Impedance cardiography (ICG) allows to measure parameters of heart mechanical function. ICG is sensitivity to movement artifacts inter alia breathing, which distorts impedance signal. Several methods were proposed to eliminate this distortion, but they cannot be used to continuous measurement or do not remove movement artifact. Adaptive filter is event-related, it learns signal characteristic within the cycle and removes components uncorrelated with the event. In this study, we compared ICG signal obtained during normal breathing with that after adaptive filtration and ICG signal obtained during momentary breath holding with this signal processed with adaptive filter. We conclude that adaptive filtering may help extract information from noisy and distorted ICG signal, but on the other hand, it may obscure some real changes in signal, for instance, rapid cyclic changes connected with respiration.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Cybulski, G.: Ambulatory impedance cardiography. In: Ambulatory Impedance Cardiography, pp. 39–56. Springer, Berlin, Heidelberg (2011)
Patterson, R.P.: Sources of the thoracic cardiogenic electrical impedance signal as determined by a model. Med. Biol. Eng. Compu. 23(5), 411–417 (1985)
Patterson, R.P.: Impedance cardiography: what is the source of the signal?. J Phys: Conf. Ser 224(1). IOP Publishing (2010)
Siebert, J., Wtorek, J.: Impedance cardiography. The early diastolic phase of heart Chambers feeling—O dZ/dt (in Polish). Ann. Acad. Gedan. 27, 79–89 (1993)
Denniston, J.C., et al.: Measurement of cardiac output by electrical impedance at rest and during exercise. J. Appl. Physiol. 40(1), 91–95 (1976)
Miyamoto, Y., et al.: Continuous determination of cardiac output during exercise by the use of impedance plethysmography. Med. Biol. Eng. Compu. 19(5), 638–644 (1981)
Yamamoto, Y., et al.: Design and implementation of a digital filter for beat-by-beat impedance cardiography. IEEE Trans. Biomed. Eng. 35(12), 1086–1090 (1988)
Laguna, P., et al.: Adaptive filter for event-related bioelectric signals using an impulse correlated reference input: comparison with signal averaging techniques. IEEE Trans. Biomed. Eng. 39(10), 1032–1044 (1992)
Barros, A.K., et al.: Filtering noncorrelated noise in impedance cardiography. IEEE Trans. Biomed. Eng. 42(3), 324–327 (1995)
Guz, A., et al.: Respiratory modulation of left ventricular stroke volume in man measured using pulsed Doppler ultrasound. J. Physiol. 393(1), 499–512 (1987)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Żyliński, M., Wojciechowska, M., Niewiadomski, W., Sadowiec, M., Borodzicz, S., Cybulski, G. (2020). Adaptive Filter Removes Variability Caused by Respiration from Impedance Cardiography Signal. In: Badnjevic, A., Škrbić, R., Gurbeta Pokvić, L. (eds) CMBEBIH 2019. CMBEBIH 2019. IFMBE Proceedings, vol 73. Springer, Cham. https://doi.org/10.1007/978-3-030-17971-7_1
Download citation
DOI: https://doi.org/10.1007/978-3-030-17971-7_1
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-17970-0
Online ISBN: 978-3-030-17971-7
eBook Packages: EngineeringEngineering (R0)