Abstract
The purpose of this study was to investigate the effect of light curing tip angulations on the shear bond strength of an orthodontic adhesive. Three groups of thirty premolar teeth had brackets attached in a standardized manner using Transbond XT. The orthodontic adhesive were cured with a Blue LED light curing unit for 40 seconds using three different angulations 0°, 45° and 90° at a standardized 3 mm distance. The debonding force was measured using an Instron Universal Testing Machine. Data were computed and analysed using SPSS version 12.0. Kruskal-Wallis test was employed to compare the shear bond strength of all groups. The study found that there was no significant difference on the shear bond strengths of orthodontic adhesive when cured at the angulations of light curing tip of 0°, 45° and 90°.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Powers JM., Sakaguchi RL. Craig’s Restorative Dental Materials. Philadelphia. Mosby Elservier. 2006
McCabe JF, Walls AWG. Applied Dental Materials. 8th Edition. Blackwell Publishing. 1998
Van Noort, R. Introductions to Dental Materials. Third Edition. Mosby-Year Book, Inc. 2007.
Kelsey WP, Shearer GO, Cavel WT, Blankenau RJ. The effects of wand positioning on the polymerization of composite resin. J Am Dent Assoc. 1987;114:213–215
Radzi, Z., Yahya, N. A., Zamzam, N., Wood, D.J., (2004) Light Curing Units in Orthodontics. Annals of Dentistry 11: 13–23
Caldas DB, de Almeida JB, Correr-Sobrinho L, Sinhoreti MA, Consani S. Influence of curing tip distance on resin composite Knoop hardness number, using three different light curing units. Oper Dent. 2003; 28:315–320.
Rueggeberg FA, Jordan DM. Effect of light-tip distance on polymerization of resin composite. Int J Prosthodont. 1993; 6:364–370.
Meyer GR, Ernst CP, Willershausen B. Decrease in power output of new light-emitting diode (LED) curing devices with increasing distance to filling surface. J Adhes Dent. 2002; 4:197–204.
Cacciafesta, V., Sfondrini M.F., Scribante, A., Jost-Brinkmann, P.G.. Effect of light-tip distance on the shear bond strength of composite resin. Angle Orthod. 2005; 75: 386–391
Radzi Z, Kasim NHA, Yahya NA, Abu Osman NA, Kassim NL. Standardization Of Distance And Angulation Of Light Curing Unit Tip Using Distometer. International Federation for Medical and Biological Engineering. Springer-Verlag 2006; 15: 136–138
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Yusoff, U.A., Radzi, Z., Abu Kasim, N.H., Yahya, N.A., Abu Osman, N.A. (2008). The Effect of Light Curing Tip Angulations on the Shear Bond Strength of an Orthodontic Adhesive. In: Abu Osman, N.A., Ibrahim, F., Wan Abas, W.A.B., Abdul Rahman, H.S., Ting, HN. (eds) 4th Kuala Lumpur International Conference on Biomedical Engineering 2008. IFMBE Proceedings, vol 21. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-69139-6_90
Download citation
DOI: https://doi.org/10.1007/978-3-540-69139-6_90
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-69138-9
Online ISBN: 978-3-540-69139-6
eBook Packages: EngineeringEngineering (R0)