Abstract

The use of focused ion beams (FIB) in the field of electron microscopy for the preparation of site specific samples and for imaging has become very common. Site specific sample preparation of cross-section samples is probably the most common use of the focused ion beam tools, although there are uses for imaging with secondary electrons produced by the ion beam. These tools are generally referred to as FIB tools, but this name covers a large range of actual tools. There are single beam FIB tools which consist of the FIB column on a chamber and also the FIB/SEM platforms that include both a FIB column for sample preparation and an SEM column for observing the sample during preparation and for analyzing the sample post-preparation using all of the imaging modalities and analytical tools available on a standard SEM column. A vast majority of the FIB tools presently in use are equipped with liquid metal ion sources (LMIS) and the most common ion species used is Ga. Recent developments have produced plasma sources for high current ion beams. The gas field ion source (GFIS) is discussed in module 31 on helium ion microscopy in this book.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  • Giannuzzi L, Michael J (2013) Comparison of channeling contrast between ion and electron images. Microsc Microanal 19:344

    Article  CAS  Google Scholar 

  • Giannuzzi L et al (2006) Introduction to focused ion beams: instrumentation, theory, techniques and practice. Springer Science & Business Media, New York

    Google Scholar 

  • Joy D, Michael J (2014) Modeling ion-solid interactions for imaging applications. MRS Bulletin 39:342

    Google Scholar 

  • Kotula P, Keenan M, Michael J (2006) Tomographic spectral imaging with multivariate statistical analysis: comprehensive 3D microanalysis. Microsc Microanal 12:36

    Google Scholar 

  • Mayer J, Giannuzz LA, Kamino T, Michael J (2007) TEM sample preparation and FIB-induced damage. MRS bulletin 32(05):400–407

    Article  CAS  Google Scholar 

  • Michael J (2011) Focused ion beam-induced microstructural alterations: texture development, grain growth, and intermetallic formation. Microsc Microanal 17:386

    Article  CAS  Google Scholar 

  • Nastasi M, Mayer J, Hirvonen J (1996) Ion-solid interactions: fundamentals and applications. Cambridge University Press, Cambridge

    Google Scholar 

  • Orloff J, Swanson L, Utlaut M (1996) Fundamental limits to imaging resolution for focused ion beams. J Vac Sci Technol B 14:3759

    Google Scholar 

  • Orloff J, Swanson L, Utlaut M (2003) High resolution focused ion beams: FIB and its applications: Fib and its applications: the physics of liquid metal ion sources and ion optics and their application to focused ion beam technology. Springer Science & Business Media, New York

    Google Scholar 

  • Prasad S, Michael J, Christenson T (2003) EBSD studies on wear-induced subsurface regions in LIGA nickel. Scr Mater 48:255

    Article  CAS  Google Scholar 

  • Ziegler J, Biersack J (1985) The stopping and range of ions in matter. In: Treatise on heavy-ion science. Springer US, New York, pp 93–129

    Chapter  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Science+Business Media LLC

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Goldstein, J.I., Newbury, D.E., Michael, J.R., Ritchie, N.W.M., Scott, J.H.J., Joy, D.C. (2018). Focused Ion Beam Applications in the SEM Laboratory. In: Scanning Electron Microscopy and X-Ray Microanalysis. Springer, New York, NY. https://doi.org/10.1007/978-1-4939-6676-9_30

Download citation

Publish with us

Policies and ethics