Abstract

The main hurdle to clogging diagnosis lies in the difficulty to access the inside of steam generators and the absence of internal sensors. These issues are addressed in different manners by diagnosis methods that are used for routine monitoring or occasional assessment of a steam generators “health”. Monitoring devices can be inserted through the upper openings of the steam generators and allow to inspect their upper support plate. The vertical repartition of clogging can be estimated using the signals of the eddy current probes used for crack detection. These two methods were recently complemented by the monitoring in steady states of the wide range level, the pressure difference between the top and the bottom of the steam generator, which is impacted by the additional pressure drop induced by clogging. The new diagnosis methodology presented in this book relies on the analysis of the dynamic response of the wide range level during power transients.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 16.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Barbe V, Dumay D (2012) évaluation du colmatage des plaques entretoises—bilan des connaissances sur les procédés par sonde interne. Technical Report, EDEECE110317/A, EDF

    Google Scholar 

  • Bernier V (2007) Impact du colmatage sur les paramètres de fontionnement des GV 51B sur la base du modèle monodimensionnel de générateurs de vapeur de remplacement du palier 900 MWe. Technical Report, ANREEC070136/A, EDF

    Google Scholar 

  • Carradec R (2011) CNPE de Bechet—tranche 1; Expertises télévisuelles réalisées sur la plaque entretoise 9 (PE8) du GV 2 (no208)—VD3 2011. Techical Report, EDIAT110460/A, EDF

    Google Scholar 

  • Cheong YM, Chaudary MS, Edwards P, Grosser P, Rodda J, Khan AA (2011) Eddy Current Testing at Level 2: manual for the Syllabi Contained in IAEA-TECDOC-628.Rev. 2 “Training Guidelines for Non Destructive Testing Techniques”. IAEA

    Google Scholar 

  • Chip V, Midou M, Favennec JM, Siros F (2008) étude d’estimation du colmatage par traitement des données de process sur un modèle physique de GV. Technical Report, H-P1B-2009-03213, EDF

    Google Scholar 

  • Chip V, Midou M (2009) Approche stochastique pour l’estimation du colmatage des générateurs de vapeur d’une centrale nucléaire. Technical Report, H-P1B-2009-02146, EDF

    Google Scholar 

  • Crinon R (2009) évaluation de l’efficacité des NCGV 2007–2008 sur la performance des GV. Technical Report, D4550.31-09/2003, EDF

    Google Scholar 

  • de Bouvier P Odile adn Méquies (2007) Avis technique CEIDRE : évaluation du colmatage résiduel des plaques entretoises des GV de Coltrane 2 après nettoyage chimique (octobre 2007). Technical Report, EDEDFM070308/A, EDF

    Google Scholar 

  • Devinck JM (2009) Mode opératoire appliqué pour la détermination de l’indicateur SAX lié au colmatage sur les plaques entretoises quadrifoliées des GV 51B, 51 BI et 68/19. Technical Report, EDEECE080127/B, EDF

    Google Scholar 

  • Gay A, Midou M, Favennec JM, Ninet J (2009) Rapport de stage d’Aurélien Gay sur l’étude d’estimation du colmatage par traitement des données process sur un modèle physique de GV. Technical Report, H-P1B-2009-02094, EDF

    Google Scholar 

  • Ghattas S, Blanc JM (1987) EP RGL 4—Essai périodiques de calibrage des grappes grises. Technical Report, EP/NE/DC.0476, EDF/Framatome

    Google Scholar 

  • Girard S (2012) Diagnostic du colmatage des générateurs de vapeur à l’aide de modèles physiques et statistiques. Ph. D. thesis, École des Mines ParisTech

    Google Scholar 

  • Idel’cik IE (1969) Memento des Pertes de Charge—Coefficients de Pertes de Charge Singulières et de Pertes de Charge par Frottement. Collection de la Direction des Études d’Électricité de France, Édition Eyrolles, traduit du russe

    Google Scholar 

  • Midou M, Ninet J, Favennec JM, Gay A, Chip V (2010a) Estimation du colmatage des générateurs de vapeur de type 51b et 47/22 : méthode du NGL dynamique. Technical Report, H-P1B-2009-03213, EDF

    Google Scholar 

  • Midou M, Ninet J, Girard A, Favennec JM (2010b) Estimation of SG TSP blockage: innovative monitoring through dynamic behavior analysis. In: 18th International Conference on Nuclear Engineering (ICONE18)

    Google Scholar 

  • Monchecourt D (2011) Méthodologie d’évaluation du taux de réduction de section des passages foliés en PE 9 des GV de type 68/19. Technical Report, EDIAT110416/A, EDF

    Google Scholar 

  • Ninet J, Favennec JM, Larrignon G (2010) Estimation du taux de colmatage des générateurs de vapeur par analyse du comportement dynamique du NGL : étude de faisabilité concernant l’applicabilité de la méthode aux tranches REP hors EDF. (étude réalisée pour l’EPRI). Technical Report, H-P1C-2010-03382-EN, EDF

    Google Scholar 

  • Ninet J, Deneux O, Girard S (2012) Évaluation du colmatage par la méthode du NGL dynamique: validation et application au parc de GV 51B, 51BI et 47/22. Technical Report, H-P1C-2012-00688-FR, EDF

    Google Scholar 

  • Ninet J, Favennec JM (2010) Determination of applicability of EDF steam generator monitoring algorithm to pressurized water reactors worldwide. Technical Report, 1021079, EPRI

    Google Scholar 

  • Pigeon L (1997) Dossier de spécifications de l’intrégration de l’EP RGL4 dans SAPEC : calibrage des grappes grises. Technical Report, HP-13/97/019/A, EDF

    Google Scholar 

  • Pillet J, Nimambeg N, Pinto C (2010) Résultats des essais monophasiques sur la maquette P2C pour la détermination des pertes de charge induites par le colmatage. Technical Report, H-I84-2009-02838, EDF

    Google Scholar 

  • Stindel M (2007) Méthode d’évaluation par examen télévisuel du taux de colmatage de la plaque entretoise supérieure des GV 900 MW: evolutions, incertitudes et retour d’éxpérience. Technical Report, EDIAT070539, EDF

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sylvain Girard .

Rights and permissions

Reprints and permissions

Copyright information

© 2014 The Author(s)

About this chapter

Cite this chapter

Girard, S. (2014). State of the Art of Clogging Diagnosis. In: Physical and Statistical Models for Steam Generator Clogging Diagnosis. SpringerBriefs in Applied Sciences and Technology. Springer, Cham. https://doi.org/10.1007/978-3-319-09321-5_3

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-09321-5_3

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-09320-8

  • Online ISBN: 978-3-319-09321-5

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics