Abstract
Energy efficiency is one of the topics in achieving the goal of reducing the CO2 output in the next years. Data centers (DC) are big polluters. GreenIT DC-Benchmarking is the first neutral benchmarking tool that shows the specific energy and cost saving potential in data centers. By comparison with similar data centers and analysis of best practices, IT managers gain a detailed overview of ways to optimize their systems. The online based comparison tool can be applied to data centers of any type and size. The basic set of data for the GreenIT DC-Benchmarking deviates from a scientific analysis of thirty data centers realized by the Technical University of Berlin. Since April 2010, the stock in the benchmarking tool has grown to 108 data center with more than 79,000 servers.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
The German Federal Ministry of Economics and Technology: Action plan “Germany: Green IT Pioneer”, p. 2 (2008), http://www.bmwi.de/English/Redaktion/Pdf/action-plan-green-it-pioneer,property=pdf,bereich=bmwi,sprache=en,rwb=true.pdf
Borderstep Insitute: Energyefficient Data Centers – Best-Practice-Examples from Europe, USA and Asia, Berlin, p. 8 (2008), http://www.borderstep.de/pdf/P-Fichter-Clausen-Eimertenbrink-Energy-Efficient_Data_Centres-Best-Practice_Examples_from_Europa_USA_and_Asia-2008.pdf
Prof. Dr. rer. Nat. Frank Behrendt, et al.: Konzeptstudie zur Energie- und Ressourceneffizienz im Betrieb von Rechenzentren; TU Berlin, Innovation Centre Energy (IZE) (December 2008) partly financed by TSB Technologiestiftung Berlin http://www.energie.tu-berlin.de/uploads/media/IZE_Konzeptstudie_Energieeffizienz_in_Rechenzentren.pdf ; Main results: The increase in the average server room temperature in conjunction with the increase in the chiller temperature and indirect free cooling helps a lot. With little investment in the building infrastructure greatest savings can be realized. But also for the implementation of pioneering concepts such as combined heat-power-refrigeration (trigeneration) of data centers by district heating are often very good conditions, p. 137
Study by Experton Group (2009), http://images.computerwoche.de/images/computerwoche/bdb/493837/C9FE99D05B6E2AB7257C811737B07F55_800x600.jpg (stated June 26, 2009)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Israel, Y., Leitert, T. (2012). The GreenIT DC-Benchmarking Tool: From Scientific Theory to Real Life. In: Huusko, J., de Meer, H., Klingert, S., Somov, A. (eds) Energy Efficient Data Centers. E2DC 2012. Lecture Notes in Computer Science, vol 7396. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-33645-4_5
Download citation
DOI: https://doi.org/10.1007/978-3-642-33645-4_5
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-33644-7
Online ISBN: 978-3-642-33645-4
eBook Packages: Computer ScienceComputer Science (R0)