Abstract
Engineering structures are generally designed as the assembly of several parts in consideration of manufacture and structural strength, while different connections have great effects on the dynamic characteristics of the whole structure. This article firstly introduces the influence of stiffness and mass distribution on the beam’s modal parameters. Then a beam-like structure consisting of four steel parts connected with bolts is presented and a series of modal testing is performed to estimate the modal parameters under free-free boundary condition. Afterwards connection location and bolt preload are selected as variables for modal testing, and the modal parameters of the beam-like structure with different connection locations and bolt preloads are compared. Finally, the finite element model of the bolted connection is updated based on the data of modal testing. The results indicate that the larger bolt preload increases the stiffness of connections, which consequently changes the modal parameters, while the influence of the bolt preload highly depends on the connection location.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Heylen W, Lammens S, Sas P (2007) Modal analysis theory and testing. Katholieke University Leuven, Leuven
Song Y, Hartwigsen CJ et al (2004) Simulation of dynamics of beam structures with bolted joints using adjusted Iwan beam elements. J Sound Vib 273:249–276
Ibrahim RA, Pettit CL (2005) Uncertainties and dynamic problems of bolted joints and other fasteners. J Sound Vib 279(3–5):857–936
Ouyang H, Oldfield MJ et al (2006) Experimental and theoretical studies of a bolted joint excited by a torsional dynamic load. Int J Mech Sci 48:1447–1455
Ahmadian H, Ebrahimi M et al (2002) Identification of bolted-joint interface models. In: Proceedings of ISMA 2002: International Conference on Noise and Vibration Engineering, Katholieke University, Leuven, Belgium, pp. 1741–1747
Xiang Zheng, Weiming Xia (2009) Numerical simulation of blind hole bolt connection with 3-D finite element approach. In: Proceedings of the Second International Conference on Information and Computing Science, ICIC 2009, Manchester, vol 4, pp.164–169
Ahmadian H, Jalali H (2007) Identification of bolted lap joints parameters in assembled structures. Mech Syst Signal Process 21:1041–1050
Clough R, Penzien J (1995) Dynamics of structures. Computers & Structures, Berkeley
Mottershead JE, Friswell MI (1993) Model updating in structural dynamics: a survey. J Sound Vib 167(2):347–375
Chen JC, Garba JA (1980) Analytical model improvement using modal test results. J AIAA 18(6):684–690
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 The Society for Experimental Mechanics, Inc.
About this paper
Cite this paper
Ma, ZS., Liu, L., Zhou, SD., Jiang, D., He, YY. (2013). Effects of Bolted Connection on Beam Structural Modal Parameters. In: Cunha, A. (eds) Topics in Dynamics of Bridges, Volume 3. Conference Proceedings of the Society for Experimental Mechanics Series. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-6519-5_15
Download citation
DOI: https://doi.org/10.1007/978-1-4614-6519-5_15
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4614-6518-8
Online ISBN: 978-1-4614-6519-5
eBook Packages: EngineeringEngineering (R0)