Abstract
The purpose of the present chapter is to review the most recent advances in real-time transthoracic and transesophageal three-dimensional echocardiography. The method has been shown to be feasible, accurate, and useful in several pathologies, allowing several advantages over the traditional 2D imaging particularly in valve diseases, cardiac masses, quantification of left and right ventricular volumes, and procedural monitoring, including cardiac surgery.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Suggested Reading
Flachskampf FA, Wouters PF, Edvardsen T, Evangelista A, Habib G, Hoffman P, Hoffmann R, Lancellotti P, Pepi M, for the European Association of Cardiovascular Imaging. Recommendations for transoesophageal echocardiography: EACVI update 2014. Eur Heart J Cardiovasc Imaging. 2014;5(4):353–65.
Gripari P, Tamborini G, Barbier P, Maltagliati A, Galli C, Muratori M, Salvi L, Sisillo E, Alamanni F, Pepi M. Real-time three-dimensional transoesophageal echocardiography: a new intraoperative feasible and useful technology in cardiac surgery. Int J Cardiovasc Imaging. 2010;26:651–60.
Lang RM, Badano LP, Tsang W, Adams DH, Agricola E, Buck T, Faletra FF, Franke A, Hung J, Pérez de Isla L, Kamp O, Kasprzak JD, Lancellotti P, Marwick TH, McCulloch ML, Monaghan MJ, Nihoyannopoulos P, Pandian NG, Pellikka PA, Pepi M, Roberson DA, Shernan SK, Shirali GS, Sugeng L, Ten Cate FJ, Vannan MA, Zamorano JL, Zoghbi WA. EAE/ASE Recommendations for image acquisition and display using three-dimensional echocardiography. J Am Soc Echocardiogr. 2012;25(1):3–46.
Mor-Avi V, Sugeng L, Lang R. Real time 3-dimensional echocardiography. An integral component of the routine echocardiographic examination in adult patients ? Circulation. 2009;119:314–29.
Pepi M, Tamborini G, Maltagliati A, et al. Head-to-head comparison of two- and three-dimensional transthoracic and transesophageal echocardiography in the localization of mitral valve prolapse. J Am Coll Cardiol. 2006;48(12):2524–30.
Perk G, Lang R, Garcia-Fernandez M, et al. Use of real-time three-dimensional echocardiography in intracardiac catheter based interventions. J Am Soc Echocardiogr. 2009;22:865–82.
Tamborini G, Ajmone Marsan N, Gripari P, Maffessanti F, Brusoni D, Muratori M, Caiani E, Fiorentini C, Pepi M. Reference values for right ventricular volumes and ejection fraction with real-time three-dimensional echocardiography: evaluation in a large series of normal subjects. J Am Soc Echocardiogr. 2010;23:109–15.
Tamborini G, Fusini L, Gripari P, Muratori M, Cefalù C, Maffessanti F, Alamanni F, Bartorelli A, Pontone G, Andreini A, Bertella E, Fiorentini C, Pepi M. Feasibility and accuracy of 3DTEE versus CT for the evaluation of aortic valve annulus to left main ostium distance before transcatheter aortic valve implantation. J Am Coll Cardiol Img. 2012;5:579–88.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Pepi, M., Tamborini, G. (2019). Three-Dimensional Echocardiography. In: Sarti, A., Lorini, F. (eds) Textbook of Echocardiography for Intensivists and Emergency Physicians. Springer, Cham. https://doi.org/10.1007/978-3-319-99891-6_5
Download citation
DOI: https://doi.org/10.1007/978-3-319-99891-6_5
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-99890-9
Online ISBN: 978-3-319-99891-6
eBook Packages: MedicineMedicine (R0)