Abstract
The main reason for the deterioration of electrical equipment insulation is the high- voltage discharge. So, real-time monitoring of electrical equipment discharge is the key to ensure the safe operation of equipment. Using the UV signal in solar blind area as characteristic parameter, this paper designs the Optical Fiber Sensor and analyze its spectral response characteristics. The lens coupling system is designed to improve the detection of light coupling efficiency. The efficiency is improved by the simulation and optimization of ZEMAX. Simulation detecting tests on needle plate discharge is carried out in the laboratory, and it presents that the detection system can accurately detect the UV radiation of the discharge and the strength of the discharge to linear response. The detection system has high sensitivity, and strong anti-interference. It can be used for online real-time monitoring of high voltage discharge.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Yan, Z., Zhu, D.: Technology of high-voltage insulation. China Electric Power Press, Beijing (2007)
Wu, G.: Theory and practice of state testing to electrical equipment. Tsinghua University Press, Beijing (2005)
Zhang, J.: Technology and application of UV detection to high-voltage discharge. China Electric Power Press, Beijing (2009)
Guo, J., Wu, G., Zhang, X.: Current situation and development of partial discharge detection technology. J. Electrotechnical Society 2(20), 29–34 (2005)
Xu, Y., Yu, M., Cao, X.: Comparison with light pulse method and the electrometric method of partial discharge. J. High Voltage Engineering 27(4), 3–5 (2001)
Si, W., Li, j., Yuan, P.: Research situation and development of optical detection method to partial discharge. J. high-voltage electrical appliances 44(3), 261–264 (2008)
Chen, X., Jiang, Y.: Comparative study on two ultra-wideband detection technique of partial discharge. J. High Voltage Engineering 27(6), 6–8 (2001)
Dai, L.: Appication of UV imaging technology on high-voltage discharge detection. J. Power Systems 27(20), 97–98 (2003)
Li, Q., Chen, T., Wang, J.: Application of UV Pulse Method on the UHV Discharge Detection. High Voltage Engineering 32(12), 26–29 (2006)
Zhang, Z., Wang, K., Tang, J.: Detection Method for Corona Discharge of Transformers on Ultraviolet Pulse. J. Power Systems 2(34), 84–88 (2010)
Yin, Z., Fang, D., Xuechen, L.: Optical method in micro-DBD discharge characteristics. J. Spectroscopy and Spectral Analysis. 23(3), 607–608 (2003)
Zhao, W., Zhang, X., Jiang, J.: Spectral Analysis of corona discharge to tip plate. J.Spectroscopy and Spectral Analysis 23(5), 9,552,957 (2003)
Wang, W., Liu, D., Wu, Y.: Spectral Analysis on reactor distribution of high energy electron density along Air corona discharge. J. Molecular Science 15(3), 1,252,128 (1999)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Xu, Y., Chen, H. (2011). Study on UV Detection of High-Voltage Discharge Based on the Optical Fiber Sensor. In: Wan, X. (eds) Electrical Power Systems and Computers. Lecture Notes in Electrical Engineering, vol 99. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21747-0_3
Download citation
DOI: https://doi.org/10.1007/978-3-642-21747-0_3
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-21746-3
Online ISBN: 978-3-642-21747-0
eBook Packages: EngineeringEngineering (R0)