  PubMed  Google Scholar 

  53. Muller HP, Schaller N, Eger T, Heinecke A. Thickness of masticatory mucosa. J Clin Periodontol. 2000;27(6):431–6. PubMed PMID: 10883873.

    Article  PubMed  Google Scholar 

  54. Schulze RK, Curic D, D’Hoedt B. B-mode versus A-mode ultrasonographic measurements of mucosal thickness in vivo. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002;93(1):110–7. PubMed PMID: 11805786.

    Article  PubMed  Google Scholar 

  55. Kim HJ, Yun HS, Park HD, Kim DH, Park YC. Soft-tissue and cortical-bone thickness at orthodontic implant sites. Am J Orthod Dentofacial Orthop. 2006;130(2):177–82. PubMed PMID: 16905061.

    Article  PubMed  Google Scholar 

  56. Lee SM, Park JH, Bayome M, Kim HS, Mo SS, Kook YA. Palatal soft tissue thickness at different ages using an ultrasonic device. J Clin Pediatr Dent. 2012;36(4):405–9. PubMed PMID: 23019841.

    PubMed  Google Scholar 

  57. Gedrange T, Mai R, Mack F, Zietek M, Borsos G, Vegh A, et al. Evaluation of shape and size changes of bone and remodelled bone substitute after different fixation methods. J Physiol Pharmacol. 2008;59 Suppl 5:87–94. PubMed PMID: 19075329.

    PubMed  Google Scholar 

  58. Moelans CB, ter Hoeve N, van Ginkel JW, ten Kate FJ, van Diest PJ. Formaldehyde substitute fixatives. Analysis of macroscopy, morphologic analysis, and immunohistochemical analysis. Am J Clin Pathol. 2011;136(4):548–56.

    Article  PubMed  Google Scholar 

  59. Vu T, Bayome M, Kook YA, Han SH. Evaluation of the palatal soft tissue thickness by cone-beam computed tomography. Korean J Orthod. 2012;42(6):291–6. PubMed PMID: 23323243. Pubmed Central PMCID: 3542449.

    Article  PubMed Central  PubMed  Google Scholar 

  60. Cha BK, Lee YH, Lee NK, Choi DS, Baek SH. Soft tissue thickness for placement of an orthodontic miniscrew using an ultrasonic device. Angle Orthod. 2008;78(3):403–8. PubMed PMID: 18416626.

    Article  PubMed  Google Scholar 

  61. Joo MC. Evaluation of palatal plate effects on the speech articulation using acoustic analysis [Master]. Seoul: The Catholic University of Korea; 2012.

    Google Scholar 

  62. Kook YA, Bayome M, Trang VT, Kim HJ, Park JH, Kim KB, et al. Evaluation of treatment effects of a modified palatal anchorage plate for distalization using CBCT. Am J Orthod Dentofacial Orthop. In press.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoon-Ah Kook DDS, PhD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Kook, YA., Bayome, M., Mo, SS., Kim, Y., Chung, KR. (2014). Modified Palatal Plate. In: Kim, K. (eds) Temporary Skeletal Anchorage Devices. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-55052-2_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-55052-2_5

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-55051-5

  • Online ISBN: 978-3-642-55052-2

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics