Adaptive Filter Removes Variability Caused by Respiration from Impedance Cardiography Signal

  • Conference paper
  • First Online:
CMBEBIH 2019 (CMBEBIH 2019)

Part of the book series: IFMBE Proceedings ((IFMBE,volume 73))

Included in the following conference series:

  • 2278 Accesses

Abstract

Impedance cardiography (ICG) allows to measure parameters of heart mechanical function. ICG is sensitivity to movement artifacts inter alia breathing, which distorts impedance signal. Several methods were proposed to eliminate this distortion, but they cannot be used to continuous measurement or do not remove movement artifact. Adaptive filter is event-related, it learns signal characteristic within the cycle and removes components uncorrelated with the event. In this study, we compared ICG signal obtained during normal breathing with that after adaptive filtration and ICG signal obtained during momentary breath holding with this signal processed with adaptive filter. We conclude that adaptive filtering may help extract information from noisy and distorted ICG signal, but on the other hand, it may obscure some real changes in signal, for instance, rapid cyclic changes connected with respiration.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Cybulski, G.: Ambulatory impedance cardiography. In: Ambulatory Impedance Cardiography, pp. 39–56. Springer, Berlin, Heidelberg (2011)

    Chapter  Google Scholar 

  2. Patterson, R.P.: Sources of the thoracic cardiogenic electrical impedance signal as determined by a model. Med. Biol. Eng. Compu. 23(5), 411–417 (1985)

    Article  Google Scholar 

  3. Patterson, R.P.: Impedance cardiography: what is the source of the signal?. J Phys: Conf. Ser 224(1). IOP Publishing (2010)

    Google Scholar 

  4. Siebert, J., Wtorek, J.: Impedance cardiography. The early diastolic phase of heart Chambers feeling—O dZ/dt (in Polish). Ann. Acad. Gedan. 27, 79–89 (1993)

    Google Scholar 

  5. Denniston, J.C., et al.: Measurement of cardiac output by electrical impedance at rest and during exercise. J. Appl. Physiol. 40(1), 91–95 (1976)

    Article  Google Scholar 

  6. Miyamoto, Y., et al.: Continuous determination of cardiac output during exercise by the use of impedance plethysmography. Med. Biol. Eng. Compu. 19(5), 638–644 (1981)

    Article  Google Scholar 

  7. Yamamoto, Y., et al.: Design and implementation of a digital filter for beat-by-beat impedance cardiography. IEEE Trans. Biomed. Eng. 35(12), 1086–1090 (1988)

    Article  Google Scholar 

  8. Laguna, P., et al.: Adaptive filter for event-related bioelectric signals using an impulse correlated reference input: comparison with signal averaging techniques. IEEE Trans. Biomed. Eng. 39(10), 1032–1044 (1992)

    Article  Google Scholar 

  9. Barros, A.K., et al.: Filtering noncorrelated noise in impedance cardiography. IEEE Trans. Biomed. Eng. 42(3), 324–327 (1995)

    Article  Google Scholar 

  10. Guz, A., et al.: Respiratory modulation of left ventricular stroke volume in man measured using pulsed Doppler ultrasound. J. Physiol. 393(1), 499–512 (1987)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marek Żyliński .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Żyliński, M., Wojciechowska, M., Niewiadomski, W., Sadowiec, M., Borodzicz, S., Cybulski, G. (2020). Adaptive Filter Removes Variability Caused by Respiration from Impedance Cardiography Signal. In: Badnjevic, A., Škrbić, R., Gurbeta Pokvić, L. (eds) CMBEBIH 2019. CMBEBIH 2019. IFMBE Proceedings, vol 73. Springer, Cham. https://doi.org/10.1007/978-3-030-17971-7_1

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-17971-7_1

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-17970-0

  • Online ISBN: 978-3-030-17971-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics