The purpose of this study was to survey image quality and the entrance surface air kerma for patients in radiographic examinations and to perform comparisons with diagnostic reference levels. In this study, image quality and patient radiation doses were surveyed in 50 hospitals from different proviences in Iran. The rate of unsatisfactory images and image quality grade were noted, and causes for poor image quality were investigated. The entrance surface doses for adult patients were determined in terms of the entrance surface air kerma on the basis of X-ray tube output measurements and X-ray exposure parameters. Comparison of dose levels with diagnostic reference levels was performed. The image quality improved up to 10 percentage points in different hospitals after implementation of a quality control (QC) program. Patient doses varied by a factor of up to 22, although the majority of doses were below diagnostic reference levels. The mean entrance surface air kerma values in mGy before QC were 0.48 (chest, posterior-anterior), 3.4 (lumbar spine, anterior- posterior(AP)), 8.81 (lumbar spine, lateral), 3.56 (abdomen, AP), 2.79 (pelvis, AP), 2.27 (skull, AP) and 1.5 (skull , lateral) and after QC were 0.37 (chest, AP), 3.13 (lumbar spine,AP), 7.56 (lumbar spine, lateral), 3.34 (abdomen, AP), 2.71 (pelvis, AP), 2.1 (skull, AP) and 1.43 (skull , lateral) . Patient doses were found to be similar to doses in developed countries and patient dose reductions ranging from 3% to 23% were achieved. Comparison with other surveys indicates that patient dose levels in these hospitals are not higher than those in developed countries.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Deevband, M.R., KeykhaFarzaneh, M.J., Kardan, M.R., Khosravi, H.R., Faghihi, F., Faghihi, R. (2009). Patient Dose Reduction in Some Routine Radiographic Examination in Iran. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/3. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03902-7_30

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03902-7_30

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03901-0

  • Online ISBN: 978-3-642-03902-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics