Abstract
Total joint arthroplasties have increased significantly in number over the past several decades and appear to continue to increase exponentially in correlation with the demands of an aging population. The multifaceted approach to providing patients with a lasting implant is divided among the patient characteristics, surgical skills, and the biomaterials of the implant. The following chapter reviews the most commonly used biomaterials for total joint arthroplasty, their properties, their interaction with other implants, and the current progress in improving each material for greater stability, sterility, and survivability. This chapter also highlights the clinical relevance of these materials by presenting several case reports of failures of varying materials.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Koenig L, et al. Estimating the societal benefits of THA after accounting for work status and productivity: a Markov model approach. Clin Orthop Relat Res. 2016;474(12):2645–54.
Ruiz D Jr, et al. The direct and indirect costs to society of treatment for end-stage knee osteoarthritis. J Bone Joint Surg Am. 2013;95(16):1473–80.
Elmallah RK, et al. Determining cost-effectiveness of total hip and knee arthroplasty using the short form-6D utility measure. J Arthroplast. 2017;32(2):351–4.
Kurtz S, et al. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89(4):780–5.
Kurtz S, et al. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am. 2005;87(7):1487–97.
Kurtz SM, et al. International survey of primary and revision total knee replacement. Int Orthop. 2011;35(12):1783–9.
Neuprez A, et al. Patients’ expectations impact their satisfaction following total hip or knee arthroplasty. PLoS One. 2016;11(12):e0167911.
Lim JB, et al. Comparison of patient quality of life scores and satisfaction after common orthopedic surgical interventions. Eur J Orthop Surg Traumatol. 2015;25(6):1007–12.
Naal FD, et al. Clinical improvement and satisfaction after total joint replacement: a prospective 12-month evaluation on the patients’ perspective. Qual Life Res. 2015;24(12):2917–25.
Flego A, et al. Addressing obesity in the management of knee and hip osteoarthritis—weighing in from an economic perspective. BMC Musculoskelet Disord. 2016;17:233.
Gold HT, et al. Association of depression with 90-day hospital readmission after total joint arthroplasty. J Arthroplast. 2016;31(11):2385–8.
Bauer TW, Schils J. The pathology of total joint arthroplasty. II. Mechanisms of implant failure. Skeletal Radiol. 1999;28(9):483–97.
Blumenfeld TJ, Bargar WL. Early aseptic loosening of a modern acetabular component secondary to a change in manufacturing. J Arthroplast. 2006;21(5):689–95.
Bonsignore LA, Goldberg VM, Greenfield EM. Machine oil inhibits the osseointegration of orthopaedic implants by impairing osteoblast attachment and spreading. J Orthop Res. 2015;33(7):979–87.
Suhardi VJ, et al. A fully functional drug-eluting joint implant. Nat Biomed Eng. 2017;1.
McKee GK, Watson-Farrar J. Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br. 1966;48(2):245–59.
Charnley KEA. The classic: arthroplasty of hip: a new operation. Reprinted from Lancet pp. 1129–32, 1961. Clin Orthop Relat Res. 1973;95:4–8.
Bankston AB, et al. Comparison of polyethylene wear in machined versus molded polyethylene. Clin Orthop Relat Res. 1995;(317):37–43.
Faris PM, et al. Polyethylene sterilization and production affects wear in total hip arthroplasties. Clin Orthop Relat Res. 2006;453:305–8.
Rose RM, et al. On the origins of high in vivo wear rates in polyethylene components of total joint prostheses. Clin Orthop Relat Res. 1979;(145):277–86.
Landy MM, Walker PS. Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses. J Arthroplast. 1988;3(Suppl):S73–85.
Oonishi H, et al. Wear of highly cross-linked polyethylene acetabular cup in Japan. J Arthroplast. 2006;21(7):944–9.
Muratoglu OK, et al. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul award. J Arthroplast. 2001;16(2):149–60.
Muratoglu OK, et al. Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene. Clin Orthop Relat Res. 2003;(417):253–62.
Tower SS, et al. Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am. 2007;89(10):2212–7.
Birman MV, et al. Cracking and impingement in ultra-high-molecular-weight polyethylene acetabular liners. J Arthroplast. 2005;20(7 Suppl 3):87–92.
Oparaugo PC, et al. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature. Acta Orthop Scand. 2001;72(1):22–8.
Sochart DH. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop Relat Res. 1999;363:135–50.
Kurtz SM. UHMWPE biomaterials handbook : ultra-high molecular weight polyethylene in total joint replacement and medical devices. 3rd ed. Amsterdam; Boston: Elsevier/WA, William Andrew is an Imprint of Elsevier; 2016. xxiv, 815 pages.
Kurtz SM, et al. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials. 1999;20(18):1659–88.
Peacock AJ. Handbook of polyethylene. New York, NY: Marcel Dekker; 2000.
Callaghan JJ. The adult hip: hip arthroplasty surgery. 3rd ed. Philadelphia: Wolters Kluwer; 2016. 2 volumes (xxxi, 1490, 30 pages).
Oral E, et al. Diffusion of vitamin E in ultra-high molecular weight polyethylene. Biomaterials. 2007;28(35):5225–37.
Oral E, et al. Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E. J Arthroplast. 2006;21(4):580–91.
Oral E, et al. The effects of high dose irradiation on the cross-linking of vitamin E-blended ultrahigh molecular weight polyethylene. Biomaterials. 2008;29(26):3557–60.
Shareghi B, Johanson PE, Karrholm J. Wear of vitamin E-infused highly cross-linked polyethylene at five years. J Bone Joint Surg Am. 2017;99(17):1447–52.
Currently Available HXLPE Implants Available in the US, in Zimmer Longevity Highly Cross-linked Polyethylene: Clinical Value Dossier. 2012.
WILES P. The surgery of the osteoarthritic hip. Br J Surg. 1958;45(193):488–97.
Reed-Hill R. Physical metallury principles. 2nd ed. New York: Van Nostrand; 1973.
Kuhn AT. Corrosion of co-Cr alloys in aqueous environments. Biomaterials. 1981;2(2):68–77.
Fenske G. Ion implantation, in ASM handbook: friction, lubrication and wear technology, vol. 1992. Metals Park, OH: ASM International. p. 850.
Bunshah R. PVD and CVD coatings, in ASM handbook: friction, lubrication and wear technology, vol. 1992. Metals Park, OH: ASM International. p. 840.
Streicher RM, et al. New surface modification for Ti-6Al-7Nb alloy: oxygen diffusion hardening (ODH). Biomaterials. 1991;12(2):125–9.
Jones DM, et al. Focal osteolysis at the junctions of a modular stainless-steel femoral intramedullary nail. J Bone Joint Surg Am. 2001;83A(4):537–48.
Urban RM, et al. Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. J Bone Joint Surg Am. 1994;76(9):1345–59.
Jacobs JJ, et al. Local and distant products from modularity. Clin Orthop Relat Res. 1995;(319):94–105.
Gilbert J. Mechanically assisted corrosion of biomedical alloys. In: American Society for Materials Handbook, Corrosion 2006. Materials Park, OH: ASM International. p. 826–36.
Gilbert JL, et al. In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: emergent behavior in a new mechanism of in vivo corrosion. J Biomed Mater Res B Appl Biomater. 2012;100((2):584–94.
ASTM Annual Book of Standards. vol. 13. Philadelphia, PA: American Society for Testing and Materials; 1995.
Kwon YM, et al. Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours. J Bone Joint Surg Br. 2010;92(3):356–61.
Masonis JL, et al. Zirconia femoral head fractures: a clinical and retrieval analysis. J Arthroplasty. 2004;19(7):898–905.
Huot JC, et al. The effect of radiation dose on the tensile and impact toughness of highly cross-linked and remelted ultrahigh-molecular weight polyethylenes. J Biomed Mater Res B Appl Biomater. 2011;97((2):327–33.
Atwood SA, et al. Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene. J Mech Behav Biomed Mater. 2011;4(7):1033–45.
Hannouche D, et al. Ceramics in total hip replacement. Clin Orthop Relat Res. 2005;(430):62–71.
Jeffers JR, Walter WL. Ceramic-on-ceramic bearings in hip arthroplasty: state of the art and the future. J Bone Joint Surg Br. 2012;94(6):735–45.
Hamadouche M, et al. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84-A(1):69–77.
Wroblewski BM, et al. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg Br. 1996;78(2):280–5.
Wroblewski BM, Siney PD, Fleming PA. Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report. J Bone Joint Surg Br. 1999;81(1):54–5.
Wroblewski BM, Siney PD, Fleming PA. Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A 17-year follow-up report. J Bone Joint Surg Br. 2005;87(9):1220–1.
Allain J, et al. Poor eight-year survival of cemented zirconia-polyethylene total hip replacements. J Bone Joint Surg Br. 1999;81(5):835–42.
De Aza AH, et al. Crack growth resistance of alumina, zirconia and zirconia toughened alumina ceramics for joint prostheses. Biomaterials. 2002;23(3):937–45.
Chevalier J. What future for zirconia as a biomaterial? Biomaterials. 2006;27(4):535–43.
Tribe H, et al. Advanced wear of an Oxinium™ femoral head implant following polyethylene liner dislocation. Ann R Coll Surg Engl. 2013;95(8):e133–5.
Hernigou P, Mathieu G, Poignard A. Oxinium, a new alternative femoral bearing surface option for hip replacement. Eur J Orthop Surg Traumatol. 2007;17(3):243–6.
Kop AM, Whitewood C, Johnston DJ. Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation three retrieval case studies. J Arthroplasty. 2007;22(5):775–9.
Walter WL, et al. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty. 2004;19(4):402–13.
Jarrett CA, et al. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91(6):1344–9.
Mai K, et al. Incidence of ‘squeaking’ after ceramic-on-ceramic total hip arthroplasty. Clin Orthop Relat Res. 2010;468(2):413–7.
Swanson TV, et al. Influence of prosthetic design on squeaking after ceramic-on-ceramic total hip arthroplasty. J Arthroplast. 2010;25(6 Suppl):36–42.
Kiyama T, Kinsey TL, Mahoney OM. Can squeaking with ceramic-on-ceramic hip articulations in total hip arthroplasty be avoided? J Arthroplast. 2013;28(6):1015–20.
Restrepo C, et al. The noisy ceramic hip: is component malpositioning the cause? J Arthroplast. 2008;23(5):643–9.
Stanat SJ, Capozzi JD. Squeaking in third- and fourth-generation ceramic-on-ceramic total hip arthroplasty: meta-analysis and systematic review. J Arthroplasty. 2012;27(3):445–53.
Currier SF, Mautner HG. On the mechanism of action of choline acetyltransferase. Proc Natl Acad Sci U S A. 1974;71(9):3355–8.
Chevillotte C, et al. The 2009 frank Stinchfield award: “hip squeaking”: a biomechanical study of ceramic-on-ceramic bearing surfaces. Clin Orthop Relat Res. 2010;468(2):345–50.
Chevillotte C, et al. Hip squeaking: a 10-year follow-up study. J Arthroplast. 2012;27(6):1008–13.
Kurtz SM, et al. Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Clin Orthop Relat Res. 2013;471(10):3270–82.
Gill IP, et al. Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation. J Bone Joint Surg Br. 2012;94(7):895–900.
Chana R, et al. Mixing and matching causing taper wear: corrosion associated with pseudotumour formation. J Bone Joint Surg Br. 2012;94(2):281–6.
Hallab NJ, et al. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res. 2004;22(2):250–9.
Urish KL, et al. Trunnion failure of the recalled low friction ion treatment cobalt chromium alloy femoral head. J Arthroplast. 2017;32(9):2857–63.
Patel S, Talmo CT, Nandi S. Head-neck taper corrosion following total hip arthroplasty with Stryker meridian stem. Hip Int. 2016;26(6):e49–51.
Gührs J, et al. The influence of stem taper re-use upon the failure load of ceramic heads. Med Eng Phys. 2015;37(6):545–52.
MacDonald DW, et al. Fretting and corrosion damage in taper adapter sleeves for ceramic heads: a retrieval study. J Arthroplast. 2017;32(9):2887–91.
Esposito CI, et al. What is the trouble with trunnions? Clin Orthop Relat Res. 2014;472(12):3652–8.
Jack CM, et al. The use of ceramic-on-ceramic bearings in isolated revision of the acetabular component. Bone Joint J. 2013;95-B(3):333–8.
Thorey F, et al. Early results of revision hip arthroplasty using a ceramic revision ball head. Semin Arthroplast. 2011;22:284–9.
Acknowledgements
The authors would like to acknowledge Dr. Adam Klein and Dr. Ryan Murphy for sharing their expertise and experiences. The authors would also like to thank Suzanne Danley for her critical review and editing. The work reported in this publication was supported by the National Institute of General Medical Sciences of the National Institutes of Health under Award Number 2U54GM104942-02. The Content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
1 Electronic Supplementary Material
Caption (MP4 9734 kb)
Caption (MP4 20915 kb)
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG, part of Springer Nature
About this chapter
Cite this chapter
Bravin, L.N., Dietz, M.J. (2018). Biomaterials in Total Joint Arthroplasty. In: Li, B., Webster, T. (eds) Orthopedic Biomaterials . Springer, Cham. https://doi.org/10.1007/978-3-319-89542-0_9
Download citation
DOI: https://doi.org/10.1007/978-3-319-89542-0_9
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-89541-3
Online ISBN: 978-3-319-89542-0
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)