Abstract
Treatment planning systems are computer software trying to predict the real dose absorbed by the patient using experimental data. Technologic progress in recent years has made it possible to obtain planning techniques for high-dose gradients by using inverse planning techniques. Obtained doses from three dimensional conformal radiotherapy (3D-CRT) can be validated by calculation of doses at different points. However, more knowledge and skill are expected from intensity modulated radiotherapy (IMRT) planning systems. Unlike the 3D-CRT, the IMRT field is made of many small, asymmetrical and irregular subfields. Subfields correctively obtained as a result of leaf positions are more important than in 3D-CRT. As subfields are created with multileaf collimators, naturally, accuracy of the multileaf collimator becomes more important. Multileaf collimator positioning error in IMRT causes worse results than in 3D-CRT. Furthermore, leaf transmission, output linearity, and similar data affect IMRT results much more than 3D-CRT results. Therefore, medical physicists must check the reality of results predicted by the planning system and each clinic must have its own specific quality assurance (QA) procedure [1].
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Palta JR, Lıu C, Lı JG. Quality assurance of intensity modulated radiation therapy. Department of Radiation Oncology, University of Florida, Gainesville, FL. Int J Radiat Oncol Biol Phys. 2008;71(1 Suppl):S108–12.
Michael B. Sharpe Commissioning and quality assurance for IMRT treatment planning. In: Intensity-Modulated Radiation Therapy: The State of Art. 1st ed. American Association of Physicists in Medicine; 2003. p. 449–75.
Alber M, Broggi S, Wagter CD, et al. ESTRO Booklet No.9: guidelines for the verification of IMRT. 1st ed. Brussels: ESTRO; 2008. p. 1–16.
Xia P, Chuang C. Patient-specific quality assurance in IMRT. In: Intensity-modulated radiation therapy: the state of art. 1st ed. American Association of Physicists in Medicine; 2003. p. 495–515.
De Wagter C. The ideal dosimeter for intensity modulated radiation therapy (IMRT): what is required? (DOSGEL2004, Ghent, Belgium). J Phys Conf Ser. 2004;3:4–8.
Wagter CD. QA-QC of IMRT—European perspective. In: Bortfeld T, Schmidt-Ullrich R, Neve WD, Wazer DE, editors. Image-guided IMRT. Berlin: Springer; 2006. p. 117–28.
Klein EE, Hanley J, Bayouth J, et al. Task Group 142 report: quality assurance of medical acceleratos. Med Phys. 2009;36(9):4197–212.
LoSasso TJ. IMRT delivery system QA. In: Intensity-modulated radiation therapy: The State of Art. 1st ed. American Association of Physicists in Medicine; 2003. p. 561–93.
Chui CS, Spirou S, LoSasso T. Testing of dynamic multileaf collimation. Med Phys. 1996;23:635–41.
Boyer A, Biggs P, Galvin J, et al. Applications of Multileaf Collimators: Report of the AAPM Radiation Therapy Committee Task Group No. 50. AAPM Report No. 72. Madison, WI: Medical Physics Publishing; 2001.
Hwang I-M, Wu J, Chuang K-S, Ding H-J. An alternative effective method for verifying the multileaf collimator leaves speed by using a digital-video imaging system. J Nima. 2010;623:867–71.
Kiran F, Erturk ME, Yolcu T. Evaluation of multileaf collimator speed in dinamic IMRT. In: 13th Meeting of the National Medical Physics Education Book. November 17–19 2011, Cesme, Izmir, Turkey; 2011. p. 124.
Ezzell GA, Burmeister JW, Nesrin D, et al. IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys. 2009;36(11):5359–73.
Nelms B, Simon W, Jursinic P. “Verification of IMRT delivery using a 2-D diode array and analysis software”, Abstract. Med Phys. 2002;29(6):1364.
Low DA, Harms WB, Mutic S. A technique for the quantitative evaluation of dose distributions. Med Phys. 1998;25:656–61.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer Science+Business Media New York
About this chapter
Cite this chapter
Atamel, M., Erturk, E. (2013). Quality Assurance. In: Haydaroglu, A., Ozyigit, G. (eds) Principles and Practice of Modern Radiotherapy Techniques in Breast Cancer. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-5116-7_20
Download citation
DOI: https://doi.org/10.1007/978-1-4614-5116-7_20
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4614-5115-0
Online ISBN: 978-1-4614-5116-7
eBook Packages: MedicineMedicine (R0)